Informs of Editorial Error in Figure 3.23-3 of 810721 Tech Spec Change Request Re Linear Heat Rate Limits,Radial Peaking Factors & Excore Power Distribution.Corrected Figure Encl
ML18046A982
Person / Time
Site: Palisades 
Issue date: 10/22/1981
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
NUDOCS 8110270138
Download: ML18046A982 (2)


Text

!n./ *~

"("'-~ *..

\\

\\."

consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Ml 49201 * (517) 788-0550 October 22, 1981

"-~*..

Director,. Nuclear Reactor R.egulation Att Mr Dennis M Crutchfield, Chief Operating.Reactors Branch No 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - EDITORIAL CHANGES TO JVLY 21, 19-81 TECHNICAL SPECIFICATION CHANGE REQUEST Cons'Umers Power Company Technical Specification Change Request dated July 21, 1981 and entitled Linear Heat Rate Limits, Radial.Peaking Factors and Excore Power Distribution has been found to*have an editorial error in the title of Figure 3.23-3.

The corrected Figure 3;23-3 enclosed for insertion into the July 21, 1981 submittal package.

Brian D.Johnson

  • .senior~ Licensing Ellgineer.

CC JGKeppler, USNRC NRC Resident Inspector-Palisades Attachment I

8110270138 0110221 '

PDR ADOCK 050002'5 p

PD~

r---__,_ _______________________________________

oc:

c
z:
z:

~ 0.9

z:

u..

0 z:

0..-

0 c(

oc:

u..

o. 8 oc:
c UJ m

c(

~

c(

0.7 0

0. I ACCEPTABLE OPERATIPN

- o. 2 0.3 o."

BREAK POINTS:

I. (. ll9' I. 0)

2. ( 1.0,.78) 0.5 0.6 0.7 0.8 LOCATION OF AXIAL POWER PEAK (FRACTION OF.ACTIVE FUEL HEIGHT)

ALLOWABLE LHR AS A FUNCTION OF PEAK POWER LOCATION FOR INTERIOR FUEL RODS Palisades Technical Specifications 0.9 1..0 FIGURE 3.23-3