ML18046A978

From kanterella
Jump to navigation Jump to search
Forwards Rept of Eddy Curent Testing,Data Evaluation & Tube Plugging,Oct 1981. Rept Describes Steam Generators Insp of Sept-Oct 1981 & Is Complete Except for Results of Dent Magnitude & Profilometry Measurements
ML18046A978
Person / Time
Site: Palisades 
Issue date: 10/16/1981
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18046A979 List:
References
NUDOCS 8110220498
Download: ML18046A978 (1)


Text

~

- "..-. I' *<...._

j consumers Power company General Offices: 212 West Mi~hlgan Avenue, Jackson, Ml 49201 * (617) 788-0550 October 16, 1981 Director, Nuclear Reactor Regulation Att Mr Dennis M Critchfield, Chie.f Operating Reactors Branch No 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR-.:20 -

PALISADES PLANT -

STEAM GENERATOR INSPECTION REPORT The attached report entitled, "Report of Eddy Current Testing, Data Evaluator and Tube Repair", dated October 1981 describes the results of the Palisades Plant steam generator inspection which took place in September and October, 1981.

The information in this report is submitted in accordance with the Palisades Plant Technical Specification 4.14.6 and demonstrates compliance with the requirements of Technical Specification 4.14.

This report is complete except the Results of Dent Magnitude and Profilometry Measurements which will be st:.bmi tted as a supplement in the very near future.

Any changes from the preliminary report have been identified by vertical lines in the margin.

Brian D Johnson (Signed)

Brian D Johnson Senior Licensing Engineer CC -JGKeppler, USNRC NRC Resident Inspector-Palisades Attachment I

7 I

8110220498 811011~ *1*

PDR ADOCK 05000255

~--,------ ____ ell~~