consumers l\\3awer POWERINli lllllCHlliAN"S PRDliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-1636 January 12, 1988 Nuclear Regulatory Comniission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
Kenneth W Berry Director Nuclear Licensing RESPONSE TO NRC COMPLIANCE BULLETIN 87 FASTENER TESTING TO DETERMINE CONFORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS Nuclear Regulatory Commission letter dated November 6, 1987 transmitted NRC Compliance Bulletin 87-02, Fastener Testing to Determine Conformance with Applicable MateriaJ. Specifi_cations and required a response within 60 days of receipt of the bulletin.
Specifically, Consumers Power Company was required t.6 review rec"eipt inspection "requirements and internal controls for fasteners and to independently determine, through testing, whether fasteners in stores meet mechanical and chemical specific~tion requirements.
Our response for Palisades is provided herein.
Item 1 Describe a) the characteristics currently examined during receipt inspection of fasteners (i.e., head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance), and b) internal controls utilized during storage and issuance from stock to assure the appropriate use of fasteners.
Response
a)
Receipt Inspection Receipt inspection is done only on "Q" procurements, therefore, characteristics other than quantity or shipping damage are not checked on "non-Q" receipts.
For "Q" procurements, characteristics inspected are those which are specified on the purchase order, such as dimensions, required documentation or packaging.
Dimensional inspection would normally verify length, diameter and threads per inch.
Required documentation would usually include a certificate of conformance, but would rarely require a material test report.
In addition to what the purchase order specifies, markings are verified to match the ASTM, ASME or SAE specifications of the purchase order.
OC0188-0002-NL02-NL04 8801190061 880112
-se
~\\
PDR ADOCK 05000255 Q
(
Nuclear Regulatory Co!.ssion Palisades Plant Response to NRC Compliance Bulletin 87-02 Date b)
Storage and Issue 2
Both "Q" and "non-Q" fasteners are stored in essentially identical environ-ments but are physically separated per ANSI requirements.
All fasteners are stored in a dry, heated warehouse.
They are not stored by size or dimension.
When they have a single application (control rod drive, feed pump casing, etc), they may be stored with the other basic component parts to which they apply.
The storage location (shelf, cabinet, drawer) is indexed by assigned stock numbers.
Fasteners are not individually wrapped, rather, they are packaged (usually in a clear plastic bag) by purchase order number.
For "Q" fasteners, the packages are tagged to identify the purchase order number; for "non-Q" packages they are not generally tagged.
There is a third category of fast;ener and that is a "non-Q" general use or bulk supply.
These fasteners are not assigned stock numbers and are stored in bins or trays by size.
These are hardware store variety fasteners.
"Q" and "non-Q" items with stock numbers are issued in accordance with the similar controls.
That is, they are issued to a work document governing and detailing the work being done.
"Q" items are not issued in bulk; "non-Q" items may be if requested.
For "Q" issued material, trac.eability exists from the purchase order to the item end use. or from the end use back to the purchase -order.
For the "non-Q" ~aterial, with stock numbers, traceability only exists to the stock number and not to a specific purchase order.
For "non-Q" fasteners without stock numbers, there are minimal controls.
They are not issued with issue tickets, there are no records of end use and bulk issue for shop use or shop supplies is permitted.
There is no traceability from purchase order to use or any other material control requirements imposed on their issue.
Item 2 Select a minimum sample of ten (10) non-safety related fasteners (studs, bolts, and/or cap screws), and ten (10) safety-related fasteners (studs, bolts, and/or cap screws) from current, in use, stock.
The sample is to be obtained by the licensee with the participation of an NRC inspector.
Fasteners procured to meet the following chemical and mechanical properties are of interest:
A-193 grades B7, B8, and B16; SAE J429 grades 5 and 8; A-449; A-325 Types 1, 2 or 3; A-354 grades BB, BC, BD; A-490; A-320 LTM; A-307; A-563; or equivalent.
OC0188-0002-NL02-NL04
e Nuclear Regulatory Commission Palisades Plant Response to NRC Compliance Bulletin 87-02 Date
Response
The samples were obtained in late November with the participation of the 3
senior site resident inspector, taking into account those fasteners of interest.
Refer to Attachment 1 which contains the fastener testing data sheets and which contains vendor data, mechanical, and chemical test data.
Pages 1 to 2A of Attachment 2 are safety-related samples; pages 3 and 3A are non-safety related samples.
Item 3 For the selected sample of fasteners in item 2, include a sample of typical nuts that would be used with each fastener (one-for-one).
In particular, nuts purchased to the chemical and mechanical specifications of A-194 are of interest.
Response
Typical nuts were obtained with the participation of the senior site resident inspector; using the same selection criteria as that for the fasteners (see ).
Item 4 Chemical testing shall be performed on all samples.
Mechanical testing shall be performed on each safety-related fastener.
Hardness testing shall be performed on each nut and non-safety-related fastener.
All testing shall be performed by a laboratory which the licensee has qualified for this type of testing and appears on the licensee's approved vendor list. Testing performed shall be done in accordance with the requirements of the fastener's specifi-cation, grade, and class, and the test shall evaluate the ultimate tensi.le strength, hardness and chemical properties as required by the fastener's specification, grade, and class.
Each sample shall be tagged with the sample's ID number.
Response
Chemical, mechanical, and hardness testing results are provided in.
Testing was performed in accordance with the requirements of the samples' specifications.
Mechanical and hardness testing was performed by Consumers Power Company Laboratory Services Dept.
Chemical testing was performed by Chicago Spectra Service Laboratory of Chicago, IL.
Both testing laboratories are qualified by Consumers Power Company.
OC0188-0002-NL02-NL04
e Nuclear Regulatory Commission Palisades Plant Response to NRC Compliance Bulletin 87-02 Date Item 5 4
The result.s of all tests, together with supporting information, are to be reported to the NRC utilizing the format shown in Attachments 1 and 2 of this bulletin.
Include the names and addresses of suppliers and manufacturers of safety-related fasteners and, to the extent possible, of non-safety-related fasteners.
For any fastener found out of specification, provide an evaluation of the safety significance including consideration of the most limiting application.
Response
The results of the tests conducted are included in Attachment 2.
Three fasteners (PAL-10, -5, and -43) were found to be out-of-specification. All three fasteners had hardness values out-of-specification.
One safety-related stud, sample PAL-10, had a Rockwell C hardness value of approximately 41 HRC as compared to the accepted range of values of 24 to. 37 HRC.
Although this hardness value is slightly out of range, the results of the mechanical testing showed the ultimate tensile strength, yield strength, percent elongation and reduction area percent to be within the minimum values.
Also the results of the chemical anl~ysis showed the stud to be in specification.
We, therefore, find this stud to be of acceptable quality and *conclude there is no safety signifi~ance associated with its use or other studs from the same batch.
Only one other stud.procurred with sample PAL-10 is presently. in use and it is in a non-safety related application.
The two non-safety related bolts, samples PAL-5 and PAL-43, had Rockwell C hardness values which were slightly lower than the minimum required value of 25 HRC.
The test values of 24.6 and 23.9, respectively, are the average of five tests.
Although no mechanical testing was conducted, the chemical testing for these bolts showed them to meet the specification requirements.
From ASTM A-370, it can be seen that the approximate tensile strength for 24 HRC is 119 ksi.
This nearly equals the required minimum tensile require-ments of 120 ksi for the bolt specifications.
