- Area Code 517 7.88-0550 June.16, 1980
~rr James G Keppler Office of Inspection and Enforcement Region III U S Huclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SPECIAL RADIO-ACTIVE ENVIRONMENTAL MONITORING E:i:.'.PORT Attached is an NPDES Noncompliance Notification issued by Consumers Power Company on June 6, 1980. It is being submitted to you in accordance with Technical Specification 6.9.3.l.D.
David P Hoffman Nuclear Licensing Administrator Dir*ector, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector - Palisades JUN 1 81980
(
- F~No Pl0.2.1 IiRl&ent No:
PAL-80-05-NC37 NPDES NONCO~tPLIANCE NOTIFICATION Possible Noncompliance With Daily Average/Maximum Limitation.
June 6, 1980 Plant:
Palisades Outfall
Description:
Turbine Sump Oil Separator (000/00G)
Parameter:
Oil and Grease
- 1.
Date of Incident:
05/27/80 Permit No:
n!-0001457
- Outfall N'o:
800218 Parameter No:
00556
- 2.
Identification of specific effluent limitation exceeded:
Oil and grease shall not exceed 15 mg/l monthly average or 20 mg/l daily maximum.
- 3.
Description of Incident:
The weekly grab sample for oil and grease collected on 05/27/80 measured 84.0 mg/1.
It is believed to be a one time noncompliance.
The sample was collected on 05/29/80 to verify level below 20 mg/l.
The monthly average oil and grease was 20.7.
- 4.
Apparent Cause:
During start-up of the plant, excess oil entered the turbine sump and the filter in the oil separator unit may also have been plugged.
- 5. If not immediately corrected, the anticipated time the condition is expected to continue:
NA
- 6.
Corrective Action - The following corrective action was taken or will be taken to reduce, eliminate and prevent recurrence:
Maintenance order routed to inspect and replace (if necessary) the oil separator filter arid check remainder of system.
- 7.
Additional Comments:
NA
- 8.
Signed:
Ronald L Fobes