ML18045A218

From kanterella
Jump to navigation Jump to search
Forwards Reactor Internals Noise Monitoring Test Results. Reactor Core Barrel Tightly Clamped W/No Other Anomalous Vibrations During Testing
ML18045A218
Person / Time
Site: Palisades 
Issue date: 06/04/1980
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML18045A220 List:
References
TASK-03-08.A, TASK-3-8.A, TASK-RR NUDOCS 8006110153
Download: ML18045A218 (1)


Text

..

<I i

_\\ \\

consumers Power company-G_eneral Offices: 212 West Michigan *Avenue, Jacks.on, Mlchlg_an 49201

  • A;ea Code 517 788-0550 June 4, 1980 Mr James G Keppler Office of Inspection & Enforcement Region III U S Nuclear Regulatory Commission 799 Roosevelt Road G_len Ellyn, IL. 60137.

DOCKET 50-255 -

LICENSE DPR PALISADES PLANT - REACTOR INTERNALS NOISE.MONITORING TESTS Palisades Plant Technical Specification 4.13.D.3.requires the results of the Reactor Internals Noise Monitoring Tests to be submitted to the.NRC Region III office on an annual basis.

The results of the test demonstrates that the reactor core barrel is tightly clamped with no other anomalous vibrations occurring during the testing period.

The attached test fulfills the requirement of the subject Technical Specification.

David P Hoffman (Signed)

David P Hoffman Nuclear Licensing Administrator CG Director, Offic~ of Nuclear Reactor Regulation Dire~tor, Offic~ of Inspection and Enforcement NRC Resident Inspector - Palisades Attachment - Reactor Internals Noise Monitoring Test

-sooa11olS"'3

/loot

.s r/1