Although only an approximation, this does provide additional assurance of the bolts' strength.
Since these bolts are used in non-safety related applications, there is no safety signifi-cance in the use of these bolts or others from the same batches.
Item 6 Based on the results of the testing and review of current procedures, describe any further actions being taken to assure that fasteners used in the plant meet the requisite specifications and requirements and that the operability of safety-related plant components is not affected.
OC0188-0002-NL02-NL04
1 e
Nuclear Regulatory Commission Palisades Plant Response to NRC Compliance Bulletin 87-02 Date
Response
5 Testing results did not identify any signific~nt anomalies.
Deviations from specifications are slight and most likely attributed to natural variations in chemistry, heat treatment, and testing. Results did not indicate that any of fastener components were mis-marked or found to be traceable to lesser strength specifications.
No further actions were determined to be necessary.
Following NRC evaluation of the responses from all licensees, Consumers Power Company requests that they be informed of any suppliers or manufactures which evidence poor performance so that we may evaluate their acceptability for future procurements.
Kenneth W Berry Director, Nuclear Licensing CC Administrator, Region III, ~C NRC Resident Inspector - Palisades Attachment OC0188-0002-NL02-NL04
CONSUMERS POWER COMPANY Palisades Plant Docket 50-255 - License DPR-20 RESPONSE TO NRC COMPLIANCE BULLETIN 87-02 At the request of the Commission and pursuant to the Atomic Energy Act of 1954 and the Energy Reorganization Act of 1974, as amended, and the Commission's Rules and Regulations thereunder, Consumers Power Company submits our response to NRC Compliance Bulletin 87-02 dated November 6,1987, entitled, "Fastener Testing to Determine Conformance with Applicable Material Specifications."
Consumers Power Company's response is dated January 12, 1988.
CONSUMERS POWER COMPANY
---lo~
F *W Buckman; S"en'"'h5't= \\l;lce President Energy Supply Sworn and subscribed to before me this 12th day of January,* 1988.
/~~le~./
Elaine E Buehr'er, Notary Public Jackson County My commission expires October 31, 1989 OC0188-0002-NL02-NL04
OC0188-0002-NL02-NL04 ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255
. NRC COMPlIANCE BULLETIN 87-02 FASTENER. TESTING DATA SHEETS January 12, 1988 48 Pages
Sample ID /1 PI/ L. - f
~1.t 11-r _ '-/II' S TCI 0 Fastener
Description:
/7
~'
Description of Sample Stock Location: P,O. 3..5-7tJ 7 a, # B Material Specification as Documented by Licensee Records: ;/ -193 1 r;~ B 7 Head Marking (Specification and Manufacturer):
(3 7 r-
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural) fv\\ /.SC, Vendor:
TEJ<~S BOt.-T co.
- 32. 3.3 f,AJ, £L.1Ct't"NT/"f S "/";
H ti~ Tei N; T F,x.A.5 7 7 oo t QA Requirements Imposed on Vendor:
c ea r1r:1 e.A re
~1= c o/V> P J,,/,etNce:..
- An explanat-ion of CPCo classification system is as follows:
_Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample. ID /1 J°A L - 2.
"3~ 11,,, S rl Fastener
Description:
71 A-Description of Sample Stock Location: P.O. 3.S-7CJ7 #/CJ Material Specification as Documented by Licensee Records: A -193 1 ~~(J7 Head Marking (Specification and Manufacturer): i3 7 T"
- Class/Procurement Level: 61<
General Plant Application (e.g., Pressure Boundary, Structural)
/Vt ISC..
Vendor:
T~7'A$ /3t/t...r co.
QA Requirements Imposed on Vendor:
C ;E!Z Tt.P' I e/fre' Or e Cl /YI r'L-1 /'l/lt'C £
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50~ APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II P/J L - 6
?~I/ ~
I It'
~
Fastener
Description:
'lb r~ '-/ Z SI Cl,..,,.
Description of Sample Stock Location: P. (), 3S 7t? 7 #" / /
Material Specification as Documented by Licensee Records: A- - IC/ 3.) ?te /3 7 Head Marking (Specification and Manufacturer): t:l 7 -,_
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
MISC..
Vendor:
T/£;<.AS
/3f? t. T co, QA Requirements Imposed on Vendor:
CEte.rtrJC"1TE oF C.o/Vl.f?t.l "NCC
- An explanation of CPCo classification system is as follows:*
Q; all applicable elements of a 10CFRSO, APP "B".QA program are utilized Non-Q; no elements of a 10CFRSO, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # PA l - 7 k, II I. II Fastener
Description:
I o/ X 7.Z Description of Sample Stock Location: P.CJ. 3SCj'/!;- ~
L{
Material Specification as Documented by Licensee Records: A -193.J tr/Z 13 7 Head Marking (Specification and Manufacturer):
l3 7 r J C Z S
- Class/Procurement Level: G<,
General Plant Application (e.g., Pressure Boundary, Structural)
/VI tSG Vendor:
TeXAS f3oL..T co, QA Requirements Imposed on Vendor:
c £,RT/F/c,,O MA/&;?tAL Tes;'T RtZPo/ZT NOT /fEro.~T5
- An explanation of CPCo classification syst~m is as follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II P ;t} L - Cf
~
I/
Fastener
Description:
!{ X 7 S TCIO Description of Sample Stock Location: P. {), 3 !:>- 9 IS-a # ~
Material Specification as Documented by Licensee Records: I/ -/9 3 1 C:.IC' 13 7 Head Marking (Specification and Manufacturer):
- Class/Procurement Level: tJ<.
13 7 T c z. ~
General Plant Application (e.g., Pressure Boundary, Structural)
/VtlSC.
Vendor:
TI~ XA S B tJ t. T c c:>.
QA Requirements Imposed on Vendor:
CE~/ M/IT£RIA(..
r~sr RIZ-Po/ZI Nor res rs
- An explanation of CPCo classification system* is as follows:
Q; all applicable elements of a 10CFRSO, APP "B".QA program are utilized Non-Q; no elements of a 10CFRSO, APP "B" QA program are required CQ; all app~icable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFRSO, APP "B" QA program may not be required of the supplier
Sample ID II f'Al - /0 l
(/
/_ //
Fastener
Description:
~ X 21{
S 7~.</-)
-P3 Description of Sample Stock Location: P,O, /C'O/- tJ8e~
Material Specification as Documented by Licensee Records: /{ * '-16-3,,. ~,e { 6' t:?
Head Marking (Specification and Manufacturer):
6'60 C
- Class/Procurement Level: G(
General Plant Application (e.g., Pressure Boundary, Structural)
/Vt 1$ c Vendor:
C~/?.0/NAL /N//t:IST/f.1/IL P/C.<7t0, 3873 U/,, OQ.t/£/Y'PO
[.,AS //t5GAS; H/:1/4p,,t1-B-7'118" QA Requirements Imposed on Vendor:
C £~(; t:!'P Co/V'l.Pi. IANC£ t'ISl.'/ll. /Esr /fe1°o/i!I
.*An explanation of CPCo. classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # PAL '-/ /
I/
I ft' k
y 10 ~ 5 '7-/' / 0 Fastener
Description:
0 r,
v r vi Description of Sample Stock Location:.? O *.!J0/2-tf/.:,-Z, ft.; ( s 7-i 7 3 7 IJ')
Material Specification as Documented by Licensee Records: ;4 -/C/ 3.; 6-~ B 7 Head Marking (Specification and Manufacturer): /-1" S-B 7 C
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
!°!Zt= SS tr/{/:"
/3oc.t/VO~Y Vendor:
QA Requirements Imposed on Vendor:
t::C:~T MATJ:~1~t... TEsr /?1£!'7Cl/ZT YT T£5 T /?E?c>/Cl-IY\\*T lp;s r Ji::..£..po);:T PT lt=$T~l!:?c:J,T
- An explanation* of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID ii f'A L -/ 2 Fastener
Description:
~ /)c If{
11 STtl.0 739& fl.I (37-4'6 Z'a'"o)
Description of Sample Stock Location: P.O. /00.!;J -
7 Material Specification as Documented by Licensee Records: /l-/q3.J G;e 13?
Head Marking (Specification and Manufacturer): /3 7 C.
