ML18051A866
| ML18051A866 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 04/24/1984 |
| From: | Paulson W Office of Nuclear Reactor Regulation |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| LSO5-84-04-053, LSO5-84-4-53, NUDOCS 8404270079 | |
| Download: ML18051A866 (5) | |
Text
--_---- - ---:_-~---- ---~:--
April 24, 1984 Docket No. 50-255 LS05-84-04-053 LICENSEE:
CONSUMERS POHER COMPANY FACILITY:
Palisades Plant
SUBJECT:
a,.., _-If u
SUMMARY
OF APRIL 9 AND 10, 1984 MEETINGS
-~ ~
On April 9 and 10, 1984, the staff met with representatives of Consumers Power Company in Bethesda, Maryland.
The purpose of the meetings was to discusi the licensee's technical evaluation of the inspection of the Palisades steam generators.
The attendees at the meetings are listed on Enclosures 1 and 2.
On April 9, 1984, the licensee discussed the qualification of the eddy current technique (ECT) and the results of the eddy current inspection of the steam generator tubes.
Copies of the handouts are shown in Enclosure 3.
The licensee concluded that (1) the error of the ECT is +/-6%, (2) the thresh-hold of intergranular attack (IGA) quantification is about 303; the limit of_ detectability i.e. about 20%, (3) the volumetric IGA was initiated prior to 1978 and has had essentially a zero growth rate since 1978, and (4) the 4C4F probe technique detected a significant number of previously unidentified cracks in the 90° bends.
On April 10, 1984 the licensee discussed the technical evaluation of the steam generator tube inspection and plans for future operation.
The agenda and handouts are shown in Enclosure 4.
Based on the results of the steam generator tube evaluation, the licensee plans to plug all tubes with cracks and IGA defects of 51% through wall or greater maximum average depth as measured by the 4C4F probe.
A formal submittal of the material presented regarding the steam generator inspection and proposed plugging criteria
\\'Ji 11 be made for NRC review and approva 1.
The 1 i censee does not anticipate that any techni ca 1 speci fi cation changes wil 1 be rcqui red based on the proposed repair.
Consumers Poil-Jer Company plans to withdraw the technical specification change request of March 16, 1984 for operation with 503 plugged tubes.
The licensee proposed that the next ET inspection be performed during the 1985 refueling outage.
OFFICE. * ****************** ********************* **********************..................... *********************.......................... ~..............
SURNAME. * ****************** ********************* *********************..................... ********************* ********************* ******* : ************
DATE.
NRC FORM 318 110/801 NRCM 0240 OFFICIAL RECORD-COPY
-f:t: U.S. GPO 1983-400-247
~-... ::r-I
- ---- April 24, 1984 The licensee's current plans are to begin plugging tubes on April 20, 1984 with heatup scheduled for May 17, 1984.
Enclosures:
As stated cc 1:1/enclosure:
See next page DISTRIBUTION Docket File NRC PDR Local PDR NSIC ORB #5 Reading DCrutchfield LA WPaulson OELD ELJordan JNGrace ACR5 (10)
NRC Participants Original signed by Walter A. Paulson, Project Manager Operating Reactors Branch #5 Division of Licensing
'* --,-, '. :*. '\\*'
NRCFORM31sno1solNRCM0240 OFF~CIAL RECORD COPY
. f:f u.s.GPO 1983-400*247 1
., - ::.--*--;_.. _,:.:;; ~~
- .;:-**~*;.;._ ** -
--...:;,.,.._,Y -**:
- '*-*--:_*~-*** ~...........,~ ~* ~----..,,
- ~--. ---: --~..... --.. -::-** _:;:;-~.*-; *"-.:::-=-*-:_*-=-:-:*: ' -:,:...... ~*-~::;_ )*. *~.,.- ~"-*~-.;;_*,=.*>?:,,;-:~-.11~:::.... -::-~:;:~c:..-;;*-i$,;.*?--::~-i-.>O.-";;F....J3;j;'i:0:-.*,--.";~"r-,;..t..;,">,.;$-~;;r:-~.*-~* _:*.;'";'*;;~:;*.'r~~;~';:-,'.;:;::,:~*t:rj:*r;:,;."';-.*~_:.::*~L~
cc M. I. Miller, Esquire Isham, Lincoln & Beale Suite 4200 One First National Plaza Chicago, Illinois 60670 Mr. Paul A. Perry, Secretary Consumers Po0er Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd l. Bacon, Esquire Consumers Power Company
. 212 West Michigan Avenue Jackson, Michigan 49201 3 -
James G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137.
Township Supervisor Covert Township Route 1, Box 10 Van Buren County, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Palisades Plant ATTN:
Mr. Robert Montross Plant Manager Covert, Michigan 49n43 U.S. Er.vironmental Protection Agency Federal Activities Branch Region V Office ATTN:
Regional Radiation Representative 230 South Dearborn Street Chicago, Illinois 60~04 Resident Inspector c/o U.S. NR.C P.a 1 i sades Pl ant Route 2, P. 0. Bo~ 155 Covert, Michigan 49043 F
Apri 1 24, 1984
/
/
Lee E. Jager, P.E., Chief Environmental and Occupational
'i Health Services Administration Michigan Department of Public Health 3500 N. Logan Street Post Office Box 30035 Lansing, Michigan 48909 Mr. David J. VandeWalle Nuclear Licensing Administrator Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
rncLOSURE 1
~
LIST OF ATTENDEES Meeting of April 9, 1984 Palisades Plant NAME AFFILIATION W.
- Pauls on NRC C.Y. Cheng NRC H.F. Conrad l~RC D.J. VandeVla 11 e CPC
- v. R. Looper tlDE Technology W.J. Key NRC, Region I II S.R. Hellman CPC G.E. Seve ranee CPC J.R. Hinkle CPC T.F. Timmons l*/estinghouse J. Jandovitz CPC
J Meeting of April 10, 1984 Palisades Plant NAME W. Paulson H.F. Conrad W. J. Key B. D. Li av4 B. Mann L Lois
- p. \\fo C. McCracken J. R. Raj an G. Slade J. Schepers W.J. Bevous L.J. Laskmvski L. F. Ermo l d T.F. Timmons E. Hill R. Looper S
- R ~ We l l man G. E. Severance J. S. J andovitz
- G. Coll F. 14. Buckman C.Y. Cheng R.F. Keating
- J. L. Houtman D.J. Vande\\4alle r
- LIST OF ATTENDEES AFFILIATION NRC NRC NRC, Region III NRC NRC rmc NRC NRC NRC CPC CPC CPC Northeast Utilities*
14esti nghouse Westinghouse Bechtel NOE Technology CPC CPC CPC Newman & Holtzinger, PC.
Delian Corporation NRC
\\iiesti nghouse 14esti nghouse CPC ENCLOSURE 2