Text
{{#Wiki_filter:*. consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigar. "'*92C1.. Area CoCe 517 789-0550 May 8, 1979 Director, :Nuclear Reactor Regu1ation Att.Mr Dennis L Ziemann, Chief' Operating Reactors Br011ch ~k* 2 T3S lfuc:ea1* P.e~illa.torjr Gor!H!t~s s ion Washingtcn, DC 20555 DOCKET 50-255 - LICENSE DPR ?.l'l..LISADES PLANT - RAPID RESPONSE TO NRC FOLLOW-U? QUESTIONS CONCERNING rr.tiE TMI I.1.IJ"CIDEi:fr Consumers Power Company'*s response to NRC q_uesi:ions receivecl by telecopy on May T, 1979 are attached. These responses may not be totally complete due to the limited amount of time available to meet the NRC req_uested. May 8, 1979 suomitta.l. Consl..uners Power will oe prepared to discuss these :i.ssues at the
- May 12, 19!9 meeting in :Bethesda.
R B DeWitt Manager Production-Nuclear David P Hoffman Assistant Nuclee..r Licensir..g Afu:Jinistrator CC JGKepp1er) USNRC 79 0511 OD~-~ (
ATTACHMENT I Provide written response to the following set of questions by 5/8/79. Describe backup systems available (to auxiliary feedwater) for providing feed-water to steam generators. Discuss actions and time required to make these systems available. Are procedures available? If so, provide.
- 1.
Provide the foll9wing procedures:
- a.
Loss of offsite power.
- b.
Loss of feedwater.
- c.
LOCA (small and large).
- d.
Steam line break.
- 2.
Provide following information for PORVs:
- a.
- b.
- c.
- d.
- e.
- f.
- g.
- h.
Number. Capacity. Setpoints (open and close). Manufacturer and model. Indications of position. Record of periods isolated (isolation valve shut). Challenges during life of plant (from plant records), including performance of valve, cause of challenge. Experience of two-phase or subcooled discharge of PORVs and safety valves with description of valve performance.
- 3.
Provide indications of PORV isolation valve in the control room.
- 4.
Provide the following information on ECCS:
- a.
Initiation setpoints.
- b.
System description.
- c.
Pump performance characteristics (head curves).
- 5.
Provide reactor protection system trip setpoints.
- 6.
Provide information on charging pumps, how they relate to ECCS including:
- a.
Number.
- b.
Flow vs pressure.
- c.
Power sources and backup.
- d.
Water sources
- e.
Seismic qualification
- 7.
List all challenges (and cause) to ECCS as indicated on plant records.
- 8.
List and discuss all instances during which your plant has undergone natural circulation.
- 9.
Describe all automatic and manual features which can stop the reactor coolant pumps. 144
ATTACHMENT II
- 1.
Procedures Copies of the requested procedures are attached (Attachment III).
- 2.
PORV Information
- a.
There are two PORV's.
- b.
Each has a capacity of 153,000 lb/hr at 2385 psig. Tav 250°F Tav ( 250°F
- c.
Open: 2385 400 psia Close: not checked not checked
- d.
Manufacturer: Consolidated Dresser Model: 2 1/2" 31533VX Electromatic Relief Valve
- e.
A position switch mounted on the value is actuated when the pilot valve is positioned. See the attached drawing (950Y228, Rev. 5).
- f.
Between 1972 and 1977 the PORV's were isolated. Since 1977, the valves have been isolated whenever Tav was greater than 300°F.
- g.
These valves have never been challenged.
- h.
There are no known instances of two-phase or sub-cooled discharge of PORV's or code safety valves *
- 3.
Position indication of the PORV isolation valves (MO 1042A and MO 1043A) is provided by lights on main control console C02. A limit switch on each valve provides the input. Indication receives its power from the same source as the valve motors (480 Volt). See the attached drawings (E-242, Sh 4, Rev. 8, and E-100, Sh 1, Rev. 17).
- 4.
- a.
ECCS initiation setpoints are provided on the attached Table 3.16.1 from the Palisades Technical Specifications.
- b.
The system description is attached.
- c.
Pump performance curves are attached.
- 5.
RPS trip setpoints are provided on the attached Table 2.3.1 from the Palisades Technical Specifications.
- 6.
Charging pump information
- a.
There are three charging pumps.
- b.
The pumps are of the positive displacement type; capacities are as follows: P55A: Variable P55B and P55C: - 33 to 53 gpm 40 gpm each
( ATTACHMENT II
- 6.
Charging pump information (Cont'd):
- c.
The pumps can be powered from either station power or off-site (startup) power, with backup power supplied from the emergency diesel generators.
- d.
Water sources are: Volume Control Tank. SIRW Tank. Concentrated Boric Acid Tank (concentrated or blended).
- e.
The CVCS system is Seismic Class I (FSAR, Section 9.10.1)
- 7.
A review of records for 1977, 1978 and 1979 was conducted to determine* when safety injection was initiated. The results are tabulated below: DATES 12-18-78 1-28-79 2-2-79 . 4-7-79 4-25-79 CAUSE Low pressurizer Pressure due to rapid PCS cooldown following plant trip. REMARKS PCS pressure did not go below shutoff head of HPSI pumps.
- 8.
A record review conducted to the extent possible showed that natural circulation was used on the following occassions: DATES 8-29-74 2-10-78 4-8-78 9-24-77 11-25-77 12-11-77 REMARKS These three instances' of natural circulation occurred pursuant to the performance of a surveillance.* test (R0-8). This test is performed to verify operability of ESF equipment under postulated accident conditions. These instances of natural circulation-occurred pursuant to plant trips caused by loss of the 'R' bus. Boron sampling of the PCS under these conditions demonstrated that natural circula~ion was adequate to cause mixing of the boron.
- 9.
Primary coolant pumps can be manually stopped with hand-switches located on the control console in the Control Room, or by local operation of the pump breakers. Automatic trips are as follows: TYPE DEVICE NO PRINT NO Undervoltage 227X-l E-137, Sh 1, Sh 2 227X-2 Overcurrent 250 E-130, Sh 6 251
( ATTACHMENT II Automatic trips are as follows (Cont'd): TYPE Differential Current Ground overcurrent TITLE Primary Coolant Pumps DEVICE NO 287 250G The above-referenced drawings are attached. PRINT NO E-130, Sh 6 E-130, Sh 6 Page 3 PRINT NO E-183, Rev 4
( D4.3 PLANT OPERATING PROCEDURES LOSS OF A-C POWER This section pertains to a complete loss of outside electrical power which either results in or accompanies a plant trip from power operation. . Symptoms:
- a.
Complete power failure to most load distribution centers, start-up transforme~ power not available.
- b.
Low bus voltage indications and alarms on all bus sections.
- c.
Any or all of the following indications or alarms may be present:
- 1.
Reactor and turbine trip.
- 2.
D-C lighting energized.
- 3.
Diesel generators start.
- 4.
Primary coolant pump trips, low coolant flow alarm and trips. D4-4 Rev 18
Auto:
- a.
Turbine and reactor trips initiated if not already present.
- b.
Turbine trip signal 9r loss of standby power starts diesel generators.
- c.
Load shed relays clear loads from 2400 volt buses, if unit is tripped, standby power is lost and diesels start.
- d.
Diesel generator breakers close to energize buses, if load shed relays clear the buses.
- e.
Normal shutdown sequencer starts when diesel generators are up ~o voltage and closed to buses. Immediate:
- a.
Verify reactor and turbine tripped; manually trip if necessary.
- b.
Insure all full-length control rods are inserted into core and that reactor power is dec~easing.
- c.
Insure the following functions have occurred, initiate any that have not:
- 1.
- 2.
Normal and start-up feede.f breakers open to all 4160 and 2400 volt buses. Proper load shedding has occurred.
- 3.
Diesel generators aut.omatic start, and bus lC & 1D energized.
- 4.
- 5.
- 6.
Steam dump valves open and limiting steam pressure to 885 psig. Bypass valve closure when condenser vacuum is lost. Feed-water turbine trip on loss of condensate pumps.
- d.
Insure d-c battery power is available.for lighting, controls and vital instrumentation.
- e.
Start auxiliary feed pump turbine to return SG levels to normal.
- f.
Check status of 345 kV lines and take any action possible to restore start-up transformer supply to service.
- g.
If make up demin regeneration was in progress, manually isolate it effluent until power can be restored, to prevent contamin-ation of storage tanks. D4-5
(, \\
- Subsequent:
- a.
Verify proper load shedding of lC and lD buses and subsequent starting of service water pumps, charging pumps and cooling fans on diesel power via normal shutdown sequencers.
- b.
Establish full charging flow capability and take necessary action to restore pressurizer water *1evel.
- c. If outside a-c power remains unavailable, proceed as follows:
- l.
When diesel generator is available for further loading: {a) Insure operation of and proper pressure from turbine and generator a-c oil pumps. (b) Energize equipment as may be required for plant safety and* orderly shutdown within diesel generator load limitations. (c) Insure fuel oil transfer pumps start and verify flow to day tank. (d) Energize main turbine turning gear.
- 2.
Insure the primary coolant pump d~c oil lift pumps secure ,( automatically after five minutes operation.
