ML18045A758

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-18, Maint of Adequate Min Flow Through Centrifugal Charging Pumps Following Secondary Side High Energy Line Rupture. Charging Pumps Consist of One Variable Capacity & Two Constant capacity-type Pumps
ML18045A758
Person / Time
Site: Palisades Entergy icon.png
Issue date: 09/23/1980
From: Frost S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-80-18, NUDOCS 8010080592
Download: ML18045A758 (3)


Text

_I consumers Power company General Offices: 212 W!Ht Michigan Avenue, Jackson, Michigan* *49201 * (517) 788-0550 September 23, 1980 Mr James G Keppler Office of Inspection and Enforcement Region III U S Nuclear Regulatory Commission 199 Roosevelt Road Glen Ellyn, IL 60131 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - RESPONSE TO IE BULLETIN 80-18 IE Bulletin 80-18 _(Maintenance of Adeq_uate Minimum Flow Thru Centrifugal Charging Pumps Following Secondary Side High Energy Line Rupture) dated July 24, 1980 req_uested the following information:

Item 1 In a q_uanti tati ve manner similar to 1 above, determine whether or not nunimum cooling is provided to centrifugal pumps used for high pressure injection, for all conditions req_uiring SI, prior to satisfying SI termination criteria.

If a "minimum flow bypass" line is present which remains open during high pressure injection, and if that line guarantees that minimum cooling flow will be provided to the pumps under such conditions, then no further calcu-lations. are req_uired if all safety relate_d an8.lyses (Item 2.d above) assumed presence of the open line.

Response to Item 1 The Palisades charging pumps consist of one variable capacity and two constant capacity positive displacement type pumps.

The rated design pressures for the three pumps is 2135 psig as compared to the pressurizer safety valve setpoints which shows that all three safety valves are open by the 2545 psi a :pressure leYel.

Each pump also is designed with a relief v~lve on the discharge side of the pump which is set at 2135 psig and presized to pass the maximllill rated flow of the associated p'.Jlllp with maximum back pressure without* exceeding the maximum rated total head for the pump.

The Palisades charging pumps ratings and physical system design guarantee that minimum cooling flow will be provided to the pumps under any operating conditions.

'/

.~

Mr James G Keppler Palisades Plant September. 23, 1980 2

The three Palisades high pressure safety injection pumps are centrifugal pumps.

The pumps by design are provided with minimum flow orifices connected between the pump discharge and the safety injection and refueling water storage tank (SIRW tank) to insure that no damage results when operating against a closed system.

For the long term cooling case when the recirculation activation signal (RAS) is initiated, along with isolation of the SIRW tank, the pumps minimum flow return lines to the SIRW tank are also isolated.

In this case, the Emergency Operating Procedures instruct the operator as to how to assure at *least minimum flow of 30 gpm for each HPSI running.

The Palisades Plant a&ninistrative controls for RAS operating and HPSI pumps physical system minimum flow orifice design guarantees that minimum cooling flow will be provided under any operating conditions.

Item 2 If availability of minimum cooling flow for the CCPs is not assured for all conditions by the calculations in 1:

a.

Make modification*s to equipment and/or procedures, such as those suggested in the enclosure, to insure availability of adequate minimum flow under 8.11 conditions. If modifications are made as described in the attachment for interim modification II, verify that the Volume Control Tank Relief Valve is operable and will actuate at its design setpoint.

b.

Justify that any manual actions necessary to assure adequate minimum flow for any transient or accident requiring SI can and will be accomplished in the time necessary*.

c.

Veri :f"J that any manipulations required (valve opening or closing, along with the instrumentation necessary to indicate need for the action or accomplishment of the action, etc.) can be accomplished without offsite power available.

d.

Justify that flow available from the CCPs with the modifications in place will be sufficient to justify continued applicability of any safety related analyses which take credit for flow from the CCPs (LOCA, HELB, etc.).

e.

Justify that all Technical Specifica~ions based on the Item 2.d a,.nalyses remain valid.

Response to Item 2 As stated in response to Item 1, we do have n1inim1Jlll cooling flow for the charging pumps.

Therefore, this item is not applicable to the Palisades Plant.

,/

Mr James G Keppler Palisades Plant September 23, 1980 Item 3 3

Provide the results of calculations performed under Item 1, and describe any modifications made as a result of Item 2 (include the justifications requested).

Resnonse to Item 3 The Palisades Plant was in the category to perform in a quantative evaluation to determine whether or not minimum cooling is provided to the centrifugal charging pumps.

As a result of this evaluation, no modifications will be made as a result of Item 2 of this bulletin.

Steven R Frost*

Palisades Nuclear Licensing Engineer CC Director of Nuclear Reactor Regulatio~

Director, Office of Inspection NRC Resident Inspector-Palisades