General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201 * (517) 788-0550 December 9, 1980 Mr William RUssell SEP Branch Chief Phillips Building 7920 Norfolk Ave Bethesda, MD 20014
.e Attached is the complete list of rotat_ing equipment in the Palisades spent fuel pool area.
As we discussed on the phone J.,ast week, please replace the list previously provided to you with this new complete list.
I am sorry for the delay in compl,eting this. item.
Q~~~
f L Kuemin Seni0r Engineer Nuclear Activities CC File KUEM 33-80
- ~**
80].2].'(f@.
~ ll?t"J'l Q 1l a D:.
f
Rotating Equipment in Spent Fuel Pool Area Palisades Plant A~ Fuel Transfer Machine (pull fuel through tube)
- l. One forward wench motor; 5 hp - 1, 800 rpm
- 2.
One threading motor; 1.6 hp@ 1,725 rpm B *. Tilt Ma.chine 1..
One hydraulic pump motor {single speed AC - no SCR control); 1 hp -
1,725 rpm C.
- Pool Inspection Elevator
- l. One hoist motor (has gear reducer and transmission which is shiftable);
3 hp - l,750 rpm D.
Pool Side Fuel Handling Ma.chine
- l. Bridge drive motor; (2 each) l hp - l; 725 rpm.
- 2.
Trolley drive motor; (2 each) 1 hp - l,725 rpm
- 3.
Main hoist motor with big gear reducer; 1.5 hp - 2,500 rpm (DC)
NOTE:
A, B, C and D above are provided by Programed and Remote Systems of Minneapolis, MN and are universal motors powered by AC with SCR controls i.e., operate at various speeds.
E.
- New Fuel Inspection Machine. (elevator)
- l. One AC elevator drive motor (screw drive); 3 hp - 1,800 rpm 2.* One inspection frame drive motor (up on top with pulley and counter-weight drive).
Motor is small and has Va.riable speed control; lhp -
1,800 rpm F.
Ma.in Crane (100 ton)
- 1. Main hoist motor; 75 hp - 900 rpm
- 2. Auxiliary hoist motor; 50 hp - 1,200 rpm
- 3. Bridge drive motor; 20 hp - 855.rpm
- 4.
Trolley drive motor; 7.5 hp - l,135 rpm G.
Vent Fans
- 1. North supply fan - Main fan motor; 3 hp - 1, 800 rpm
- Filter drive motor; 1/6 hp - rpm unknown
- 2. *Exhaust fans (next to elevator shaft) with HEPA and charcoal filters
- a.
One fan motor on V8A - Belt drive; 7.5 hp - 1,725 rpm
- b.
One fan motor on V8B - Belt drive; 7~5 hp - 1,725 rpm
- c.
Roughing filter media drive motor; 1/6 hp - rpm unknown
Rotating F.quipment (Contd)
H.
Auxiliary Building Elevator Drive Motor (about 15 hp). ** Sits in block:
enclosure up over south end of Fuel Pool area; dual hp (7. 5/L 5) -.
1,045/200 rpni I. Fuel Pool TV Camera has tilt and pan drive motors; 1/16 hp - rpm* unknown 2