consumers Power cnmpany General Offices: -212 West Michigan Avenue, Jackson, Michigan 49201'

  • Area Code 517 788*0550 June 22, 1979 Director, Nuclear Reactor Regulation Att Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-155 - LICENSE DPR BIG ROCK PODJT PLANT MID DOCKET 50-255 - LICENSE DPR PALISADES PLANT Correction to Res~onse Dated June 14, 1979

- The following corrections for Palisades response to o_uestions of the effluent monitoring system should be noted.

Question 2 What C.etector is being used?

Palisades Resnonse should read:

1-1/2-inch sodium iodide scintillation detector, thallium activated and coupled to 1° stage photomultiplier tube.

QuestiOn 5 Calibration factor for system.

Palisades Response Indicated units of millicuries, which should read units of microcuries.

~

~- /'

/~

.. /(/~--

~£~{- '/(} ;-

David A Bixel Nuclear Licensing Administrator CC JGKeppler, USNRC