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
/V\\ I 5 L Vendor:
QA Requirements Imposed on Vendor:
C:: /:I{ I CJ P co,/".{ 1:? t.. I AH c £..
J/T resr ~tE-ro~r
- An explanation of CPC6 classification system is as *follows:
Q; all applicable elements of a 10CFR50, APP 11B 11.QA program are utilized Non-Q; no elements of a 10CFR50, APP 11B 11 QA program are required CQ; all applicable elements of a 10CFR50, APP "B 11 QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP 11B 11 QA program may not be required of the supplier
Sample ID II f';'/ l - 13 l II A/
Fastener
Description:
7
,,,l/ I Description of Sample Stock Location: P,o, 2002-7~Z-I !#J.1 {3 ?-3 3 b--~-7)
Material Specification as Documented by Licensee Records: A -Id/~ ~le. Z. ff Head Marking (Specification and Manufacturer): A Z tf
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
M tSC.
Vendor:
QA Requirements Imposed on Vendor:
C £,.1!/. or CO/vtPLl/J,l./C£ VT /EST l?.E?O IZT
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B". QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID fl f 11 L - I'-/.
3~ ir A//Jr Fastener
Description:
/~
1 1""
Description of Sample Stock Location: f?()_, 2CJtJ2 -76'Z/ ~'{ {3/-33SS"7)
Material Specification as Documented by Licensee Records: /j-19~.) ~!'? Z/I Head Marking (Specification and Manufacturer): rf Z ff
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Bou_ndary, Structural)
/\\/1 l.5 c Vendor:
CAr<.DIN/IL l.NOtlSTRt/J L
/'.R0/7acrs QA Requirements Imposed on Vendor:
<:.IE.e T; e;F CO,A-1. P'Ll4N'C£ 11r resr ;zero1<-I
- An explanation of CPCo classification system is as follows::-,:.-.
Q; all applicable elements of a 10CFR50, APP "B" _QA program *are nrili zed*
Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50,. APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II P7/-l -/ !J-I/
Fastener
Description:
~ HUT Description of Sample Stock Location: R(), ZOO.Z. -7 8' '[;/ ;t.: t{ { 3 7-33.5 S 7)
Material Specification as Documented by Licensee Records: 11-/9'~ ~/( Z ff Head Marking (Specification and Manufacturer): If Z. H
- Class/Procurement Level:~
General Plant Application (e.g., Pressure Boundary, Structural)
Pte.ESSc.t~ £ l3o<<NO/e Y Vendor:
QA Requirements Imposed on Vendor:
C..,E.I{. T. ~ F co /Y1 1'7'-/,,,.,/'/ C /£.
c..,e~r. MAr,e,erAL r1:sr RP-?o~r vr resr /"?E?o,,er
- An explanation of CPCo cla.ssification system is as. follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II /lA L - / b Fastener
Description:
{
11 N t-1 T Description of Sample Stock Location: A(}, ZcJO/- 2 2 6Sff / (3?-33£32)
Material Specification as Documented by Licensee Records: /1-/'j Lf; C:,~ c/I Head Marking (Specification and Manufacturer): 2?..;f c-u
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
/'IU SC-Vendor:
QA Requirements Imposed on Vendor:
C ~~T OF coMr'L-1/1.NC/£.
VT -T/£5T r?e,Po!er
- An explanation of* CPCo classification system* is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFRSO, APP "B" QA program may not be required of the supplier
Sample ID II PAL -/8 I(
Fastener
Description:
?g
!Y'tl~
Description of Sample Stock Location: P.C.>,S-ol8-6tf.S-9 ""I (37-33S65)
Material Specification as Documented by Licensee Records: A-('(~ ~
ZI/
Head Marking (Specification and Manufacturer}: H Z H
- Class/Procurement Level: £Q.
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
/'At Sc.
A rt G-
- Nr;.1H ;
- =e,e1N~ co. 1Hc, L{( t(O t3
- ?/1/?AlM/J /fVG AIYA-HllEM 1 C.~L/,C-Cf?<?06 QA Requirements Imposed on Vendor:
C: E~T. tJF C0/\\.11 ?Lt/J,N'CtE VT Tes T ft.~r'q£r
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFRSO, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID fl /?// l-20
/_I/
Fastener
Description:
1/£( HU r Description of Sample Stock Location:
e f!OL 2002- ?fft../ 2 1F I (!7-t57CJ '12-)
Material Specification as Documented by Licensee Records:
~ -/9tf7 fr.R.. 8 Head Marking (Specification and Manufacturer): '4 b CG-C e f3
- Class/Procurement Level: (.(
General Plant Application (e.g~, Pressure Boundary, Structural)
Vendor:
Mt Sc c ARO LN,;1£,
lNOttsr;ZtA(..
r'1e0Pacrs QA Requirements Imposed on Vendor:
~ eAr. M~TER.t/lt-T£sr f?~?oter v T I/Zs T R. ff-1'o JC.T f'T TIZ-5 T
~ ero,er
- An explanation of CPCo classification system is as follows;*:
Q; all applicable elements of a 10CFR50, APP "B" *QA program are l?til+/-%ed*.-.
Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID n f Al - 2 2.
I
-~,, t.1ur*
Fastener
Description:
~ /T Description of Sample Stock Location: P.O. 2 00 2 - 17 't'l #I ( 28 -SJ 7'0-.7)
Material Specification as Documented by Licensee Records:.1- /'f t{1 ~~ b Head Marking (Specification and Manufacturer): 6 C P
.It b
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural) l°~t£s5c,t1<£
- t5oa,1y17 ;e_y Vendor:
QA Requirements Imposed on Vendor:
C t:.R T ot=
COM,PLt,,t/NC/£..
.VT T~ST /-?1£/'o/eT PT res r t? e.*f7() !<T
- An explanati~n of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B". QA program are utilize*d Non-Q; no elements of a 10CFR5.0, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
e 1~*
e Sample ID II f'I/ L. -2 'f
/_II II Fastener
Description:
~ X.. 3
/3 C) LI Des-cription of Sample Stock Location: P,t), 6/S?O.P:. b Material Specification as Documented by Licensee Records: It - 3 rJ ?, ~,.<? [3 Head Marking (Specification and Manufacturer): NON:.