- 3.
Secure the secondary system.
- 4.
Maintain steam generator water supply with steam driven auxiliary feed pumps when necessary.
- 5.
Utilize steam dump valves to control Tavg at 532°F to 535°F.
- 6.
If outage is to be prolonged: {a) Borate primary system to shutdown concentration. (b) Begin plant cooldown, and place makeup demins in service. If demins are not aYailable, and condensate storage tank is depleted, open CV bypass valves to both CST and PMW, allowing PMW to flow to CST.
- 7.
Restore systems to normal as available diesel power permits: (a) Establish cooling flow to primary coolant pumps. (b) Reenergize heat tracing on the CVCS piping. (c) Restore pressurizer level to no-load level by charging borated water. (d) M=lintain pressurizer pressure above saturation by use of heaters. D4-6
- b4*_4 D4.5
~.* Symptoms: Any one or more of the following indications or alarms may be present:
- a.
- Primary coolant pump trip.
- b.
Low flow reactor pretrip or trip.
- c.
Turbine trip.
- d.
Generator trip. Immediate: Manually trip reactor if necessary and follow up per reactor trip Procedure D4.l. Subsequent: In addition to normal reactor trip follow up:
- a.
Monitor loop flow reates, pump amperage, loop temperatures and reactor power levels for possible unstable or abnormal contitions.
- b.
Determine cause of failure before returning to power. LOSS OF FEEDWATER Symptoms: Any one or more of the following-indications or alarms:
- a.
Feedwater pump turbine driver trip.
- b.
Condensate pump trip.
- c.
i Low condensate pump discharge pressure.
- d.
Low feedwater pump suction pressure.
- e.
Heater drain pump trip.
- f.
Heater drain tank low level.
- g.
Low steam generator level.
- h.
Low feedwater flow.
- i.
Low SG level pretrip alarm (RPS). Au'to:
- . *~ :: *.:...,> il :.~ ';: :i ~.:.;, ~ ~. *--~-::*.i **~
,~*.. ~***.:
- ~*....
~~
- ~~~'(" i Several automatic functions may accompany a low feed flow situation
- a.
A condensate pump trip will initiate a trip on the corresponding FW pump turbine.
- b.
Low FW suction pressure will open full heater drain pump capacity to the FW pump suction.
- c.
Low flow FW suction pressure trips both FW pump turbines.
- d.
Reactor trip on SG low level if situation continues. Immediate: a
- If one feedwater pump or condensate pump is lost:
- 1.
Increase speed of operating feed pump to restore steam generator level. D4-:-7 Rev 20 PRC 10/4/78 AT>PR./ii .tU" I \\ c :--,.--<" ;--.,.
.2. Reduce turbine and reactor power level at the maximum rate to below 60% load. D4.6
- 3.
Trip the reactor and turbine if SG level cannot be main-tained above low level pretrip alarm and proceed with Section b below.
- b.
If all main feed flow is lost and cannot be restored, manualiy trip the reactor. Follow up trip per reactor trip _Procedure D4.l with the following additional' actions: *
- 1.
Start with motor driven auxiliary feed pump to maintain SG water level. Auxiliary feed flow must be established within 10 minutes to avail boiling the steam generators dry. Minimize cycling auxiliary flow to avoid repetitive thermal shock. NOTE: Steam generator refill rate shall not exceed 100 gpm if steam generator level :'Strip point has been experienced for ::::. 1 minute and power level was ::: 75% F.P. If prior power le~el was~ 75% F.P. refill rate may be increased to 150 gpm provided the S/G level was=:: trip point for> 15 minutes and the level must be maintained .( ~ 6%. To increase level over 6%, feed rate must be reduced to < lOOgpm.
- 2.
Secure three of the primary coolant pumps. If possible, operate pump lB or 2A for maximum pressurizer spray. Subsequent:
- a.
Continue operation of the motor or steam driven auxiliary pumps. CAUTION: Do not add f eedwater to a dry steam generator except in extreme: -emergency.. -The number -of. such cycles is very limited.
- b.
If adequate feedwater cannot be supplied or one steam generator goes dry, initiate emergency boration Procedure SOP2A.6.13 and cool do'Wn the Primary System with the water volume left. LOSS OE SERVICE WATER SYSTEMS: Symptoms: A major loss of service water would be indicated by any or all of the following:
- a.
All service water pumps tripped.
- b.
Low-pressure alarms on one or more service water headers. D4.8 PRC. 10/4/78 Rev 20 APPR /\\~ ~----;
D4.12 D4.12.l NOTE: With containment isolation in effect, charging to the plant may continue but letdown has been isolated.
- b.
Reset the high radiation and pressure circuits and check that isolation valves return to normal position after the fault causing the spurious initiation has been corrected. PRIMARY COOLANT INCIDENTS LOSS-OF-COOLANT ACCIDENT Symptoms:
- a.
Leak rate exceeds the capacity of the operable charging pumps.
- b.
Any one o~ more of the following indications or alarms may be present:
- 1.
Safety injection initiated.
- 2.
Pressurizer level low-low.
- 3.
Containment sump high level or high-high level.
- 4.
Containment high radiation.
- 5.
- 6.
Containment high pressure. Containment isolation. .I
- 7.
Thermal margin/low-pressure channel trip.
- 8.
Pressurizer low pressure.
- c.
Reactor trip indication. Immediate:
- a.
Trip the reactor and turbine if not already tripped and verify immediate shutdown. Refer to reactor trip. Procedure D4.l for initial follow-up.
- b.
Actuate the safety injection system if not actuated.
- c. If a major rupture is indicated by containment pressure and radiation:
- 1.
Insure that as a minimum: (a) Two (2) containment spray pumps or three (3) contain-ment air coolers are operating. (b) Containment spray isolation valves (2) open. (c) Noncritical service water valve (l) is closed. (d) All containment automatic isolation valves close. (e) Iodine Removal Valves Time Delay Relays operate. D4-23 Rev 13
- d.
2 *. e e Sound site emergency alarm and carry out site emergency plan as conditions warrant.
- 3.
Stop all primary coolant pumps. Insure the following minimum equipment for safety injection has operated: Equipment
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
1 HP safety injection pump. 1 LP safety injection pump. 8 HP safety injection isolation 4 LP safety injection isolation 1 charging pump. 1 concentrated boric acid pump. 1 component cooling pump. valves. valves.
- 8.
The following valves are positioned as indicated: (a) Check valve leakage pressure control (4). (b) Volume control tank outlet isolation (1). (c) Makeup stop (1) (d) Boric acid recirculation* control (2) (e) Component cooling to fuel pool (1) (f) Boric acid gravity feed stops (2) (g) Boric acid pumped fee/ stop (1) Condition ON ON OPEN OPEN ON ON ON CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN
- e.
Verify safety injection by observing flow rates and injection tank levels. As the need arises, start additional equipment in the engineered safeguards system.
- f.
After PCS pressure falls to <. 215 psig and prior to RIAS", the hand switches HS-3027 and.HS-3056 MUST be placed in the closed position.
- g.
- Iodine removal valves are open. (CV 0437A, *cv 0437B)
Subsequent:
- a.
If the recirculation actuation signal is received, insure that:
- 1.
Safety injection and refueling tank isolation-valves (2) clos~.
- 2.
Containment sump isolation valves (2) open.
- 3.
Low-pressure safety injection pumps (2) stop.
- 4.
SI pump minimum flow stop valves (2) close.
- 5.
Component cooling heat exchanger service water outlet valves (2) transfer to alternate HICs (pass sufficient water to maintain near normal component cooling heat exchanger outlet temperature). D4-24 PRC 2~/ 7 /_,_7 9"'----- Rev 22 lJ APPR_ ~\\.....-~
b
- c *
- d.
I e.
- f.
Use mot~driven or turbine driven auxi~y feed pump to maintain normal level in the steam generators. Check the primary coolant relief and safety valves and quench tank for indication of leakage. Initiate action as necessary to limit the spread of radioactive contamination. Add NaOH from make-up tank T-103 as directed by Chemistry to buffer recirculation water to a pH of,.,;7.0.
- Establish long term core cooling/flushing (to prevent B.A. precipitation in core which could interfere with proper cooling) within twelve hours of the accident by one of the following techniques:
If PCS pressure is greater than 20 psig (but less than 250 psig):
- 1)
Check that the hand switches HS-3027 and HS-3056 are in the closed position. Verify that RAS has been received and LPSI pumps have tripped, and SIRWT outlet and CV-3027 and CV-3056 have closed.
- 2)
- 3)
- 4)
Check PC temperature~saturation. Stop all but one cs pump. OPEN or check OPEN C.S. CVj3001, CV 3002 and S-DHX CV 3212 and CV 3213.
- 5)
CLOSE S-DHX CV 3223 and CV'3224.
- 6)
OPEN LPSI P67A (or B) Suction Valve from shutdown cooling 3199 ESS (3190 ESS) - preferrably P67A. CAUTION: This may be a high radiation area - if necessary, flush suction header from SIR.WT.
- 7)
Check that the air to CV 3006 is on. Then open CV 3055 'and close CV 3006 and CV 3025 (LPSI to and from S-DHX).
