ML18044A286
| ML18044A286 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 11/16/1979 |
| From: | Hoffman D CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | Ziemann D Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML18044A287 | List: |
| References | |
| NUDOCS 7911270300 | |
| Download: ML18044A286 (1) | |
Text
Y.
- ~
consumers Power company Gener_al_ Offices: 212 West Michigan Avenue, Jackson, Michigan. 49201
- Area Code 517 788-0660 November 16,
- 1979 Direc-Gcr, Nuclear Reactor Regulation
- Att:
Yir Dennis L Ziema.ri.ri., Chief Operating Reactors Branch No 2 US* Nuclear RegulatorJ Commission Washington, DC 20555 DOCKEI' 50-255 - LICENSE DPR-20 PALISADES PLAN.I' STEP.11 GENERATOR INSPECT ION REPORI' The attached report entitled, "Report of Eddy Current Testing, Data Evaluator and *rube Repair", dated October_, 1979,. describes the results. 9f the Palisades Plant stean:i generator inspection which took place in September and October_,
1979.
'!'he L"lformation in this report is submitted in accordan'.ce with the Pa_lisades
. Plant Te'::hnical Specification 4~ 14.6 and demonstrates compliance with the raq_uirements of Technical Specification 4, 14 as amended October.15, 1979.
David P Hof:fm.an
.. Nuclear* Licensing Adlrinistr_ator CC: JG Keppler, USNRC