consumers Power Company General Offices: 1945 West Parnell Raad, Jackson, Ml 49201 *.{517) 788-0550 FEBRUARY 13, 1985 James G Keppler, Administrator Region.III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR ~+J PALISADES PLANT -

REACTOR INTERNALS NOISE MONITORING TESTS Palisades Plant Tech_nical Specification 4.13. D. 3 requires the results of the Reactor Internals Noise Monitoring Tests to be submitted to the NRC Region III office on an annual basis.

The results of the test demonstrates the reactor core barrel is tightly clamped with no other anomalous vibrations occurring during the testing period.

The attached test fulfills the requirement of the subject Technical Specification.

Brian D Johnson Staff Licensing Engineer CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector - Palisades

(

~D5R02260r36 850213 p

ADOCK 050002551 PDR

' I RX-INTERNALS-85-0lA FEBi9 \\985