- 8)
Bypass RAS trip of one LPSI pump, preferrably P67A (which-ever pump whose suction to S-D Clg was opened in step 6) and start pump. Q) Verify LPSI pump flow on FI 0*302. If symptoms of pump cavitation appear STOP LPSI pump, CLOSE CV 3002, CRACK OPEN CV 3025, and place CV 3006 to AUTO, set for/\\.J2000 gpm, and then restart LPSI pump. Verify LPSI flow on FIC 0306, and slowly OPEN CV 3025 until CV 3006 is closed; ie,,....,2000 gpm going through E60B. D4-2S PRC 11/10/77 ~~--'--~-'-~~~ Rev 13
io) Open MOV 3015.-hen 'crack open' HOV 3016 (th' will require an operator at the breaker to trip the breaker, since the control circuit seals). Monitor TR 9351* for indication of flow from hot leg. Jog MOV 3016 OPEN until flow from hot leg can be verified. NOTE: If the PS 0104 interlock prevents the opening of either MOV 3015 or MOV 3016 proceed as follows:
- a.
Go inside Cl2 to terminal board 12 TV 9 (for MOV 3015) or 12 TV 7 (for MOV 3016).
- b.
Open links 12 TV 7-55 and 12 TV 9-98, scheme 167 (for MOV 3015) or 12 TV 7~55 and 12 TV 7-56, scheme 271 (for MOV 3015). NOTE: Terminals are found by counting down from the top of the terminal board.
- c.
Short terminal 12 to 13 for cable going to CO 2.
- d.
Place control switch in the open position.
- e.
When valve is opened to desired position open breaker and restore terminals on 12 TV 9 or 12 TV 7 to orginal condition. If MCC 1 or MCC 2 becomes disablea, power to MOV 3015 or MOV 3016 can be supplied.by connecting the power leads from the operable breaker to the disabled one.* This operation requires about 20 feet of three conductor #12 wire. .I
- 11)
Monitor LPSI pump discharge pressure, and FI 0302 or FI 0206 for symptoms of pump cavitation. If pump cavitation occurs, partially close MOV 3016 until cavitation.ceases. (See breaker trip requirement in 10 above.) Do not shut MOV 3016 completely. At least 100 gpm flow from hot leg is required. If cavitation persists while pumping to spray header, *or PCS pressure falls to 20,PSig, change to throttled flow to LPSI header as in Step 9.
- 12)
Efforts should be made to flush the LPSI pump (s.). when shutting down after recirculation mode of operation and during startups during recirculation *- mode.
- a.
Open SIRW outlet valve(s) by jumpering the RIAS relay(s).
- b.
Immediately after SIRW outlet valve(s) open, jumper the RIAS relay(s) to close the containment sump valve(s). D4-25a Rev 17 PRC 5/lQ/78 QA-05 APPR_Jf~.....,....~~~-*-......,_~-
- c.
Stop (start) the LPSI pump(s) after f\\J 5 minuter; run.
- d.
Remove containment sump valve(s) RIAS relay(s) jumper.
- e.
Remove SIRW outlet valve(s) RIAS relay(s) jumper after containment sump valve(s) open. If PCS pressure is < 20 psig:
- 1.
Check that hand switches HS 3027 and HS 3056 are in the closed position. Verify that RAS has been received, LPSI pumps tripped, SIRWT outlet CV 3027 and CV 3056 CLOSED.
- 2.
Check PC temperature~ saturation.
- 3.
Stop all but one C.S. pump. 4.. Check OPEN or OPEN C.S. CV 3001, and S-DHX CV 3212 and CV 3213.
- 5.
CLOSE CV 3223, CV 3224 and CV 3006 for S-DHX..
- 6.
OPEN CV 3055 and THROTTLE OPEN CV 3025 to and from S-DHX.
- 7.
OPEN LPSI pump suction from shutdown cooling - preferably JJ67A (3199 ESS) - use P67B (3190 ESS) only if P67A not operable. CAUTION: This may be a high radiation area flush suction head.er fr-om SIRWT. if necessary,
- 8.
Bypass RAS trip of LPSI pump whose suction from S-D cooling
- 9.
was opened in Step 7, and start pump. Verify LPSI flow on FIC 0306 aid adjust CV 3025 as necessary to keep flow ~ 3500 gpm.
- 10.
OPEN MOV 3015. (See e.10 above if valve does not operate.)
- 11.
'CRACK OPEN' MOV 3016. (This will require an operator at the breaker to trip the breaker). Monitor TR 0351 for indication of flow from hot leg. Jog HOV 3016 until flow from hot leg can be verified~
- 12.
Monitor LPSI pump press and FIC 0306 for symptoms of pump cavitation. If pump cavitation occurs, partially close MOV 3016 until cavitation ceases. (See breaker trip requirement in 10 above.) Do not shut MOV 3016 completely. At least 100 gpm flow from hot leg is required.
- --~:*.. ~..
~-:*.._*.....; Throttle CV 3025 if necessary to stop cavitation so as to insure flow from hot leg; ie., keep MOV at least partially OPE.:."l. D4-25b Rev. 11 PRC APPR. -....... J!
- 13.
Efforts should be made to flush the LPSI pump(s) when shuting down after recirculation mode of operation and during startup during recirculation mode.
- a.
Open SIRH outlet valve(s) by jumpering the RIAS relay(s).
- b.
Immediately after SIRW outlet valve(s) open, jumper the RIAS relay(s) to close the containment sump valve(s).
- c.
Stop (start) the LPSI pump(s) after rv 5 minutes run.
- d.
Remove containment sump valve(s) RIAS relay(s) jumper.
- e.
Remove SIRW outlet valve(s) RIAS relay(s) jumper after containment sump valve(s) open. If flow from hot leg cannot be obtained:
- 1.
Stop all charging pumps.
- 2.
CLOSE CV 3018, CV 3036, MOV 3062, MOV 3064, HOV 3066 and HOV 3068.
- 3.
CLOSE charging stop CV 2111 and all charging pumps discharge valves (2094 eve, 2100 CVe and 2106 eve).
- 4.
CLOSE charging CV 2113, CV"2115 and Pzr. spray CV 1057 and CV 1059.
- 5.
- 6.
Check OPEN 2195 CVC and 108* CVC in charging header, Room 104B
- OPEN charging CV 2111, CV 2117~ MOV 3072 and Red HPSI CV 3018 or CV 3036.
- 7.
Verify HPSI flow to pressurizer on FIA 0212, then close discharge to HPSI header (CV 3037 or CV 3059) of pump(s) pumping to pressurizer. TAKE CARE NOT TO 'DEAD-HEAD' ANY HPSI PUMPS IN DOING THIS STEP. Maintain at least one HPSI pump discharging to HPSI header. Minimum acceptable flow to pressurizer is 100 gpm. NOTE: If a break in the air line outside the containment occurs, a hose can be connected from air receiver tank T-8C to a test connection at the containment penetration. This test connection is located in the 602' pipeway above the boronorneter and is provided*with a chicago fitting. The amount of hose required is about 250 ft. Refer to P&ID M-212. D4-25c Rev. 11 I PRC 2/9 /:77
- \\\\
APPR. (j\\ ~~~
D4.12.2 1.*
- PRIMARY COOLA.i'l'T LEAK Symptoms:
- a.
eves or charging flow increases significantly above letdown flow.
- b.
Routine leak rate calculation shows an increase over normal leakage.
- c.
High rad~ation levels or alatl!ls may be observed at the following locations:
- 1.
Steam generator. blowd*own tank drain or vent.
- 2.
Air ejector effluent line.
- 3.
Component cooling system.
- 4.
Containment building atmosphere particulate or gaseous monitor.
- 5.
Containment or auxiliary building area monitors.
- d.
Any one or more of the following indications or alarms are present:
- 1.
. 2. Quench tank high level or pressure. Component cooling surge tank high level.
- 3.
- 4.
Primary relief or safety va}ve line high temperature. Primary drain tank high level.
- 5. Dirty waste drain tank high level.
- 6.
Pressurizer Jevel low.
- 7.
Volume control tank low l~vel.
- 8.
Containment sump high level.
- 9.
Containment air cooler dry pan high level.
- e.
Routine radiochemical analysis of the Steam Generator Secondary or Component Cooling System water shows a significant increase in radioactivity content. D4-25d PRC __ 2....:.=-1-* 6_77 __. ___ _ APPR. cJ: __ ~ Rev.
Immediate:
- a.
Insure that the increase in average makeup rate has not been caused by a large generator load change or by a change in Tavg
- b.
Insure the following automatic functions have occurred; initiate any that have not occurred:
- 1.
Additional charging pumps start as necessary to provide for the increased makeup requirements.
- 2.
Average makeup increases to maintain normal level in the volume control tank.
- c.
Determine leak rate by observing rate of change in volume control tank level.
- d.
- 1.
If leak rate exceeds the capacity of the operable charging pumps, immediately trip the*reactor and turbine and follow procedure for loss-of-coolant accident, D4.12.l.
- 2.
If leak rate is greater than technical specifications iimits, shut* dm*m the plant. If *iocation of leak is known, attempt to isolate affected components to reduce plant conta~ina~ion during shutdown. Subsequent:
- a.
