consumers Power co1111pany General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201 * (517) 788-0650 July 2, 1981 Director, Nuclear Reactor Regulation Att:
Mr. Dennis M. Crutchfield, Chief Operating Reactors Branch No. 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 -
LICENSE DPR-20 PALISADES PLANT Consumers Power Company submittal of May 5, 1981 requested changes to Palisades Technical Specification 4.14, 'Steam Generator Inspection Program.
Editorial changes were made to the referenced submittal by Consumers Power Company letter dated June 2, 1981.
Recent telephone discussions with the NRC have resulted in additions and changes to the original Technical Specification change request that have been agreed to by both the NRC and Consumers Power Company.
For the purposes of clarity and. expedient review the attached. change request supple-.
ment has incorporated the editorial changes plus the additions and changes agreed to during the recent NRC discussions.
The changes from the original change request are identified in the margin.
No fee for this change request is included because it is considered a part of our May 5; 1981 change request.
Brian D. Johnson Senior Licensing Engineer CC Director, Region III, USNRC NRC Resident Inspector-Palisades I