- Class/Procurement Level: Ci<,
General Plant Application (e*.g., Pressure Boundary, Structural)
Vendor:
{°.Re >.S tt~e /3t:'CINP/Z y Hl+flR'/ w, T//Yt-01~
S.3f3Z.. w YNN RO tr"Al/l-M-lf~oo 1 M1uf l/1ot>3 QA Requirements Imposed on Vendor:
e!IZRT. C?P C()/Y'/Pt.1ANC IZ
- An explanation of C~C.c:> classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
I e
Sample ID II Pll l :_ 2 6-J_ 'I Fastener
Description:
~ IY Cl r e
Description of Sample Stock Location: R CJ, 6 /.570 ti: 7 Material Specification as Documented by Licensee Records:.t+-"30 7 1 &,e B Head Marking (Specification and Manufacturer): / y z H
- Class/Procurement Level:
~
General Plant Application (e.g., Pressure Boundary, Structural) f'Je.e -ss a I? e t3o~N.17 l{.y Vendor:
1+ If r< r'i v w~ 1 /I Y '-o /?..
QA Requirements Imposed on Vendor:
C£1zr. ()!='
C.o/VIP?l~NCE
- An explanation.of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utili2;ed
.except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # FA L -2 6 Fastener
Description:
Description of Sample Stock Location: ?.CJ, ZOO/- 42 2./,ct./
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): C 2. l/ I
- Class/Procurement Level: l\\
General Plant Application (e.g., Pressure Boundary, Structural)
MISC Vendor: r ex.'15 tJ o t.. I QA Requirements Imposed on Vendor:
CF-ter AAA-re~IA-L re-sr ~epo,er ti IS u /It.. /i!/<-"4,A/\\,
Fk!./1-CT~lfC:.
TOtl~/1141.£SS TES"r.
- An.explanation of.CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "Bn QA program are utilize*d Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # ?1/ l - J.3 I. (/
ft I(
Fastener
Description:
71( X 2
~
t30 l-T Description of Sample Stock Location: P.0, llt:,30~
Material Specification as Documented by Licensee Records: If -30 7 Head Marking (Specification and Manufacturer):
/'Id~£
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural) s rR.uc..ru..e~ '-
Vendor:
P IE-'1~ 13 o.re.1'-1 s c.r::.1::w rJ-fl o t-T c::: o.
!"C/'17 Ht1ea1EL'- Ave 01cT!?IJtT1M I
't~z2.'6 QA Requirements Imposed on Vendor:
<::. e~r: cJ F e-~/Yro~M.A/Vc.£.
- An explanation o.f CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II ? If. L - 3 'f Fastener
Description:
~
11 H ti r Description of Sample Stock Location:
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
/Y0!-1~
- Class/Procurement Level: ~
General Plant Application (e.g.; Pressure Boundary, Structural)
MISC.
Vendor:
STAHLEY /NPttST)?l/35 639' ;V.
!fou.J$5re~ ~P, C~al$tJ>/Y1 Mlctr Lff6017 QA Requirements Imposed on Vendor:
C~/'i.r:. or-Ce>NrOl'?M ANCE
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
I...,
Sample ID I! f'Al -3~-
Fastener
Description:
-fa 11 ;< 2 // Bo LI Description of Sample Stock Locat-ion: f?.(), 13 4'-19~
GU./O ({8'( I Material Specification as Documented by Licensee Records:,I/ -:Jo?
Head Marking (Specification and Manufacturer): /YO/'lf:
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
Ml SC.
Vendor:
13 rJ-L SU ?f'Jt y 6 fl' S/.J-COU)/r/ /f P '38$
6octrct 1-1-AveN} 1Yf1c1../
11roro QA Requirements Imposed on Vendor:
CeA.T; ot=
CONt=o,e/l,A.A)..ICE
- An explanation of CPCo classification.system is as follows:
Q; all applicable elements of a 10CFR50, APP* "B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
(
Sample ID II f/.J l-3 b
~
1\\..1.nT Fastener
Description:
0/8 1~w Description of Sample Stock Location: f. 0. 13 'IL/'/ &
Material Specification as Documented by Licensee Records: ~
~ S 0.3 Head Marking (Specification and Manufacturer): JYo,,Y,,e
- Class/Procurement Level: 6<,
General Plant Application (e.g., Pressure Boundary, Structural)
!-A ISC.
Vendor:
QA Requirements Imposed on Vendor:
c /ER r C'r CONPC'/CM /INC&
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA*program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II /2A L - 3 7 Fastener
Description:
~II x.. z II Bot r Description of Sample Stock Location: Ra l/076 te # '-I tf.WO S?C' 7 Material Specification as Documented by Licensee Records: A -3 2.5-Head Marking (Specification and Manufacturer): ~ 1<!.
-'3z,?-..
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
f.AlSC QA Requirements Imposed on Vendor:
C £/<T, C)F CCJNFO,e.M /JNCI£
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample !D II P/I L -3 8 Fastener
Description:
}2 q N l1 T p; -
Description of Sample Stock Loc?tion: f?O, I J 0 766i 5
Material Specification as Documented by Licensee Records: ~ -~t":J Head Marking (Specification and Manufacturer): f./O/'//Z
- Class/Procurement Level: Q General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
MIS c.
SC~EW rf-A]oJ.r co, QA Requirements Imposed on Vendor:
~ E~ I OF ec::>/Y FO;e'/Yl A/VC~
- An *explanation of CPCo classification system i.s as *follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
e e
Sample ID II :FA L - 3 9 l
I/
- j. II Fastener
Description:
~ J<.. / -g,
/3 OL T Description of Sample Stock Location: P. (), 13 2.S/ 6J I1 J t::-(()0 ~-70 7 Material Specification as Documented by Licensee Records: /I -32!)
Head Marking (Specification and Manufacturer):
- Class/Procurement Level:
~~ ),..1,,
"</ ~
General Plant Application (e.g., Pressure Boundary, Structural)
/l/{ ISC Vendor:
PE'Al<r5<J~N SCR.£t</ rJ-fJo'-T ~o, QA Requirements Imposed on Vendor:
e£tef. 01:::
CoNr-o~/INC/£..
'!tAn explanation of CPCo classification system is as follows:'":*< *:~:- :.
Q; all applicable elements of a 10CFR50, APP "B". QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II PA l - t./CJ
{(
Fastener
Description:
~ HUT Description of Sample Stock Location: AO~ /3 2.SI Q
. ~((.){) 70 7 Material Specification as Documented by Licensee Records: l'f:-.S-6-3 Head Marking (Specification and Manufacturer): /VOIY'I£:..
- Class/Procurement Level: ~
General Plant Application (e.g., Pressure Boundary, Structural)
MISC Vendor:
QA Requirements Imposed on Vendor:
C £ te. T.. a!=" co H FcJ/2/Vl ANC£...
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilize*d Non-Q; no elements of a 10CFRSO, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # f'IJ l - l{ /
Fastener
Description:
~// ;<. 2 i I/ 13 0 l-T Description of Sample Stock Location: P.tJ, F-7 7 / 6 Q 1F /
Material Specification as Documented by Licensee Head Marking (Specification and Manufacturer):
- Class/Procurement Level: 62 Records: /f -3 Z :;-
A 3ZS-LP General Plant Application (e.g., Pressure Boundary, Structural)
MISC.
Vendor:
c HI CA to
~oHr,,eAcro,es St.-( ?PL y
~l'IS-U), t>-te/IN.O A.YE.
C/./-ICA ~C'; I t-L-
{ O I I 2..
QA Requirements Imposed on Vendor:
(!. t=,."{ (,, 0 F=
~
0 N ro ~M ANC Ii::.
- An explanation of CPCo classificatio"n system -is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II P~L - l/Z.