Attempt to locate leak by:
- 1.
Radiation surveys.
- 2.
Ensuring the following valves are fully closed: (a) Pri.mary coolant safety, relief, drain, vent and samplo. valves. (b) Relief, vent and drain valves in the chemical and volume control system.
- 3.
Check all tanks listed above for increasing level.
- b. If the primary relief or safety valve high temperature alarms are actuated, the respective valve may be leaking.
- c.
Check the pressurizer level and makeup system for proper oper-ation.
- d.
If the leak is located and ~an be isolated, continue plant operation and repair the leak. D4-26
D4.12.3
- e.
If the leak was *from steam generator tube requiring plant shutdown see D4.12.5. CAUTION: Take care to insure that PCS pressure remains "' 100 ~si greater than S-G nressure until the S-G can be drained, to preclude dilution of PC with leakage from the S-G.
- f.
Establish radiological controls in the area of the leak. PRIMARY COOLMIT LEAK DUE TO CRDM SEAL FAILURE. Symntoms:. *
- a.
CRDM leak off temperatures in excess of 350°F.
- b. eves cir charging' flow increases significantly above letdown flo.;,;.. c2* t.o. 30 g~m unexplained).
- c.
Steam cloud may be visible in vicinity of reactor head on TV
- monitor~*
- d.
High humidity on detecto~ HI 1812. *
- e.
Primary or secondary indication may fail due to water on con-nectors or contacts.
- f.
High *1evel ala..--m on containm,eilt sump.
- g.
Volume control tank low level alarm. Immediate:
- a.
Insure that the increase in average makeup rate has -not been caused by a large generator load change or by a change in T avg
- b.
Insure the following automatic functions have occurred; initiate any that have not occurred:
- l. Additional charging pumps start as necessary to provide.for*
the increase makeup requirements.
- 2.
Average makeup increase to maintain normal level in the vol-ume control tank.
- c.
Determine leak rate by observing rate of cha..~ge in volun.e control
- d.
tank level.
- 1. If leak rate is greater than 2 gp~ but less than 5 gpm, re!!!ove tmit from service in a controlled r::ian..."ler at 10 1*f.-i'e per r;iinute.
D4-27
D4-.12. 4 D4.12. 5
- 2.
If leak rate is greater than 5 gpm and con.firmed to be a seal failure, trip the unit off the line after notifying load control of your intentions. Refer to Procedure D4.l
- for initial follow-up.
- e.
Trip the CRDM cooling fans to preclude d=ivi.ng *.rater spray into drive and electrical connectors. Subs~ouent:
- a.
.Borate primary system as required to insuxe cold shutdown margin . of' 2% lip *
- b.
Initiate cooldmro. of pri"'"'ry system at ma:d..nll!!l rate al.lowed in Figure 3-2 (Technical Specifications) but.not to exceed l00°F/. hour. Refer to Procedure A5.
- c.
Lower weter level in primary system to a ~oint below the CRDM seals to stop the loss of -water via the failed seal. CONTROL ROD EJECTION
- The control rod ejection is. defined as a complete severa..~ce of a control rod housing resulting in a rapid ejection of 18 inc.hes.
and followed by a sudden overpower conditi6n and loss of coolant. Syn:mtoms : *
- a.
Sudden rise in neutron channel traces to off-scale indication.
- b.
High power level reactor trip.
- c.
Containment high radiation alarms.
- d.
High start-up rate alarm.
- e.
Rapid decrease in pri.rnar'J pressure.
- f. Any or all oi' the symptoms associated with D4~12.l, loss-of'-
Coolant Accident. Immediate:
- a.
Insure reactor a..~d turbine tripped and follow up per D4.12.l, **. Loss-of-Coolant Accident. STEAM G~lERATOR TUBE RUPl'URE 7.~is procedure assunes a sudden double ended tube rupture which results _in a leak greater than chargicg capability and a consequent
- cee.ctor t:::-ip, with steam du::ip.
Symptoms:
- a.
High radioactivity alarm on the following instruments:
- l.
S~e~ gene~tor blowdow:Ll ~ouitor.
- 2.
Condenser ofr-gas monitor.
- 3.
Waste gas monitor.
- 4.
Stack gas monitor.
- 5.
Penetration and fan room area monitor
- b.
Decreasing pressurizer level.
- c.
Standby charging pumps on.
- d.
Decreasing primary pressure.
- e.
TM/T.J:J pressure reactor trip and safety injection initiation af'ter 15-20 minutes. Immediate:
- a.
Manually reduce plant load at maximum; rate which will not of itself cause a plant trip (ie, from low pressurizer pressure): turbine ramp down @r\\l 5rfo/minute. PDIL does not apply for emergency power reduction. Attempt to reduce load and remove unit from the line before tripping reactor, to minimize steam dump. Survey main steam lines to aid in determining which S/G has failed.
- b.
Take immediate action to secure plant trip. Follow-up per D4.l, Reactor Trip Procedure, with the following exceptions:
- l. Minimize use of the steam dump valves.
- 2. Trip prirnary coolant pu.~ps on the affected loop to minimize stea.~ generation.
(S/G level recordings should indicate which S/G has failed tube within a few minutes of failure.)
- c.
Secure S/G blowdowns and blowdown tanks vents to atmosphere. D4-29 Rev. 4 PRC DATE 2~~-1\\PR 1975 APPR. &J? <:;.-"'~:>
- d. *As soon as failed S/G can be identified, minimize FH flow to it (keep level @l"J 25~ following trip) to provide volume for PC leakage and prevent flooding of S/G and main steam line.
- e.
Keep a rua.in F.*1 P"~ rw4li-::..g en ~ec:i.:rc. to assist in cooling.
- f. If auxiliary FW is required, use motor driven pump only.
Subsequent:
- a. Initiate plant cooldown at a maximilln rate per operating Procedure A5, utilizing shutdown cooling as soon as possible;: to limit further steam generation.
CAUTION: Take care to insure that PCS pressure remains 100 psi greater than S/G until the S/G can be drained, to preclude dilution of PC with leakage from the S/G.
- b.
Close MSIV :fl:."om failed S/G only by opening solenoid cabinet in NE* corner of t"Llrbine building on 607 deck and:
- l. To close 'C\\T0510 from S/G A, mani.m.lly unlatch and allow to drop to the_ tripped position.SV0505B and SV0507B I 2.
To close CV0.501 from S/G B, manually unlatch and allow to drop to ** the tripped position SV0505A and svo507A.
- c. Establish radiation control zones outside the containment as deemed n.ecessary by surveys.
- d. Notify plant personnel of any restricted areas established from (c)' above.*
D4-30 PRC Ul\\TE ,.4 I 5 I 7 8 Rev. is APPR. .)\\l ~~"'
D4.9 D4.9.l I MAIN STEAM RELEASE STEAM LINE RUPTURE - INSIDE Symptoms: The following actions and alarms may indicate a steam line rupture:
- a.
Rapid drop in steam generator pressure followed by renctor trjp from same.
- b.
Containment high-pressure alarm.
- c.
Containment* isolation (eHP) actuation.
- d.
Safety injection system (SIS) actuation.
- e.
Steam line isolation valves tripped.
- f.
Sudden increase or decrease in steam flow, dependent on location* of break relative to flow element.
- g.
Rapid steam generator level oscillations.
- h.
Excessive steam/feed flow mismatch.
- i. Reduction in primary system temperature, pressure, and pres-surizer level and standby charging pump start.
Immediate:
- a.
Verify the following* functions have occurred or manually inititate same:
- 1. Reactor trip.
/
- 2. Turbine/generator trip.
- 3. Main steam isolation valves closed.
- b.
Insure safety injection actuation occurs if pressurizer low:- low pressure or containment high-pressure alarms are* present.
- c.
Secure containment sprays manually if air coolers are operating and primary system conditions are normal. Place Iodine Removal Control Valves eontrol-**Switches to "Defeat Auto".
- d.
Insure all chargine pumps are operating at maximum capacity.
- e.
If steam pressure in one steam generator continues to fall with main steam isolation valves closed indicating a break between the steam generator and its isolation valve:
- 1. Check the eves for proper initiation of boration from SIS actutation.
If necessary, initiate emergency boration Procedure B2.4.6.5 due to primary system cooldown.
- 2. Insure containment cooling is functioning properly.
- 3. Start aux. feedwater flow to the unaffected S/G.
D4-15 PRC 11/10/77 Rev 13 ~ \\._:,;-.
D4.9.2 NO~Steam generator refill rate s~ not exceed 100 gpm if steam generator level~ trip point has been experienced for ;;:.. 1 minute and power level was'.:'.:: 7 5% F. P. If prior power level was~ 75% F.P. refill rate raa.y be increased to 150 gpm provided the S/G J evel was== trip point for> 15 minutes and the level must be maintained ~ 6%. To increase level over 6%, feed rate must be reduced to < lOOgpm. CAUTION: Do not add f eedwater to a dry steam generator unless abs0 tely necessary.
- 4.
Trip primary coolant pumps to aff.ected steam generator to minimize heat transfer. Subsequent: Follow up reactor trip per reactor trip Procedure D4.l with the following additions:
- a. Maintain close watch on containment cooling system.
