ML18046B268

From kanterella
Jump to navigation Jump to search
Discusses SEP Topic III-5.B,pipe Break Outside Containment, Per NRC 811223 Evaluation.Jet Expansion Model Used by Util Agrees W/Nrc Criteria,Based on Analysis Contained in BN-TOP-2,Revision 1
ML18046B268
Person / Time
Site: Palisades 
Issue date: 02/09/1982
From: Vincent R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
TASK-03-05.B, TASK-3-5.B, TASK-RR NUDOCS 8202120078
Download: ML18046B268 (1)


Text

.. *~*

consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Ml 49201 * (517) 788-0550 February 9, 1982 Dennis M Crutchfield, Chief Operation Reactor Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LIGENSE DPR-20 PALISADES PLANT - SEP TOPIC III-5.B, PIPE BREAK OUTSIDE CONTAINMENT By letter dated December 23, 1981, the NRC issued an evaluation of SEP Topic III-5.B for the Palisades Plant.

Paragraph V.B.3 of the evaluation stated that the jet expansion model for subcooled water which was used by Consumers Power Company did not conform to current criteria which states that the jet half angle is not to exceed 10 degrees.

The criteria used by Consumers Power Company for its analyses is contained in Bechtel Topical Report BN-TOP-2, Rev. 1 dated September 1973.

This subject was discussed further on January 8, 1982 with Mr. Chen of the NRC.

As we noted in this discussion, BN-TOP-2, l~ev. 1 states "For subcooled water blowdown, this _model assumes a half angle approach of 10 degrees..... ".

In actuality, then, the jet expansion model used by Consumers Power Company is in complete agreement with NRC criteria, and no further action is required to resolve this question.

Robert A Vincent Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades

.- -*0202120078--820209 PDR ADOCK 05000255 P

PPR,, :.