Text
......_
.. *~
Idaho National,Eng/mJerlng Labomtor(
r*.
~I.,. i' May 1, 1987 Mr. M. Carrington, Project Manager Offi~e of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 TRANSMITTAL OF FINAL REPORT, "CONFORMANCE TO GENERIC LETTER 83-28, ITEM 2.2.2--VENDOR* lNTERFACE PROGRAMS FOR ALL OTHER SAFETY-RELATED COMPONENTS: PALISADES," EGG-NTA-7622, APRIL 1987 (FIN 06001) - EWR-110-87.
Ref:
NRC Form 189, "Evaluation of Conformance to Generic Letter 83-28 For ORs (Project 2)" ( 06001)
Dear Mr.
Car~ington:
Transmitted herewith is the above subject report.
The report documents INEL 1s evaluation of the licensee actions in response to NRC Generic Letter 83-28, Item 2.2.2--Vendor Interface Programs for All Other Safety-Related Components.
Based on the licensee submittal, we conclude that the plant does not conform to the generic letter on this item.
The licensee should establish interfaces with the vendors of major safety-r~lated equipment.
ACU:gp
Enclosure:
As Stated cc:
G. L. Jones, DOE-ID D. Lasher, SICB (2)
- Very truly yours, c:z3; OJ;;;-
E. W. Roberts, Manager NRC Headquarters Support