- b.
Continue boration to cold shutdown concentration, and complete primary system coo~doW'l.
- c.
If makeup to T2 for aux feedwater is required in greater quantity than can be supplied from the makeup demineralizers, transfer from primary storage by:
- 1.
(Gravity) Check primary.lmak~up water level higher than CST2, and open manual bypass valves around both CV 2008 and CV 2010.
- 2.
(Pumped) Check CV 2020, PMW HX inlet, valve 143 WT, and PCV 2164 3" ou*tlet valves CLOSED,. then OPEN CV 2008 and CV 2010 bypass valves and PCV 2164, and start P79A or B. Power from diesel generators for P79 may be had by manually energizing MCC3, or 4. NOTE: Backup water supply may be obtained from T-90 or T-91. (See SOP17.6.6) SECONDARY RELIEF VALVE FAILURE Symptoms: The following symptoms may indicate failure of a secondary relief or atmospheric dump valve within the valve room:
- a.
An obvious load noise level which should be audible in the control room *
- b.
Steam escaping around doors to the relief valve room and the component cooling pump room at 590' level.
- c.
Any or all of the symptoms of a steam line rupture, D4.9.l. D4-16 Rev 20 / PRC 10/4/78 APPR_;\\_,*....,..~--.--~---. ~-'--"'---~~~~~~~
D4.9.3 Immediate: In addition to the follow-up listed for a steam line rupture incident in D4.9.l.
- a.
Quickly acco1,mt for any personnel who may have been working in the relief valve room or CCH pump room. The Shift Supervisor should have this information;
- b.
Secure access to danger areas and proceed with plant follow-up to steam line break. MAIN STEAM LINE RUPTURE OUTSIDE CONTAINMENT The following procedure describes operating guidelines to lie used in the event of a main steam line rupture outside the containment, such that the steam generator content blows down into the steam line compartment at 607'. In addition, it is assumed that all offsite power sources are lost following the subsequent plant trip. For the purpose~ of this procedure, it will be assumed that the component cooling water system is ~ost due to the extreme energy imp,arted on that room from the steam line break. Symptoms:
- a.
An obvious very loud noise indic!ative of a high energy line break outside containment.
- b.
Rapid loss of pressure in one of the steam generators.
- c.
Immediate full scale steam flow indication from one of the .steam generators.
- d.
Innnediate reactor trip on low steam generator pressure (<3 seconds).
- e.
Immediate closure of main steam isolation valves, and annuncia-tion of same.
- f.
Rapid cooldown of Primary System.
- g.
Safety Injection System (SIS) initiation from low primary pressure. Innnediate (First Minute):
- a. Verify or initiate the following immediately:
- 1.
Reactor trip. ~~~.F.,._ :.. ;. ;- : ~ -:- !:.~,: -~ r;-~ '-*:,~ ':..... *.._")..
- 2.
Turbine/generator trip.
- 3.
Main steam isolation valves closed.
- 4.
Safety injection initiations.
- b.
Station an operator at auxiliary power panel to ensure emergency power.
- 1. Diesels start and come up to speed.
D4-17 PRC 10/4/78 Rev 20
L
- 2.
~tion and start-up power bus sutlty breakers all tripped.
- 3.
Automatic load shedding.
- 4.
Sequenced loading of 2400 volt buses to diesels via DBA sequencers.
- c.
Line up auxiliary feedwater to block flow to the failed steam generator by closing CV 0736 or CV 0737.
- d.
As soon as possible, start the motor driven auxiliary feed pump and provide maximum flow *to the intact steam generator. NOTE:.Steam generator ref~l rate shall not exceed 100 gpm if s.team generator level~ trip point has been experienced for > 1 minute and power level was~ 7 5% F. P. If prior power lev~l was.;::- 75% F.P. refill rate may be increased to. 150 gpm provided the S/G level was*= trip point for> 15 minute-s and the level must b~ maintained ~ 6%. To increase level over 6%, feed rate must be reduced to < lOOgpm.
- e.
Verify emergency boratio~ mode. of CVCS, and insure high-pressure safety injection pumps are operating to provide borated water . to the reactor.
- f.
If diesel 1-1 failed to sta~~. dispatch personnel to that room via outside entry iIIUilediately. This diesel will be required, for auxiliary feed flow.
- g.
Switch control room ventilation to recirculation mode. Follow-Up (First Hour): The primary follow-up action will be to insure reactor boration to cold shutdown concentration and provide adequate core cooldown.
- a.
Switch safety injection pump* cooling to service water backup supply.
- b.
Once blowdown is complete (3 minutes), dispatch operators as soon as possible to open all exterior doors to the auxiliary building.
- c.
Continue emergency boration of the reactor until boric acid tanks are drained. If PCS water level returns to normal, secure high-pressure injection flow temporarily to allow full charging of boric acid.
- d.
Operate atmospheric dumps on intact steam generator to enable controlled cooling rate allowed by available auxiliary feed flo* D4-18 Rev 20 PRC~~~i~0~/4~/~7~8~~~ APPR:__~~:~\\~\\'--'~~-=--~*--_-_*,_~~~~
D4.10 Subsequent (>l Hour):
- a.
Notify the necessary repair crews to stand by for repairs to CCW and other systems as soon as conditions allow.
- b.
If motor-driven auxiliary feed pllillp is lof;t, continue *PCS cool-do*m by intermittent charging flow and operation of pressurizer relief valve. (Open auto reliefs by pulling any two high-pressure trip bistables. Control relief with manual stops.)
- c.
All efforts at this point should be directed to restoring opera-tion of CCW system, and auxiliary feed if necessary. Proceed with inspection of auxiliary building basement as soon as possible and call in repair crews to begin work on dewatering efforts.
- d.
If it appears CCW system cannot be restored within a few days, cool system down and maintain at 212°F with steam du1nps. Begin work on an emergency tie-in to provide service water directly to the shutdown heat exchanger.
- e.
NOTE: If necessary, limited cooling to shutdown heat exchanger is available by backflow through SIS pump cooling service water backup lines. Open CV 0913 & CV 09.50 and close CV 0945, CV 0946 and CV 0910 to provide SW backflow of about 500 gpm to only the shutdown exchangers. Provide makeup to the condensate tank from demineralizer opera-tion to insure adequate long-term auxiliary feedwater supply. If this is not possible, open bypass valves around CV 2008 and CV 2010 to provide backup source from the primary makeup tank. NOTE: Backup water supply may be obtained from T-90 or T-91. (See ~Of:i.17.6.6) p-- ~...,,, I I l .::_ r..* i ~I~~" ~~.. i~ *~_;.=ai~~~*~!~ E ~~~}*i**~ MAIN FEED-WATER RUPI'URE (OUTSIDE CONTAINMENTl This procedure outlines basic operator action to be taken in the event of a main feed-water line rupture outside the containment, in particular a break between containment and the check valve in the component cooling water (CCW) room. In addition, it is assumed all offsite power is lost after the subsequent plant trip. ~toms: The follmring are probable indications of a main feed line break, in order of im~ortance: D4-196 Rev. PRC July 7, 1-975 J~~'l?l~ * /.. ) -::; ,i'/.1 / ;* I -
f-f i L : -_:"j 19 ---- ...... ':.~
~-- 19-1/2
,,__ __ ~ 1-13/16 f I I 7-3/8 3-3 B l-11 16 REF. NO.
- I IA IB IC 10 4
5 llOllENCWURE BASE ASSE*lf (NOTE 3 > LDIER iASE ' TOP rLANGE CAGE TUBE IMSEAT DISC PISTON R 1116 DISC SPRlllG llUIOE S GUIDE RETllNlllG PLUG. 1 81110£ WIET B LOC~ SCREW MTElllAL ASTl.All2 61AOE F316 STAINLESS STEEL ClllTE I & 21 ASTI A182 GRADEJl IG STAINLESS STEEL UllTE I &.2) ASTI A351 GRADE CFBI STAINLESS STEEL AISI 311 STAINLESS STEEL ASTI A565 GR. &16 STAllU.EU STfEL CM. T<.-TES I & 71 am 471 HARBEllED STAllLESS STEEL lllCOIU ALLllY l-7H STHLITE llO. G 13' ClllOll STAllllESS STEEL Tl Elll lllST.... 7 AIS I 31M STAllllESS STEEL A IS I 311ot STAllllESS STEEL
- -..b::z:c==:z:ii~ __ __il AISI '" STIHIUU llflll
.. SI 9 ST!UUSS SflEL IJSI "' STll&ESI HEEL I LllCI SCREI LOCUASllU 18 nm11* uic1 ~can 11 it TA 11111111 SCllEI LOCIUSH£R 34 2 HOLES 1-J 8 DIA. FDR CllHOUI T 25-1(1 I I __________ _J_ OIS..MJLltlG HEIGHT MI A PP~ O~ WE I GHT
- 175 LBS 17 PILOT l1s£ 13 PILll DISC 14 PILIT DISC STEI 15 l'ILDT SPllllfC 16 Sl'lllllll IASMR 11
,.LIT SUT llSllllili II SUT lllSM llS liASllET 19 SOl.EJlllt *ACli£T 78 l!llACKET STiii 11 STm INT 22 LEVEil .D .,LOU.PJI!. 14
- tWT*DR 21 UCl131T -***
21..,.El n '* ~iarun 29 Slll.EllOID 29 HUMID PUGrll IEN) 30 PLUllCER ISSEllLY HA UlllE. IQtf 30I SPRIS dill!: 31
- llll;tltll?'.
