- Area Code 517 788-0550 April 22, 1980 Mr James G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - RESPONSE TO IE BULLETIN 79-03A, "LONGITUDINAL WELD DEFECTS IN ASME SA-312, TYPE 304 STAINLESS STEEL PIPE" Consumers Power Company was requested by IE Bulletin 79-03A, "Longitudinal Weld Defects in ASME SA-312, Type 304 Stainless Steel Pipe" to provide the following information:
Item 1 Determine whether SA-312 or A-312, Type 300 Series fusion welded pipe is in use or planned for use in safety-related systems subject to design stresses greater than 85 percent of the Code allowable,stresses.
For the purpose of this check the actual wall thickness of the piping products will be considered adequate if the code requirements for pressure design of the piping products are satisfied using 85 percent of the maximum allowable stress at the design temperature.
Response to Item 1 The Palisades Plant does not have any SA-312 or A-312, Type 300 Series fusion welded pipe in safety-related systems.
Item 2 For those piping components using greater than 85 percent of the allowable stresses identify the application of the piping including the system, pipe location, pipe size, pipe configuration (elbow, tee), design pressure/
temperature requirements and the manufacturer.
8004 250313
- ~----
Response to Item 2 This question is not applicable to the Palisades Plant.
(Refer to the response to Item 1.)
Item 3 2
For those facilities under construction and where access permits, the ends of all safety-related SA-312 and A-312 fusion welds should be etched to determine if CLP exists.
Identify the manufacturer and the degree of CLP as a percentage of the pipe wall thickness.
Response to Item 3 This item is not applicable to Palisades.
Roger W Huston (Signed)
Roger W Huston Senior Licensing Engineer CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector-Palisades