consumers Power company General Offices:

1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-1636 January 22, 1982 D M Crutchfield, Director Operating Reactors Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PL.ANT - NUREG-0737, ITEM II.K.3.30 UPDATE David P Hoffman Nuclear Licensing Administrator Consumers Power Company letter of January 4, 1982 entitled "Consumers Power Company's NUREG-0737 Response - Palisades Nuclear Plant - December 1981 Update -

Part 2 11

, provided the status and schedule of Consumers Power Company's continuing efforts to address various NUREG-0737-items. *Upon review of this letter, Consumers Power Company has found that Item II.K. 3. 30 "Revised Small Break Loss of Coolant Accident Methods to Show Compliance with 10 CFR Part 50, Appendix K" had inadvertently been excluded.

Enclosed is Consumers Power Company's update of Item II.K.3.30.

David P Hoffman Nuclear Licensing Administrator CC Administrator, Region I.II, USNRC NRC Resident Inspector - Palisades ATTACHMENT 8201290224 820122 PDR ADOCK 05000255 p

PDR

II.K.3.30 REVISED SMALL BREAK LOSS OF COOLANT ACCIDENT METHODS TO SHOW COMPLIANCE WITH 10 CFR PART SO, APPENDIX K NRC POSITION

  • 226A The analysis methods used by Nuclear Steam Supply System (NSSS) vendors and/or fuel suppliers for small break Loss of Coolant Accident (LOCA) analysis for compliance with Appendix K to 10 CFR Part SO should be revised, documented and submitted for NRC approval.

The revisions should account for comparisons with experimental data, including data from the LOFT Test and Semiscale Test facilities.

LICENSEE AGTION As noted in Consumers Power Company letter dated December 19, 1980, we will continue to support the activities of the C-E Owners *Group in their effort to satisfy the requirements of TM! Action Plan, Item II.K.3.30 for C-E designed plants.

Numerous discussions between the NRC and C-E Owners Group have defined specific concerns to be addressed by the C-E Owners Group.

The C-E Owners Group is conducting the activities necessary to respond to these concerns and expects to submit the results to the NRC by March 31, 1982.

DEVIATION FROM AND BASIS FOR Recommendations None Schedule None REFERENCES Letter from D P Hoffman, CP Co, to D M Crutchfield, NRC, dated December 19,.

1980.

nu1281-0316j-43-142