R PL!llilh llfll IS 33 SNHlll all!T 34 SOWlOID Clff!! AIJI All2... F311 SfllBUSS sun (UTE ' I 2) m* A5li Ill. 116 Silt*US SHU aa,_ 11~1 Ill STllllLHS MEl Tl EIS. HIST.* _15 lllCllllEL llLDY 1-751 AISI 303 '111111.ESS* STEEL Ali!: 11111 lllCIEL C18111111111 ALLOT AISt 304 STAINLESS STEEL 111111 WiSHli.fULEI ASTI A2 Ii GRAOC ICll Cdl!flll STEE_L \\*1~*T£1l > ASTI 1113 lillAIE. Bit lLLf1Y HEEL lSTI Al!4 SlllOE 4 ALLOY STfEi. ISTll All& 61AUE \\IC& CARD 5THL <ZUiC l'UT~D) ~ STEEL CZlllC Pi.AUi>
- AISI 418 STAllllESS Slftt. tZlllC \\IUTEPI
~STEEL (lHIC PUIU* us 1 Hf smruss sTEn l!SI Ge SIAllllESS STffl Sfi llOT£5 tARimdrm mNC. PLATfD) '151 eu STlllllESS STEEL IRlSS TUI£ lllll-Td&-5 (rlat*U 122 ill!SIC r!IK \\ZlllC "-AlEllJ ASll A Ila@ tU1111i STEEL CAllMll STEEL t FA ll!UQJ
- .mt I
I. Ull8J\\SO!UC IMSl'ECTEil l'U ENS. ll!ST. SP-2C.
- 2. 1.lllUIO P(ifHIA!!T IMSl'iCTEll PU £116. lllST. SP-23.
- 3. ll!l!IN lf.m nstlitY lltlD IS na;lllSllPAllED m EK;. ll!S!. ettr"i.
~. A&.&. EU!$ ASl SiATG!l!ll SWfA~S All£ LIMtll ~TIWIW lilil'iiiTU
- m t.ig. IMT. Sl'-23.
- 5. GE~R!L ELECTRIC PA~T 110. Cl!-95!l3-21:i CAf 385 llGillFIEO lJITll CLASS !I.
lllSllUTIGll Allt) COILS ~IT!I.lll!!IT!lll:ll £PilRY (GlPTOt\\ Tit mm lilalST!IM. & ~L"S_{PRV-I047B, PRV-\\04"! s*. P2033937 THIS VAL'IE IS IN ACCOllD~llCE I ITH DRE'SSER E?f6. INST. OS-'27 ISllE Sf IJI 111 !-li't-!1'1133WH COllSlll.IOAYEtl HECTil~TIC 11£L!Ef WAI.VE aGIU.~ "(8 llil.IMO llllllSTlllill VILV(... lllSilllElll &IYISlllli INLH: 2*1/l'" 2500# ANSI 1-111.5 SIALL UDO¥£ ALEUJlll!l!l,.lilllSIAll !EXCEPT J..l;e rtAftGE TlllCIOIESS) ~ 1-!"-~~---------"P'-------~---'I!!!"!...... OUHET: 4"" 3001' ANSI a-1&.5 SMALL 61180VE. ... VALVE CllO£: 1: _ - llO -4687 ml1eo: a-11a..J1~1cu11l-1-1FA1*1Sm
- 1
-=>
L / j _) ) <:"L05E OPGIV l/.JPl.:ATIJAJ AlAKM .-------------~-l-*--~~--~--~....;..-*J~~.. --~-~-*o_s~~PG~~E_.e_la.i_-_o~~o~v.-~_.e_,o_A_P-11 11 I (5££ UQIJ"/) P05-T POS-t 42-111 4Z*l11 ~ -z-f;£1 4Z-117 4Z*l11 -c- ~1 P~ESSURllER RELIEF /SOL, MO TOR OPERATED VALVE MO 1042A SCHEME B 177 ADAPTER TABLE PcSC~IPTIO/.J £5S.L£t1£Fl$0l, YO'. 1110104ZA 41-171 8177 P.eESS.HL/£1'.ISOl. I'"': MOI043A 4Z-ZBI "ZBI c:owo 842.8 PRIMARY COOLANT SYST!M OVE~PR(SSUR£ r~oT£CTION .SY5T~M- ~t \\ co:1" PO st* '"f0105kl fed ~t IO~Z 00 COIJT/lOl.Sl+'/Tt:H ~ G.a. TY~ c.et'l40,S'.rlAhi.eET. W1Tll 1(£Y lt£MQtll4/JtC F~ CIOJTllt a;llJTAC~ vu:r /NTU, :~ ~IJ ......--L..111 /( I( ~~8 J( J( CONT/'oCTS Fl/UY INl'U FUl.tY OPDJ Cl*._, 0--11--0 I /( o-d-o l " <>-it-o. ' _<>j_1-a " x _<>:-11---0 5 ~ o-jl-o ' IJ( 0-l - !_~_ x o-lh-II II II P05- ' SW.T'-111 D£V£1.0Pltf(Nr
- j -
/. T~QiJE sw1rcN OPCMS ON NIOt~ 70~~. &r:*r/ '.:...-.a=*-**-.:... )(J,U,l,Z~ allCHTIL COMPANY . 801 1---*-* coz c.==.J PALISADES l'lANT . Jl.,Y,l COHSUMEIS ft:M'll Cll!MPANY ' Al,ll, 11, 31!, 36 . SCHEMATIC. DIAGRAM VOLUME CONTROL SHUTDOWN CO PRESS l?a.JEF MOTOR OPERIQED VALVES
- . E--242=:
480V. A-C. l!>l.!S "'""ffi Y'I' ~- 1 1 r )---)---) S"2* CC'NTllOL .____,1--__J POWEil '80-s"20V. ~} I f I 'I~ I., J J-a '----v----' SPAIZl AUil. NOTE I \\ COIJTAC.T~
- SE!< "'=>TE FVIJIZ STAllTE!l Ut..IL51515 OTMlllWl,_5 ~ll'&CIFIEO li..I cuu.w1t..1(4 HE FOll..lilC.N 1"11.INT*
A SPAR£ N.o. Au*. Co"'T"'cT5 IN uali. '"~ BIUA1<.*1& s
- 52-o7SI, SZ-085'.S
- '"'D Si-804"'1.
- ~ov. A-C. e.us X<:>ffi
'/¢ Z,to I t t )---)--3 S'2-460 1~ 011 xl COIJTllOL __...___J r:>OwE ll u y SPA.~l AUi£. CONTACT'> ~80 V. A-C E!>U~ ... ffi y"' "i!.¢ I I I t 1 I I I I y FE.EDE~ Cll<CUIT E!>REAK.E~S '-...,-----/ 3-Tl-IEl!MAL OVllU.OAO i:il.AT.S TllRU ""CCM. OP,1.1 <>.IE CDNTACT 460 I/. />. C. l!oUS x¢ffi Y¢ l pl r t t rrr y C:-EEDE.12. Cil<CUIT F.!>IZE.AKEIZ. alCllllL COMPAllY i -. ~
- .;~~ ;
SCHE.UATIC DIA.Gil.At.A 480V. i..A.C.C. CO~f!.lt.rATT09'J RTER ~ A.C. e.. FE~DERS E: - IOO M.1wa
w I -..1 Vl TABLE 3.16.1 Engineered Safety Features System Initiation Instrument Setting Limits Functional Unit
- 1.
High Containment Pressure
- 2.
Pressurizer Low Pressure
- 3.
Containment High Radiation
- 4.
Low Steam Generator Pressure
- 5.
SIRW Low-Level Switches
- 6.
Engineered Safeguards Pump Room Vent - Radiation Monitors Channel
- a.
Safety Injection
- b.
Containment Spray
- c.
Containment Isolation
- d.
Containment Air Cooler DBA Mode Safety Injection Containment Isolation Steam Line Isolation Recirculation Actuation Engineered Safeguards
- Pi.imp Room Isolation Setting Limit 5 - 5.75 Psig
~ 1550 Psia(l) for Nominal Operating Pressures < 1900 Psia ~ 1593 Psia(2) for Nominal Operating Pressures ~ 1900 Psia _;:_ 20 R/h ~ 500 Psia( 3) (+O ~ 27-Inch (-6 Above Tank Bottom < 2.2 x 105 CPM ~ ~ (l)May be bypassed below 1600 psia and is automatically reinstated above 1600 psia. l ~ (,2 )May be bypassed below 1700 psia and is automatically reinstated above 1700 psia. ~ § (3)May be bypassed below 550 psia and is automatically reinstated above 550 psia. c+ I-' ~ 0 ~w =i I-' 'U
- i> p
!:d t_:tj CD Ul [Jl ~~ CD 1-3 c+ t-3 0 t_:tj 0 ~ CD H [Jl 0
- t. ~
0
- i Ul
'U t_:tj {ll 0 H 0 ~ H 0 -
ECCS DESCRIPTION (Response to Question 4b) Safety Injection Operation A. Normal Plant Operation During normal power operation, no components of the system are in operation, all components are on standby awaiting a safety injection actuation sigrial (SIAS) per start-up check sheet. B. Safety Injection Actuation Signal (SIAS) The safety injection signal automatically starts the high-and low-pressure injection pumps and opens all safety injection motor-operated loop valves. The system is always aligned for safety injection during power. operation. It is permissible to operate with the high-pressure or redundant high-pressure safety injection motor-operated valves in the "open" position if all of the following conditions are met:
- 1.
