ML18051B001

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-20,revising Tech Spec Section 6.17 to Require Implementation of Program Ensuring Capability to Obtain & Analyze Reactor Coolant,Radioactive Iodines & Particulates in Plant Gaseous Effluents
ML18051B001
Person / Time
Site: Palisades 
Issue date: 07/09/1984
From: Dewitt R, Durfey S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML18051B000 List:
References
RTR-NUREG-0737, RTR-NUREG-737 GL-83-37, NUDOCS 8407130149
Download: ML18051B001 (2)


Text

Consumers Power Compahy Docket 50-255 - License DPR Palisades Plant Request For Change to Technical Specifications For the reasons hereinafter set forth, it is requested that the Technical Specifications contained in the Provisional Operating License DPR-20, Docket 50-255, issued to Consumers Power Company on October 16, 1972, for the Palisades Plant be changed as described in Section I below.

I.

Changes A. Add the following section to Section 6:

"6.17 Post Accident Sampling The licensee shall implement a program which will ensure the capability to obtain and analyze reactor coolant, radioactive iodines and particulates in plant gaseous effluents, and containment atmosphere samples under accident conditions.

This program shall include the following:

1. Training of personnel
2. Procedures for sampling and analysis
3. Provisions for maintenance of sampling and analytical equipment" NOTE:

Revised Technical Specification Pages are attached.

Proposed changes are shown by a vertical line in the right-hand margin.

II.

Discussion The above change to the Palisades Technical Specifications is required per NUREG-0737, "Clarification of TMI Action Plan Requirements".

The change is in accordance with the guidance provided in Generic Letter No 83-37 on NUREG-0737 Technical Specifications.

MI0684-0015B-NL02

. 840.7i30149 8'4.0709.. :.,> *

  • PDR ADOCK -05000255 :

P PDR

III. CONCLUSION The Palisades Plant Review Committee has reviewed this Technical Specification Change Request and has determined that this change does not involve an unreviewed safety question and therefore involves no significant hazards consideration.

This change has also been reviewed under the cognizance of the Nuclear Safety Board.

A copy of this Technical Specification Change Request has been sent to the State of Michigan official designated to receive such Amendments to the Operating License.

CONSUMSERS POWER COMPANY BY R B DeWitt, Vice President Nuclear Operations Sworn and subscribed to before me this 9th day of July 1984.

Sherry L fey, Notary Jackson County, My commission expires November 5, 1986.

SHERRY LYNN DURFEY Notary Public, Jackson County, Mleh.

My Commission Expires Nov. 5, 1986 MI0684-0015B-NL02