Fastener
Description:
-% If Ntt r Description of Sample Stock Location: RO, F- ?716& ttz Material Specification as Documented by Licensee Records: t1/- -:JC 5,_
Head Marking (Specification and Manufacturer): /'IO/YC:
- Class/Procurement Level: Q.
General Plant Application (e.g., Pressure Boundary, Structural)
NI IS C Vendor:
C::.. /f I C/f6=t7 co NT /e.11-C. Tote..S S' L.I./°/? L Y QA Requirements Imposed on Vendor:
C! £t<T; CJF c.oNFO;C/\\A./JNC.E.
- An explanation of CPCo classificat~on system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # f'A L - 3 SL ttx /ti Fastener
Description:
~
6
!30L. T Description of Sample Stock Location: MISC STH'13-300.S-Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
- Class/Procurement Level: HON - ~
I kY
/\\.*
General Plant Application (e.g., Pressure Boundary, Structural)
M 15 C.
Vendor:
s r,eoNC-S/1 Les ;Ne
~ 60~ SANrcJ,eO ST; Ml/.5/r:tE6<JN t*FT5 j MI
't 9 '/ 'i J./
QA Requirements Imposed on Vendor:
Nol'/"e:.
.**.-*_.,,,;.....:.~-.
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II ? Al - L.(
Fastener
Description:
~I( Nu r Description of Sample Stock Location:,AA I 5C 5 Tl'\\
13-300~-
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
1'/t>-fl~
- Class/Procurement Level: NO N-t(_
General Plant Application (e.g., Pressure Boundary, Structural)
NllSC Vendor:
STl?ON't.
SALGS INC QA Requirements Imposed on Vendor:
- An explanation of CPCo classification system is.as follows*:*.
Q; all applicable elements of.a 10CFR50, APP "B" _QA program are ttt11tz:e0 Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II f // l - ~-
ll 7/8 11'){ 3,l r 130.1r Fastener
Description:
fX /'
Description of Sample Stock Location: MI SC ST/"(13-300.S-Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):.//'\\ }<. Y
- Class/Procurement Level: NO IV - G..
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
MISC QA Requirements Imposed on Vendor:
/'10.HIE
- An ~xplanation of CPCo classification system is as follows:.
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
~---------------------------
Sample ID II fl/L - 9 Fastener
Description:
11 NU r Description of Sample Stock Location: /Yt /SC ST/'(
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): /'{0/Y!tZ
- Class/Procurement Level: Nol'!- a General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
M/5c.
5 Ttz.o/\\/6! S/t L/;5
/NC QA Requirements Imposed on Vendor:
- An explanation o*f CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II f>A l - J 7 Fastener
Description:
{
11 150 Lr Description of Sample Stock Location: MISC Material Specification as Documented by Licensee Records:
Head Marking (Specification and M*anufacturer): /I\\.LJ
- Class/Procurement Level: N ~,A./ - a General Plant Application (e.g., Pressure Boundary, Structural)
Ml5C Vendor:
SALe.5 11'/C QA Requirements Imposed on Vendor:
No He
- An explanation of CPCo classification system is as follows:.
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilize"d Non"':'Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID ii J°,4 l - / 9
~~ i1 A/hr.
Fastener
Description:
~
t~ "f° Description of Sample Stock Location: /Y1 (SC s TK ~ fl Na r Material Specification as Documented by Licensee* Records:
Head Marking (Specification and Manufacturer): f/O}I~
- Class/Procurement Level: /'ICJ)I- ~
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
Mt SC ST/20)'/~ SALe5 INC QA Requirements Imposed on Vendor:
NtJNE.
- Art explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B". QA program are utilize*d Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II FA L -2 f g--/ 11 lr 3 /; // /3 0 ' T Fastener
Description:
78",,
Description of Sample Stock Location:
MISC.$Tl-'(
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
/'/\\ ~
- Class/Procurement Level: f./O~-C<.
General Plant Application (e.g., Pressure Boundary, Structural)
MISC Vendor:
S /~ON(;. SALES INC QA Requirements Imposed on Vendor:
/'/ONE.
- An explanation of CPCo classification system is as follows:,
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II PAL - Z 3
£ If Fastener
Description:
% H ti r Description of Sample Stock Location: /Vl I 5 C ST(~
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): NON/£
- Class/Procurement Level: /'ION -Gt 13 -300~-
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
- v\\f5C.
QA Requirements Imposed on Vendor:
NO Ne
- An explanation of CPCo classif.ica,tion *system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
1
- Description of Sample Stock Location: Ml SC 5 Tl'(
/3 eJ~-
Material Specification as Documented by Licensee Records:
/_ l E
/
\\
Head Marking (Specification and Manufacturer):
- Class/Procurement Level: NoN-a.
General Plant Application (e.g., Pressure Boundary, Structural)
Ml.5 C Vendor:
QA Requirements Imposed on Vendor:
NONE..
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID # {'1/ l - 2 8 3£ (( 1...I/'* T Fastener
Description:
/~
'~""
Description of Sample Stock Location: M (SC 5 Tl(
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): /VO~/E
- Class/Procurement Level:
HON-~
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
/Vll.S<-
s r;e.oNt;. SAL E.S I /...{C QA Requirements imposed on Vendor:
- V(}Ne
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_ QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID ii FA L - 2 9 I ):. I/
Fastener
Description:
~ )<.
I 11 s-~ Botr Description of Sample Stock Location: ST!'l NO 3 /- 80/t50 Material Specification as Documented by Licensee Records:
(., 1~
~'
Head Marking (Specification and Manufacturer):
- Class/Procurement Level: Holl-&
General Plant Application (e.g., Pressure Boundary, Structural) t:'X!'AN s 10H
.'!-cu Hr t3ol-T1NC-Vendor:
6/NtrNOWN QA Requirements Imposed on Vendor:
- ~n explanatio~ of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFRSO, APP "B" QA program may not be required of the supplier
Sample ID fl,PIJ L - 3 0 Fastener
Description:
If I/ H ti r Description of Sample Stock Location:
ST/'( No 3 / - 80 I Cf 'i Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): /I Z.
H N
- Class/Procurement Level: HoN-tR General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
/:)( P/f N 51tJN,8 tJLrlNC-QA Requirements Imposed on Vendor:
)
- An explana_tion of CPCo classification system -is. as follows:
Q; -all applicable elements of a 10CFR50, APP "B". QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II /?/IL. -3 /
I t'. I(
Fastener
Description:
Description of Sample Stock Location: S Tl'(" No 3 7-SOt/SZ Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
- Class/Procurement Level: IYO/V-62 c 131 F
.s General Plant Application (e.g., Pressure Boundary, Structural) c: R.o5s o llt:r?..
P1Pe Eo1-r1,,vc..
Vendor:
U/ESTllV?/-l-CJCIS F-L-.Ct:::Tf'<IC
<::.o,,ep f.O, 130X 700 SCJuT/lr!Et-tO; IYt I l/~o *3 7 QA Requirements Imposed on Vendor:
/'IONC.
- An explanation of CPCo classification system.is as follows:
- Q; all applicable elements of a 10CFR50, APP "B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA progralI!- are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID ii f'A /.. - 3 Z.