Approval of Management *
- 2.
Primary coolant system check valves show no adverse leakage * .I
- 3.
Sa:fety injection system check valves show no adverse leak.age.
- 4.
Relief valves RV-3165 and/or RV-3264 are.not relieving.
- 5. Pressure indicator PI 0318 or PI 0375 is monitored and readings logged hourly.
Deviations from any of these steps will require closure of the motor-operated valves and a reevaluation by Management of the situation. General:
- a.
SIAS with standby power starts all HP and LP injection pumps, opens 12 SI valves.
- b.
SIAS without standby power starts one HP and one LP SI pump ~n each emergency generator, automatically lines up SI system valves.
- c.
SIRWT level switches (LS-0327, LS-0328, LS-0329, LS-0330) actuate RAS to close tank outlet valves and recirculate from containment sump.
- d.
On primary system low pressure (240 psig),' all SI tanks drain into primary system. Four tanks of 1000 cubic feet borated water each at 1720 ppm boron.
- e.
Low-pressure safety injection standby pump starts if inactive pump set up for "standby" operation when in the shutdown cooling mode. Pump start from PS-0322, PS-0323 at 75 psig. 1
Safety Injection Operation (Contd) C. Sequence of Safety Injection With Standby Power The safety injection actuation signal operates the following equipment: NOTE: If primary system pressure decreases to 240 psig, all safety injection tanks drain into primary system. Each tank should be filled with 1000 cubic feet of borated water with 1720 ppm boron concentration.
- 1. Starts all available high-pressure safety injection pumps.
- 2.
Opens safety injection motor-operated loop valves.
- 3.
Starts both low-pressure safety injection pumps.
- 4.
Starts both boric acid pumps.
- 5.
- 6.
- 7.
8 *
- 9.
- 10.
- 11.
- 12.
- 13.
- 14.
Opens boric acid gravity feed motor-operated valves MOV-2169 and MOV-2170. Closes volume control ta.Iik outlet motor-operated valve MOV-2087. Opens concentrated boric acid pumped feed motor-operated valve MOV-2140. Starts all available charging pumps. Starts all available service water pumpsi Maintains running containment cooling fans "A" and trips fans "B." Starts all component cooling pumps. Closes boric acid makeup valve CV-2155. Closes boric acid tank recirculation valves CV-2130 and CV-2136. Closes safety injection tank test valves CV-3038, CV-3042, CV-3046 and CV-3047.
- 15.
Opens service water to valves CV-0825 and CV-0878 to engineered safe-guards room cooler.
- 16.
Closes noncritical service water header supply valve CV-1359.
- 17.
Opens component cooling water valves CV-0913 and CV-0950 to engineered safeguards pump seal cooling.
- 18.
Closes component cooling water v8.lve CV-0944A to fuel pool heat exchanger.
- 19.
Closes component cooling water valve CV-0910 to containment *
- 20.
Closes safety injection tank leak.age valve CV-3069. 2
Safety Injection Operation (Contd)* C. Sequence of Safety Injection With Standby Power (Contd)
- 21.
Opens component cooling water valves CV-0937 and CV-0938 to shut down heat exchanger.
- 22.
Closes component cooling water discharge valve CV-0911 from containment.
- 23.
Opens containment air cooler high capacity service ~ater outlet valves. NOTE: All safety injection pumps operating for approximately 20 minutes at maximum flow will reduce safety injection and refueling water tank level to 27" (7%), at which time level switches LS-0327, LS-0328, LS-0329 and LS-0330 operate the recirculation actuation signal (RAS) to operate fol-lowing:
- a.
- b.
- c.
- d.
- e.
- f.
Gives permissive to close safety injection and refueling water tank minimum flow stop valves CV-3027 and CV-3056. Trips low-pressure safety injection pumps. Opens containment sump valves CV-3029 and CV-3030. Close1s safety injection and refueling water tank outlet valves CV-3031 and CV-3057. Fully opens component cooling water inlet valves CV-0945 and CV-0946 to the component cooling water heat exchangers. Transfers control of service water discharge valves CV-0823 and CV-0826 from component cooling water heat exchdnger from hand indicating con-trollers HIC-0823 and HIC-0826.to HIC-0881 and HIC-0882.
- g.
Safety injection and refueling water tank low level alarm annunciated. D. Sequence of Safety Injection Without Standby Power The safety injection actuation signal (SIAS) operates the following equipment:
- 1.
Loss of standby power or turbine trip starts both diesel generators.
- 2.
Diesel generator running and no standby power, initiates load shedding oµ buses lC and/or lD, if associated diesel generator breaker is open.
- 3.
Diesel generator voltage normal and load shed signal closes diesel generator breaker.
- 4.
Diesel generator breaker closed clears load shed signal.
- 5.
Diesel generator breaker closed and safety injection signal starts designed basic accident (DBA) sequencers
- 3
Safety Injection Operation (Contd) E. Operation of Design Basis Accident Sequencers 1 and 3 Serviced From Diesel Generator 1-1 Time in Seconds From Diesel Generator Breaker Closure 0 2 6 9 13 20 23 40 Service Miscellaneous 480 V Loads (Valves, Etc) Boric Acid Pump P56B; Charging Pump P55C; High-Pressure Safety Injection Pump P66B Service Water Pump P7B Containment Cooling Fan V4A; Containment Spray Pump P54B if Containment High Pressure (CHP) Low-Pressure Safety Injection Pump P67B Contai1:1illent 9pray Pump P54C (if CHP) Component.Cooling Pump P52A C t C 1. Pump P52C ( i* f "A" and omponen oo ing "B" Pumps.lfail to Start) F. Operation of Design Basis Accident Sequencers 2 and 4 Serviced From Diesel Generator 1-2 Time iri Seconds From Diesel Generator Breaker Closure 0 2 6 9 13 20 23 26 Service Miscellaneous 480 V Loads (Valves, Etc) Boric Acid Pump P56A; Charging Pump P55A; High-Pressure Safety Injection Pump P66A Service Water Pump PTA Containment Cooling Fan VlA; Containment Spray Pump P54A (if CHP) Low-Pressure Safety Injection Pump P67A Two Containment Cooling Fans V2A, V3A; Charging Pump P55B Component Cooling Pump P52B Service Water Pump P7C 4
Safety Injection Operation (Contd) F. Operation of Design Basis Accident Sequencers 2 and 4 Serviced From Diesel Generator 1-2 (Contd) CAUTION: Recirculation actuation signal (RAS) will activate when safety injection and refueling water tank level reaches 27 11 (0%). NOTE: The low-pressure safety injection pumps may be used with shutdown cooling heat exchanger for emergency core cooling at anytime primary system pressure is below 270 psia. ,I 5
..(.,.. 2,00 -- -G9 *---- :... PUMP /00
COMBU'l;:,1101--.l ~N~\\"'-1~£..~t-J~ cot--145\\.)Mi;,.R Pc.)"1E.R CD. H.P. lN~E:c.\\\\C)\\o..J \\->UMP "-~ ""2...'7ail.~fL POllTU\\ND OJIE*~ON
- ----'----Q=~~~------*-----*------~~*-H:_!.1 C
- 101 l ~ ;
'I\\) I VJ
- 1.
High Power Level(l)
- 2.
3,
- 4.
Low Primary (2 ) Coolant Flow High Pressurizer Pressure Thermal Margin/Low Pressure(2, 3)
- 5.
Low Steam Generator Water Level
- 6.
