ML18047A482

From kanterella
Jump to navigation Jump to search
Forwards Application for Amend to License DPR-20,requiring Check Valve Closure Following Use of Low Pressure Safety Injection Sys for Shutdown Cooling
ML18047A482
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/29/1982
From: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18047A483 List:
References
TASK-05-11.A, TASK-5-11.A, TASK-RR NUDOCS 8208020299
Download: ML18047A482 (1)


Text

...... _.

consumers Power company General _Offices: 1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-1636 July 29, 1982 Dennis M Crutchfield, Chief Operating Reactor Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR David J VandaWalle Nuclear Licensing Administrator PALISADES PLANT - PROPOSED TECHNICAL SPECIFICATION CHANGE REQUEST -

SYSTEMATIC EVALUATION PROGRAM TOPIC V-11.A Attached are three (3) originals and thirty seven (37) conformed copies of a Request for Change to the Palisades Technical Specifications.

The requested changes will update the Palisades Technical Specification in order to incorporate a new provision proposed in Conslliners Power Company letter dated March 31, 1982 and approved in principle in the Integrated Plant Safety Assessment, Systematic Evaluation Program, Palisades Plant (NUREG-0820).

Since the NRC has already reviewed this item under the SEP, this change is considered to be pro forma or administrative in nature.

Therefore a check in the amount of $1,200.00 is attached pursuant to 10 CFR 170.22 (Class II).

Nuclear Licnesing Administrator CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachment

/fo"!S'*

"'/,}.Gr-/r:

/I 1-a.00.00

( 8208020299 8207.29 r PDR ADOCK 05000255 P

PDR

. I