Fastener
Description:
1.f 'I /'IC( T Description of Sample Stock Location: ST/I NO Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): :3 /3 6
- Class/Procurement Level: NOH-~
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
S Tot° V'l'1Lf'e FL/+NO.C..
QA Requirements Imposed on Vendor:
/'IONt:
. *An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B".QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II fl/ l - t/ 3 I/
"'?/ I/
{,,.
Fastener
Description:
- ?y,)(. L( ~ /Jot-r Description of Sample Stock Location:
/vf. /SC ST/'('
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
}J~
- Class/Procurement Level: NoN-Q 1.5-.Joo_~-
General Plant Application (e.g., Pressure Boundary, Structural)
MISC Vendor:
s T!CoN6.
sALc:S INC QA Requirements Imposed on Vendor:
No Ne
- An explanation of CPCo classification system is.as follows:
Q; all applicable elements of a 10CFR50, APP i'B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFRSO, APP "B" QA program may not be required of the supplier
Sample ID II P /I. L - L( l-/
Fastener
Description:
% {I N t( r Description of Sample Stock Location: M /.)C srrr Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer):
No N IZ
- Class/Procurement Level: NOH-Q.
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
MISC.
S Tfe.o/\\/C-Sli L.IE.5" INC QA Requirements Imposed on Vendor:
HONE..
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B" QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are-utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier 1
Sample ID II PAL - t./..J-Fastener
Description:
'71t 11
)(. (II lJOLT Description of Sample Stock Location: M l.5C S Tl-f Material Specification as Documented by Licensee Records:
/J Head Marking (Specification and Manufacturer):
."\\
- Class/Procurement Level: NC.'1'-1£.... ~
General Plant Application (e.g., Pressure Boundary, Structural)
MISC Vendor:
s T!CoNG-SA LeS QA Requirements Imposed on Vendor:
NON.
- An explanation of CPCo classification system is as follows:*
Q; all applicable elements of a 10CFR50, APP "B" _QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID I! PA l - 'I b 7/16 i.l/*T Fastener
Description:
/Ii 1~c,c Description of Sample Stock Location: )Vl / 5C S Tt('
Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): N (J Ne
- Class/Procurement Level: NOH-Cl General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
MISC 5TRoN'6-Siil/ES 11'/C QA Requirements Imposed on Vendor:
- An explanation of CPCo classificatiori system is as follows:
Q; all applicable elements of a 10CFR50, *APP "B". QA program are utilized Non-Q; no elements of a 10CFRSO, APP "B" QA program are required CQ; all applicable elements of a 10CFRSO, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID H FA.L -4 7 Fastener
Description:
2 {
11 H {I/--
Description of Sample Stock Location: L-PIZ-/078' Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): NONIE
- Class/Procurement Level: HDN-a_
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
~CJO'- 1/\\/G row e1~
l'flf!?.O lt.lA/?e.
St°eCtAltlY
'f8-7b 3/ Tfl ST*
/-ON6-lSl,t/.IJJ C//-y1 1yy
//IOI QA Requirements Imposed on Vendor:
- An explanation of CPCo classification system is as follows:
Q; all applicable elements of a 10CFR50, APP "B"_QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
Sample ID II f'A L - lf B
- f.
/%'I Fastener
Description:
2 /;:( X. O 't f3 0 '- I Description of Sample Stock Location:
8 7-3 (8 S 7 Material Specification as Documented by Licensee Records:
Head Marking (Specification and Manufacturer): TJ'\\
- - L/,~-18
- Class/Procurement Level:
No N - ~
General Plant Application (e.g., Pressure Boundary, Structural)
Vendor:
CooL1N6:. rowet<
QA Requirements Imposed on Vendor:
- An explanation of CPCo classification system is as. follows:
Q; all applicable elements of a 10CFR50, APP "B". QA program are utilized Non-Q; no elements of a 10CFR50, APP "B" QA program are required CQ; all applicable elements of a 10CFR50, APP "B" QA program are utilized except:
a) 10CFR21 reportability is not invoked on supplier b) a 10CFR50, APP "B" QA program may not be required of the supplier
OC0188-0002-NL02-NL04 ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 NRC COMPLIANCE BULLETIN 87-02 MECHANICAL AND CHEMICAL TEST DATA January 12, 1988 6 Pages
Administrative Data
- Stud, Sample Nut or ID Number Bolt Size Vendor Marking PAL-1 s
3/4 Texas Bolt B7T PAL-6 s
7/8 Texas Bolt B7T PAL-7 B
1-1/4 Texas Bolt B7T, C28 PAL-9 s
1-1/8 Texas Bolt B7T, C26 PAL-10!
s 1/2 Cardinal Ind G60C PAL-11 s
1-7 /8 Cardinal Ind KS B7C PAL-12 s
3/4 Cardinal Ind B7C PAL-13 N
1/2 Cardinal Ind A211 PAL-14 N
3/4 Cardinal Ind A2H PAL-15 N
3/4 Cardinal Ind A2H PAL-16 N
1/2 Cardinal Ind 2H C-U l'AL-18 N
7/8 A&G Engineering
(-) 211 l'AL-20 N
l-1/4 Cardinal Ind A6 CG C BB PAL-22 N
I-1/8 Cardinal Ind 6CF A6 PAJ.r24 B**
1/2 Harry W Taylor PAJ.-25***
N 1/2 Harry W Taylor TY 2H PAL-26 N
1-7/8 Texas Bolt C241 7T l'AJ.-33 B
] /4 Dearborn Screw & Bolt PAJ.-34 N
1/4 Stanley Ind
- See A-370, Paragraph 15.1, Hardness Approximates Tensile.
- See Paragraph 5.4 of ASTM A-307.
- Specifications are from a 194 GR2H, based on results of sample tests.
Mll287-0246B-TPI5 Seecification Result Hardness UTS A-193, GRB7 125 Min HRC29.4 146.9 125 Min 156.4 A-193, GRB7 HRC33*. 7 A-193, GRB7 125 Min HRC34.8 157.5 A-193, B7 125 Min HRC32.0 149.3 A-193, B7 125 Min HRC32.2 11,8.2 A-453, GR660 1!18248-24.