Low Steam Genera.tor Pressure(2) 7, Containment High Pressure TABLE..... J.l Reactor Protective System Trip Setting Limits Four Primary Coolant Pumps Operating < 106.5% of Rated Power ~ 95% of Primary Coolant Flow With Four Pumps Operating ~ 2255 Psia PT ~Applicable Limits To Satisfy Figure 2-3 Not Lower Than the Cen-ter Line of Feed-Water Ring Which Is Located 6 1 -0" Below Normal Water Level ~ 500 Psia. < 5 Psig Three Primary Coolant Pumps Operating ~ 393 of Rated Power ( 4) (Continuous Operation Not Permitted) ~ 71% of Primary Cool-ant Flow With Four Pumps Operating ~ 2255 Psia. Replaced by High Power Level Trip and 1750 Psia. Minimum Low-Pressure Setting Not Lower Than the Cen-ter Line of Feed-Water Ring Which Is Located 6' -O Below NorinE..l Water Level > 500* Psia. < 5 Psig (l)Below 5% rated power, the trip setting may be manually reduced by a factor of 10. Two Primary Coolant Pumps Operating . ~ 213 of Rated Power(4) (Continuous Operation . Not Fermi tted) ~ 46% of Primary Cool-ant Flow With Four Pumps Operating ~ 2255 Psia Replaced by High Power Level Trip and 1750 Psia Minimum Low-Pressure Setting Not Lower Than the Cen-ter Line of Feed-Water Ring Which Is Located 6 1 -0" Below Normal Water Level ~ 500 Psia ~ 5 Psig (2 )May be bypassed below lo-4% of rated power provided auto bypass removal circuitry is operable. For low power physics tests, thermal margin/low pressure and low steam genera.tor pressure trips may be bypassed until their react points a.re reached (approximately 1750 psia and 500 psia., respectively), provided auto-matic bypass removal circuitry a.t lo-1% rated power is operable. (3)Th and Tc in °F. Minimum trip setting shall be 1750 psia for two-and three-pump combinations" For four-pump operation, the minimum trip setting shall be 1650 psia. for nominal operating pressures less than 1900 psia; and 1750 psia for nominal operating pressures 1900 psia and greater. (4)operation with two or three pumps is permitted to provide a limited time for repair/pump restart, to provide for an orderly shutdown or to provide for the conduct of reactor internals noise monitoring test measurements
AUTO Tl?IP ~LARM'i SEE. owe:,. ~-"291 OVE!t-LOAO
- 1 2s2.10~
r !>12S.ll-IO!>
- f-.,..,o*
lm!~l'2t:: I
- 'Z
~0.111 I .J.P'i-Ci +01nA . I 9 I 1=011. llllTIRNAL I II I ~ME.i.AATIC J51&<} . ~IAC,IZA.M. SH I II I owe;. *E-1~0 {>
- sw.
- I 1Fs-'
I !0~~1 I I* J3*s4 I I nn~ 'A21 c;Ql ( £Q! + n'm} 4o J111s<} ~ SG ~ ~G nw} ~ I
- CLOSE. --= I "-00-.J c;ll££1J IMO LT ----<>- ~ -<>-----c=:O T'l,I P
'Z ----"'W.--.,_-.J IT 217ll*I Pl211..AAIC!Y COOl..Alo.JT PUl'..IP f:> '50A. -:.c.MU.A& A"210S -lo~ r.>lTAILS Slli OWG. i*l!>O SMUT b I 7S:~03 C.s s S1 !'ZS'Z~03 S&t PUMP' PSOA MOTOIZ. SPAC:£ 1-1£ATEIZ. EVENTS llt,OllOEll 1*--l SEE OW(i.I E*'Z9B c~v) co... TAC.TS MANOL£ Et.ID o-l,_..;~ I 'Z
- -Iii o-111 3
+ POSITIOl..I~ 'Losi t.IOIZt.A UTill. TIZI.. ,~11* x x x 731 2S'Z*10ll o-1i-J o-ll-4 i " x "If. I:> COl..ITROL SWITCH '2.S2-IO:!I c.s G.E. T"T"Pli:. Sl!.M, LOCATION C.07 IJOTE
- SEE. owe:. E-1&~
I. ALL WllZ&S "14 A.W.G. &llCliPT A~ l..IOTiO 'Z. c:'OR PllO.,IMIT't 1..IC:MT C.ll~CUIT SE.II; r.>wc;. i -97, SH. o HCHTIL co**Aln SCl-JEMATIC DIAC.Q.A..M PIC.IMARY COOLAIJT PU~PS 6:.- 183
I I I I I I / !.~,r-I I I
- I
'1... I - .. f . I ~ ~ ~ SI ~ ' ~ <, ~ ~ () \\J ~ ~ I 13 '"~---.J
- ' *g'*.**.,
CS*I. C:~*~
- I lzso-1
- 1s1o1 C:$*1 r11-r cs-~
'Z ~----=+--__J l.'iO*HD ~ 10 5 rps TPS ' 'I ~------' " \\ '. I .J ~ 17 5 T/05 "~Cl.WO OV~'{(U~lo..i=~-r ( zso t;) ,----------oPI~ 1 2 II TPS 9 ~ cs*. I OVE,fCtlMf!JN( RE!.AY rest CS T6R.N/NAl.1 1 TPS 1111 86----__J l(r /4 .L Z81 t.J _Z.51 '11 I n I l i \\ I 116----~ TPS \\ TPS 011'."<!'R<!'NT'.U. eE:..AY.,.EST TER.<"VA'- ~-----t----._.----'-"'+-------""-+---~1-----=:.i---____!_~--*-~'e:.i___ 1a1 --o IZ ~
- ~
.,., 1 Ir. Z51 llJ ~ ~,--" ~1si")I ~ l(J, 18 \\ ?i-- Z50G 0' --
- ---<>---------1~-------4>-~------{----------!--
SP""'<!' C VEI( l.OA 0 A/AKAf 1 .s ~p~~+ i:::+/-
- . !Nl*1---...,.----...,.-...,.-------,.------------------...J NO Te 4-IGO V MOTO.~.r:Et:OER
~--**---
QV~~CUR1?NT; ~OIFFE~ENTIAL TRl.0 Cl~Cl/lT /. 01.r::.r::Eee.Y"""'- l(E:.AY 'z81-U500NP.RJ.VARr CCCLANr ?'/A.II~
- EED 13KR"S CNl.Y
( ZSZ*tr~ :1c~. -~03; *~o*j \\ \\ \\ lllCM.IHONE HCHllL COMPAMY SCHeMATIC" DJA(;RAM SOt..E.VOID OPeR.4T6D CIRCU/ T MEAKER
- I I
UNDeR1IC£ 'AIJ.r= R~~.J>' T"P.o<fo 13uS 1' '1) 1211*-c:: '""A) I =~ NCTION . 'Ill' I I *----..**---*- tr*l8, i I I I
- * '"' '"4~e OF C045Toow"'
tlNOE~VOl..TAfi£ ALI_._ J{ELA':f TA.6LE HC*TIL COMPANY .'I; .,~ .. ~.. ~~~- - ~.. \\;,. "':'"
- 1r1_--..
SCl-IEMA.TIC OIAG~A.M '140011. I 41~o v. &us 1.JN0611t.- VOLTAGE, l.OAr.:> SNaOOINCi
11\\.ii;). LT. ( C<>Nr,<.Jc .C'OJ.l\\tCR SUS LJ,V ON) {'f:LAY\\; r--*- +-------* l.OAO Lo-~ 0 SHEl:JOl""1C, ':;:Ht;OOING C'NTqo( ow~ . ~E'-A'>'~ UN0£1;"'*t-* -+----** *--. * *--+-1*----+r-ALA..:Mlio LOA.O p r,H:::D-)>*-----------[-----~ 1 1 7 A_ll Pl -<>CO"" 177*/ T -I 240011 s;.iEo. '3US C.OA/TlloL u.v. ow11.orr J
- ?4*All I
I/ .t.n II P//A C041.b KY 12 7-1 Yl 1 s27*1 II )( 2 Tisr I S"' c;~~,1 -ztt440-I C04Lr PZ - o~ . 11 I -1211(-5 II co" 94 t 9 1117"* '1.,... /(}t /2 ~i All (5 llEQ"O) O,.; SC,.U!M~> AI005 ~* A,006 0#.Jt.Y l!I 2' IZ /1094 5 / ~])( 1~7 rz lfH. 174-All
- II IC*
108 /!I ~
- 14 25 I
I/ 94-NII All A.II N ~(-lC])...,_.>----+---~r-,+---0-Al/I 3 4 1----------
l 2../-KV e.us AJO. JC UNOERVOLTAC:.E ~ LOAO SJ.IEOO!NG _E§LA'YS SCWEMI! A/00~
AJO. U>C AIO. ~,. LOC 1n-z >.12 mx-21,2,1.12 194-11 A11
- ~~~~.°."!..
127-3 Al! IZ1i* 3 Al! 1 z1.1 A21 n1X*I A21 INTElll.OC.KfN(;,..ELAYS NO. LDC NO. l.OG 1440-1 Gilli. rnx.;;:ca.1. /4>#0*? C1SC *77W*D C04 ?17*-'iA"ZZ COAJTllOL INO 6u'::o</a.4:~,1A~~""'l*1."'J.;~ !'Wll.. u.v. LDC NO. LDC. 1'4. All GO.L 17'*Al2 C04R. C04 C04L -_J C04 277-o/XY'; /YZ;/lx AU. l~/3
- PUA, NII C04 SCUiMi A*ooi; (SIMtt.All ~Oi(.
SC.,.,EMi.41001) t NOTi:!; i:-01~ ~ELA";/ TA 6 ~ i S, St:t: SHcE,- 2 (_,,:: r.11<;, OYVC,. ?. !>t!PA~ATE f.ZAC..c.VAY s..,,sTcM '""*NII Cl~L p,,A,f'tJ/11 <>1,9~ SC...,6Mii AIOOb (l.;orE 2} NON 11S1tiiJ I..QAaTKt#
- ICllTIL coa*&llY SCl*Ui.MAT!C. OIAGlfAM
'Z~OOll. ~.//(r.Oll. a.us U/.JO*R-VOt.7.AGe J1 LOA t;, :Sl-J*E.Ot:>l"-IG .....}}