consumers Power company General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 September 30, 1982 Dennis M Crutchfield, Chief Operating Reactor Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR

AFW PUMP DIESEL LOADING NRC staff review of Consumers Power Company -submittal dated August 11, 1982 and entitled "Auxiliary Feedwater System Modification Additional Information" identified a question regarding confirmation that the motor driven Auxiliary Feedwater (AFW) Pumps (P-8A and P-8C) are loaded on the emergency diesel generators upon loss of off-site power.

This letter provides the confirmation that the Auxiliary Feedwater System Modification provides for the AFW pumps P-8A and P-8C to be loaded on the emergency diesel generators by the design basis accident (DBA) sequencer and the normal shutdown sequencer upon a loss of offsite power.

Brian D Johnson Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades 8210050265 820930 PDR ADOCK 05000255 p

PDR