ML18052A258

From kanterella
Jump to navigation Jump to search
Forwards 1985 Steam Generator Inservice Insp Rept of Eddy Current Testing,Data Evaluation & Tube Repair. Insp Conducted on 851201-30.No Further Degradation of Steam Generator a or B Tubing Occurred
ML18052A258
Person / Time
Site: Palisades 
Issue date: 01/27/1986
From: Kuemin J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18052A259 List:
References
NUDOCS 8602030153
Download: ML18052A258 (1)


Text

consumers Power company General Offices: 1945 West Parnell Ro11d, Jackson, Ml 49201 * (517) 788-0550 January 27, 1986

Director, Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR~20 - PALISADES PLANT -

~1985 STEAM GENERATOR INSERVICE INSPECTION REPORT

\\ \\

/

In accordance with P~lisades Technical Specificatiq'.n 4.14.6, the enclosed Steam Generator Inseivice Inspection Report is sub~itted.

The inspection occurred from December 1 to December.' 30, 1985 when the final tube plugging occurred.

A total of eight (8) tubes,;.were plugged following the inspection; all were located in "B" Steam Generator:"* (see Attachment 5 for details).

The number of tubes plugged does not vJoi~te the assumptions or change the safety analysis.,I It is Consumers Power Company's belief that the str1'cf *adherence to secondary water.purity limits and maintaining the secondary s'a:de of the steam generators in wet lay-up, as much as possible, during non-oper~ting conditions has limited tube corrosion.

The results of 1985 inspec~ion show, essentially, no further degradation of the "A" or "B" steam generat~r tul;>ing occurred during the last operating cycle.

o~?f.~

~ames L Kuemin Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades

  • ea02030153 860127 w*.

'1*

PDR ADOCK 05000255 G

PDR !

I

-(

OC0186-0012-NL02