Forwards Comments by NRC Consultants Re Reviews of Draft NUREG-0820,integrated Plant Safety Assessment
Date released: 10/31/2018 Download: ML18047A285


Comments on SEP Integrated Plant Safety Assessment,Per Request.Sep Program Appears Well Organized
ML18047A330
Person / Time
Site: Palisades 
Issue date: 04/28/1982
From: Zudans Z
FRANKLIN INSTITUTE
To: RUSSELL W
NRC
References
RTR-NUREG-0820, RTR-NUREG-820
Download: ML18047A330 (7)
Submits Draft Review of Integrated Plant Safety Assessment of Sep.Review of Operating Experiences Needs to Be Updated & Augmented
ML18047A329
Person / Time
Site: Palisades 
Issue date: 04/23/1982
From: Isbin H
ISBIN, H.
To: RUSSELL W
NRC
References
RTR-NUREG-0820, RTR-NUREG-820
Download: ML18047A329 (8)
Critique of Integrated Plant Safety Assessment,Sep.
ML18047A328
Person / Time
Site: Palisades 
Issue date: 04/27/1982
From: Bush S
AFFILIATION NOT ASSIGNED
To:
References
Download: ML18047A328 (6)
Submits Technical Evaluation Rept on Facility Integrated Plant Safety Assessment Per Draft NUREG-0820.Rept Fulfills Intent of SEP
ML18047A327
Person / Time
Site: Palisades 
Issue date: 04/27/1982
From: Hendrie J
BROOKHAVEN NATIONAL LABORATORY
To: RUSSELL W T
Office of Nuclear Reactor Regulation
References
CON-FIN-A-3367, RTR-NUREG-0820, RTR-NUREG-820
Download: ML18047A327 (8)
Submits Review of Draft NUREG-0820, Integrated Plant Safety Assessment:Sep,Palisades Plant. Addl Matl May Be Provided at Later Date
ML18047A284
Person / Time
Site: Palisades 
Issue date: 04/15/1982
From: Budnitz R
FUTURE RESOURCES ASSOCIATES, INC.
To: RUSSELL W T
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0820, RTR-NUREG-820
Download: ML18047A284 (6)