130 Min 1118341-37 HRC40.61**
192.0 A-193, B7 125 Min llRC26. 2 127.3 A-193, B7 125 Min llRC27.5 129.4 A-194, 211 HRC24~38 llRC28.I 194, 211 HRC24-J8 HRC27. 7 A-194, 211 llRC24-38 llRC27.5 194, GR2H llRC24*38 llRC29.1 A-194, GR211 HRC24-38 HRC28.6 194, GR8 l!RB60-105 llRB85.9 194, GR6 HRC20-28 HRC26.6 A-307, GRB l!RB69-95 llRB82. 2".*
A-307, GRB HRC24-38 (By PO)
Probably 194, llRC29.4 211 Marking Not Specified HRC24-38 Probably 194, HRC26.8 CR7 A-307 HRB69-95 HIUl90.6 Not Spec i fled llRB89.5 Mechanical Test Studs Hach[neil Seecimen Reduction YS
~
Area %
105 Min 16 Min 50 Min 134. 7 20.5 62.2 105 Min 16 Min 50 Min 116.3 18.0 58.3 105 Min 16 Min 50 Min 148.0 16.1 55.4 105 Min 16 Min 50 Min 129.4 21.4 59.2 105 Min 16 Min 50 Min 135.7 19.3 59.8 85 Min 15 Min 18 Min 153.3 15.6 38 105 Min 16 Min 50 Min 112. 7 21.9 56.5 I05 Min 16 Min 50 Min I06.0 24.5 59.0 Data Failure Load 8,500-14,I90 9,970 1,900-3,180 2,850 1
Bolts Only Full Size Test UTS YS
Sample ID Number PAL-1 PAL-2 PAL-6 PAL-7 PAL-9 PAL-10 PAL-11 PAL-12 PAL-13 PAI.-14 PAL-15 PAL-16 PAL-18 PAL-20 PAL-22 PAL-24 PAL-25 PAL-26 PAl.-33 PAL-34 Speclfication Result A-193, GRB7 A-193, GRB7 A-193, GR87 A-193, 87 A-193, 87 A-45), GR660 A-193, 87 A-193, 87 A-194, 2H 194, 2H A-194, 211 194, GR2H A-194, GR211 194, GRB 194, GR6 A-307, GRB A-307, GRB (By PO)
Probably 194, 2H Marking Not Specified Probably 194, GR7 A-307 Not Specified Hll287-0246R-TP15 Carbon c
Manganese Mn
.37-.49
.65-1.1
.40
.89
.37-.49
.65-1.1
.40
.97
.37-.49
.65-1.1
.41
.80
.37-.49
.65-1.1
.39
.84
.37-.49
.65-1.l
.40
.85
.OB Max 2.O Max
.06 1.48
.37-.49
.65-1.1
.42
.89
.37-.49
.65-1.1
.41
- 79
.4 Hin
.41
.59
.4 Hin
.40
.57
.4 Hin
.41
.58
.4 Hin 0.47
.69
.4 Hin
.41
. 75
.oa Max 2.0 Max
.06 1.1
.15 Max 1,0 Max
.13
. 77
.25
.53
.4 Hin
.42
.81
.37-.49
.65-1,l
.44
.85
.14
.35
.07
.43 Phosphorus p
,04 Max
.008
.04 Max
.006
.04 Max
.ooa
,04 Max
,018
.04 Max
,007
,04 Max
.005
.04 Max
.016
.04 Max
.016
.04 Max
.027
.04 Max
,027
.04 Max
,025
,04 Max
,014
.04 Max
.019
.045 Max
.030
.04 Max
,029
.04 Max
<.oos
.017
.04 Max
.01
.04 Max
,025
.021 Sulfur
__ s __
.04 Max
.017
.04 Max
.016
.04 Max
.029
.04 Max
.017
.04 Max
.022
.03 Max
(.005
.04 Max
.014
,04 Max
.018
.05 Max
.018
.05 Max
.015
.05 Max
.016
,05 Max
.019
.05 Max
.016
.03 Max
.022
.03 Max
,012
.05 Max
.03
.05 Max
.022
.04 Max
.025
.05 Max
,033
.016 Chemical Test Data Silicon Si Molyb-denum Ho Chromium. Nickel
__ c_r__
.15-.35
.15-.25
.15-1.2
.20
.21
.82
.15-.35
.15-.25
.75-1.2
.22
.20
.94
.15-.35
.15-.25
.75-1.2
.28
.21
.87
.15-.35
.15-.25
.75-1.2
- 28
.18
.84
.15-.35
.25
.15-.25
.23
. 75-1.2
.*92
.02
.03
.15
.02
.09 1.0-1.5 13.5-16.0 24-27
.76
.15-.35
.26 1.02
.15-.25
.15 13.93
.75-1.2
.93
.15-.35
.15-.25
,75-1.2
.15
.15
.88
.16
.01
.12
.15
.01
'.12
.14
<:.Ol
.12
.17
<.Ol
.15
.22
.01
.04 1.0 Max 18-20
.54
.13 18.77 1.0 Max 11.5-13,5 24.75
.07
.06
.05
.05
.05
.01
.01 8-10,5 8.09
.28
.06 11.65
.43
<.01
.02
.15-.35
.27
,05
.02
.04
.05
.02
.12
,03
.15-.25
.75-1.2
.21
.90
.12
<.01
.05
.OJ
-<:.Ol
.01
.01 Copper Qi
.04
,06
.13
.OJ
.07
.15
.11
.11
.11
.11
.11
.01
.02
.17
.06
.02
.05
.16
.04
.01 Vana-dium v
.1-.5
.34
.005
.04
.005 Titanium T_i_
l.9-2,J5 2.08
<.Ol Sele-nium
~
<:.Ol Colum-bium
~
Tan-talum
_1!_
Tung-sten
_w_
Aluminum AI
.035
.038
.053
.034
.022
.35 Max
.25
.021
.006
.01
.01
.009
.018
.028
<.005
,036
.052
,005
.011 lA Boron B
=e
.001-
.01
.007
Administrative Data
- Stud, Sample Nut or ID Number
~
Size Vendor PAL-35 B
5/8 B&L Supply PAL-36 N
5/8 B&L Supply PAL-37*
B 1/2 Dearborn Screw and Bolt PAL-38 N
1/2 Dearborn Screw and Bolt PAL-39*
B 1/2 Dearborn Screw and Bolt PAL-40 N
1/2 Dearborn Screw and Bolt PAL-41*
B 3/4 Chicago Contractors Supply PAL-42***
N 3/4 Chicago Contractors Supply
- Chem test results satisfy Type One (1) specifications.
Marking A-325 A-325 UNY A-325 LF Specification Result A-307 A-563, GRB A-325**
A-563 A-325**
A-563 A-325**
A-325
- See Paragraph 6.4 of A-325 (tensile supersedes hardness for acceptance).
- A-325 Type One (1) bolt calls for A-563 Grade C nut.
Those are limits specified.
MI12B7-0246B-TP15 Hardness HRB69-95 llRB93.4 B69-C32 llRB87.2 HRC24-35 llRC32.6 B69-C32 llRB95.9 HRC24-35**
HRC30.6 B69-C32 llRR8B.O
- llRC24-35 llRC29. 2 HRB78-llRC38 HRB82.B Studs Mechanical Test Data Machined Specimen
\\
YS
~
Reduction Area %
Bolts Only Full Size Test Failure Load UTS 13,550-22,600 19,150 17,050 Hin 21,400 17,050 Hin 20,050 40,100 Min 49,400 2
2A
~
Chemi~al Test Data f
Molyb-Vana-Sele-Col um-Tan-Tung-Sample SEecificat Ion Carbon Manganese Phosphorus Sulfur Silicon denum Chrom.ium N.ickel Copper di um Titanium nium bium talum sten Aluminum Boron ID Number Result c
Mn p
s Si_
Mo C_r __
Ni Cu v
Tl Se
~
w Al B
PAL-35 A-307
.04 Hax
.05 Max
.05
.38
.016
.013
.05
<.Ol
.03
.02
.05
.009 PAL-36 A-563, GRB
.58 Max
.13 Max
.06
.32
.008
.OU
<.Ol
<.Ol
<.Ol
<.. 01
.01
<.005
<.005
<.01 PAL-37 A-325
.36
.74
.011
.019
.20
<.01
.04
.02.
.05
.01 l'AL-38 A-563
.58 Max
.13 Max
.05
.29
.012
.012
.08
<.Ol
<.01
<.Ol
.01
<.005
<.005
<.Ol PAL-39 A-325
.33
.76
.018
.021
.24
.OJ
.15
.07
.14
.025
.013 PAL-40 A-563
. 58 'Max
.13 Max
.18
.31
.019
.024
<.Ol
<.Ol
.04
.01.
