ML18047A532

From kanterella
Jump to navigation Jump to search
Submits Revised Schedule Dates for Selected Action Items Resulting from SEP
ML18047A532
Person / Time
Site: Palisades 
Issue date: 08/17/1982
From: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
TASK-03-01, TASK-03-05.A, TASK-03-06, TASK-03-07.B, TASK-08-04, TASK-09-03, TASK-09-05, TASK-3-1, TASK-3-5.A, TASK-3-6, TASK-3-7.B, TASK-8-4, TASK-9-3, TASK-9-5, TASK-RR NUDOCS 8208230334
Download: ML18047A532 (2)


Text

~I consumers Power company David J VandeWalle Nuclear Licensing Administrator General Offices: 1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-1636 August 11, 1982 Dennis M Crutchfield, Chief Operating Reactor Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SYSTEMATIC EVALUATION PROGRAM In a letter dated March 31, 1982, Consumers Power Company provided a schedule for completing various action items which resulted from the SEP for Palisades.

The purpose of this letter is to confirm revised dates for selected action items as they were discussed recently by telephone with the staff.

The affected topics, cur~ent status and revised completion dates are as follows:

TOPIC III-1 III-5.A III-6 III-6 III-7.B 8208230334 820817 PDR ADOCK 05000255 P

PDR CURRENT STATUS EXPECTED COMPLETION DATE

  • Completed by submittal dated 8/16/81 Report submitted 8/16/81 reducing number of unacceptable break locations to thirteen.

Fracture mechanics work in progress for remaining locations.

Eccentric pipe loads - work in progress Electrical cabinet integrity and mounting adequacy of internal components - work in progress Approximately half of open items resolved and work is continuing on remainder.

Interim report will be submitted to close as many items as possible and define remaining work 11/30/82 9/30/82 12/20/82 8/31/82

DMCrutchfield, Chief Palisades Plant Systematic Evaluation Program August 17, 1982 TOPIC

. VIII-4 IX-3 IX-5 CURRENT STATUS Work in progress.

Submission of current results will be approximately 30 days later than estimate in CPCo letter of 11/16/81.

Report being prepared Testing delayed due to plant outage.

Additional 30 days will likely be required.

Nuclear Licensing Administrator CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades 2

EXPECTED COMPLETION DATE 9/30/82 8/31/82 10/29/82