Forwards LER 80-044/03L-0
Date released: 10/31/2018 Download: ML18046A260


LER 80-044/03L-0:on 801125,closure Head Fasteners on Return Head Flange of Letdown Heat Exchanger Found Corroded.Caused by Contact W/Borated Water Leaking from Flange Due to Improper Assembly of Closure Head.Damaged Studs Replaced
ML18046A261
Person / Time
Site: Palisades 
Issue date: 12/23/1980
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML18046A261 (1)
Forwards LER 80-044/03L-0
ML18046A259
Person / Time
Site: Palisades 
Issue date: 12/23/1980
From: Frost S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML18046A259 (2)