.01
<.005
<.005
<.01 PAL-41 A-325
.47
.99
.017
.025
.22
.07
.22
<.01
.01
<.005 PAL-42*
A-325
.58 Max
.13 Max
.09
.45
.005
.009
<.01
<.01
.02
<.01
.01
.007
- A-325 Type One (1) bolt calls for A-563 Grade C nut.
Those are limits specified.
Mll287-0246B-TP15
Administrative Data
- Stud, Sample Nut or ID Number Bolt Size Vendor PAL-3 B
5/8 Strong Sales Inc PAL-4 N
5/8 Strong Sales Inc PAL-51 B
7 /8 Strong Sales Inc PAL-8 N
7/8 Strong Sa*les Inc PAL-17 B
1/4 Strong Sales Inc PAl.-19 N
l/4 Strong Sales Inc PAL-21 B
5/8 Strong Sales Inc PAL-23 N
5/8 Strong Sales Inc PAL-27 B
3/4 Strong Sales Inc PAL-28 N
3/4 Strong Sales Inc PAL-29 B
1-1/8 Unknown PAL-JO N
1-1/8 Unknown PAl.-31**
B l-1/8 Westinghouse PAL-32**
N 1-1/8 Westinghouse PAL-43 !
B 3/4 Strong Sal es Inc PAl.-44 N
3/4 Strong Sales Inc PAL-45 B
7/16 Strong Sales Inc PAL-46 N
7 /16 Strong Sales Inc PAL-47 N
2-1/4 Hardware Specialty PAL-48 ll 2-1/4 Hardware Specialty
- This is AS'll1 A-563 Grade A spec acceptance criteria.
- Based on chemistry result Mll287-02468-TP15 3 -
-J (
Mechanical Test Data Studs Bolts Onl;t Racfi!nea Seecimen Fun Size Test Seecification
\\
Reduction Marking R:esult Hardness
~ YS
~
Area %
Failure Load UTS
~
KY A-449, SAE GR5 llRC25-34 By Markings HRC29.2 GR2 HRB84 Min Probably A-194
.llRB91. 2 KY A-449, SAE GR5 H)tC25-34 By Markings llRC24.6!
SAE GR2 HRB68-llRC32 llRB92.0 A-449, SAE GR5 llRC25-34 lly Markings llRC28.l SAE GR2 B6B-C32*
HRB93.6 s
A-449, SAE GR5 HRC25-34 By Markings llRC28.0 SAE GR2 B68-C32 HRB93.8 l.E A-449, SAE GR5 HRC25-34 By Markings llRC30. 7 SAE GR2 B68-C32 By Ha rkings HRR90.8 A-449, SAE GR5 llRC19-30 By Markings HRC25.6 112 llN HZ and HN By Markings HRC26.8 CB 7F A-193, B7 s
By Markings llRCJO. 7 388 194 GRJ HRC2lt-38 llRCJl. 7 e
KS A-449, SAE GR5 llRC25-34 By Markings llRC23.91 SAE GR2 B68-C32 By Markings llRB93. 5 N
A-449, SAE GR5 llRG25-34 llRC31.l Not Specified llRB91. 3 Not Specified llRB73.8 TK J4518 J4518 By Markings llR875. 3
Sample JD Number PAL-3 PAL-4 PAL-5 PAL-8 PAL-17 PAL-19 PAL-71 PAI.-23 PAL-27 PAL-28 PAL-29 PAL-30 PAL-31 PAl.-32 PAL-43 PAL-44 PAl.-45 l'AL-46 PAL-4 7 l'AL-48 Specification Rf'sult Carbon c
.25-.58
.57 Hin By Ha,rkings
. 31
- 71 SAE GR2
. 55 Max Probable Spec
.06
.46 A-449, SAE GR5
.25-.58
.57 Hin By Markings
.29
.78 SAE GR2
. 55 Max
.16
. 73 A-449, SAE GR5
.25-.58
.57 Hin By Markings
. 30
.66 SAE GR2*
.55 Max
.11
.33 A-449, SAE GR5
.25-.5B
.57 Hin By Markings
.29
.75 SAE GR2
.55 Max
.06
.39 A-449, SAE GR5
.25-.58
.57 Hin By Markings
.38
.81 SAE GR2
.55 Max By Markings
.05
.48 A-449, SAE GR5
.25-.58
.57 Hin By Markings
.43
.81 llZ and HN By Markings A-193, 87 By Markings 194 GR3
.49
. 77
.37-.49
.65-1.l
.47
. 87
.10 Hin 1.0 Max
.19
.47 A-449, SAE GR5
.25-.58
.57 Min By Markings
.32
.74 SAE GR2
.55 Max By Markings
.05
.46 A-449, SAE GR5
.25-.58
.57 Min
.34
.69 Not Specl fied
.OB
.29 Not Specified
.15
.66 J4518 By Markings
.27
. 71 Phosphorus p
.048 Max
.014
.12 Max
.02
.048 Max
.021
.12 Max
.015
.048 Max
.on
.12 Max
.019
.048 Max
.012
.12 Max
.019
.048 Max
.016
.12 Max
.016
.048 Max
.014
.OU
.04 Max
.01
.04 Max
.016
.048 Max
.009
.12 Max
.021
.04B Max
.OlB
.006
.012
.006
- This is ASTH A-563, Grade A spec acceptance criteria.
'"*Alloy lD AlSI 501 1Tl287-0246B-TP15
-~;.
.-~.-
Oiemical Test Data Sulfur s
Silicon Si Molyb-denum Mo Oiromiuin ' Nickel Cr Ni
.058 Max
.015
. 24
.15 Max
.009
.03
.05B Max
.016
. 24
.15 Max
.014
. 25
.058 Max
.021
.21
.15 Max
.016
.05B Max
.02
.018
. 22
.15 Max
.009
.02
.05B Max
.009
. 23
.15 Max
.007
.03
.05B Max
.024
.27
.01
.11
<.01
.02
<.Ol
.11
<.Ol
.01
.02
.OB
<.01
.02
.01
.15
<.01
.01
.15
.25
<.01
.02
.01
.13
.035
.23
.02
.37
.04 Max
.009
.03 Max
.01
.058 Max
.15-.35
.15-.25
.75-1.2
.2B
.19 l.07 1.0 Max
.4-.65
.53
. 54 4-6
- 5.01
.008
- 23
.01
.09
.15 Max
.01
.058 Max
.02
.018
.20
.005
<.01
.01
.20
.018
.12
<.01
.02
.01
.08
-<::.01
.01
.01
.12
<.01
.02
.06
.01
.02
.01
.05
.01
.05
.01
.03
.01
.01
.08
.01
.ll
- 05
.01
.04
.01 '
.06
<.01 Copper
~
.17
.02
.03
.03
.u
.02
.15
.01
.02
.02
.18
.13
.01
.05
.18
.01
.13
.01
.12
<.01 Vana-dium v
.13 Titanium Ti Sele-nium Se Colum-bium Cb
.014 Tan-talum Ta
.028
.029
.027
.11
.023
.029 Tung-sten w
Aluminum Al
.028
.035
<.005
.OU
.03
.017
.022
.013
.017
.039
<.005
.036
.045
.021
.024
.016
.019
.006
.013
<.005 3A Boron
- e
?
}
- ----*