ML18045A906

From kanterella
Jump to navigation Jump to search
Summary of Regulatory Activities Subcommittee 800806 Meeting Re Review of Revisions to 10CFR50 & Reg Guides
ML18045A906
Person / Time
Issue date: 09/04/1980
From:
Advisory Committee on Reactor Safeguards
To:
Advisory Committee on Reactor Safeguards
References
ACRS-1771, NUDOCS 8010080154
Download: ML18045A906 (2)


Text

. \\

,,.... I 1

  • i-, e
  • l. -.. '

\\~l8Rl *00\\'lU f\\\\l tn'l I

t---~--~'

AUG 1. 8 1980

--~-

DISTRIBUTION Docket Fi 1 es Centra 1 Fi 1 es*

IE Files HAWi 1 ber Rdg Fi 1 es.

ROI Rdg Fi.l es TP Rdg Files Docket No.50-25S

-*Ma~ORANDUM FOR:. D. M~ Crutchfield, Chief, Operating Reactors Branch 5, Divisfon of Licensing~ NRR FROM:

SUBJECT:

E. L. Jordan, Assistant Director for Technkal Programs,

~iv1sipn of R_eactor Operations Inspec~ion, IE PALISADES TECHNICAL SPECIFI°CATION 3.2

.. (,l\\ITS F03084680).

In a May 5, 1980 submittal, the licensee requested a change to Technical Specification 3.2 to ~hange the*minimum level of boric acid.from 118 inches to 115 in~ches in the concentrated boric acid tank.

As n.oted in the enclosed July 25, 1980 memorandum for E. L. Jordan from D. c. BGyd on the same subject, there is a con~~rn-that the present wording

  • allows operation with only one tatik at a specified level.

This mode of operation negates the value of redundant systems.

Region III has advised tj)e licensee ~;n an fosp~ction report that the NRC position is that each tank must be at 118 inches or action statement 3.2.3 shall be met, the licensee has verbally agreed to maintain each tank at the specified level until the Technical Specifications are clarified ~ut it is going to cause an additional number of LCOs because of the a~arm position on the tank.

IE:HQ shares the concern in the memorandum and we request that Technical Specification

3.2.2.c be changed, in conjuct1on with action on the licensee's referenced request, to *require that each tat1k be at the specified level whenever the reactor is critical~ We, also, request that consideration be given to clarifying Technical Specification 3.2.3.b. su1&h that when a tank is.restored to operable status it must have a minimum s-pecified level. This concern has been discussed with.the Project Manager.

Since this item is.in our tracking*system, would you please identify your assigned TACS number and provide an est'iinated. action date for O!Jr request.

Edward L. Jordan, Assistant Qirector

.... !E~.IP.:............... fE;.IP.~AO........ _.gi~;~!~~/~ *~~:~~~.~~*~*~*~*~ ~~.~~~c~~!~~:... ~.~...... ~... '.......

c~~~~ ~~~~J~\\

01b~~ **-~or~~ci....... *::.... s,oioo... o"'\\Slf.......................... :.............................. -

t 0 0

  • o o o o*o o 0 0 0 o o o 0 o o o o o o o o o o o o o o 0 o o o o 0 0 o o o o o 0 0 I 0 o o

.- o ' o ' '

  • o o o o 0 o * *
  • o o
  • o
  • o ~
  • o o o *
  • o o o o o o o o o o o 0 o 0 o o o o 0 o o o o o 0 o 0 o o 0 o o 0 *,* o o o o o o o o o o
  • o o 0 0 o o o o
  • o
  • o o o
  • o o o o
  • o o 0 0 v

MlllC fOllM 318 (9-76) :NJlCIM! in*

.U;8. GOVllANMll\\NT PRINTING 0"'"'1CB: t 171

  • leD
  • 7el

/

D.~M. Crutchfi~ld

Enclosure:

As.stated cc:

\\

.'T. v

~ Wambach' NRR D. C. Boyd, RIII 2

. ' AUG 1 8J980 t

l l t

t I

OP'P'ICB~

-~***..**:...................... -_ **,....................o **,................., ** -..... *******................................. :................. :.....

DATii.*

                                                  • ............ ;.'._" 00 ********

. JmC POD:' 318 (9-76) NB.CK 02.CO u.a. GOVURNM*NT.P~INTtNG OP'P'ICB: 1171 - *** - 711