General Offices: 21!2 West Michigan Avenue, Jackson, Michigan 49:201
- Area Code S17 788*0S60 April 6, 1979 Mr Jam.es G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SPECIAL NONRADIOACTIVE ENVIRONMENTAL MONITORING REPORT Attached is an NPDES Noncompliance Notification issued by Consumers Power Company.
It is being submitted in accordance with Technical Specification 6.9.3.1.D.
David P Hoffman Assistant Nuclear Licensing Administrator CC:
Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement 79042302*.:5"
.)
6.4-"IJ*'-**
Incid~nt No PAL~79-03-NC26 NPDES Noncompliance Notificalton Apparent Noncomplia.a.ce with Daily Avera.gc/Ha.."<imum Limitation March 27, 1979 Date Outfall Description Discharge To Lake Michigan - 001
=----------"'----~
Permit No MI 0001457 Outfall No 800095
~-.;..:;.... ___ _
Parameter No 00400 Parameter pH
~--------~
- l. Date of Incident 3/?J,/10
__..,......,~---------
- 2. Identification of s~ecii'ic effluent limitation exceeded:
J;>H 6.5 to 9.5
- 3. Description of Incident:
Noncompliance lasted 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> starting at 2400 hours0.0278 days <br />0.667 hours <br />0.00397 weeks <br />9.132e-4 months <br /> 3/20/79.
the pH of discharge water to the lake during this time was calculated at 5.2 J;>H.
- 4.
Apparent Cause:
Operator error - a valve was inadvertently left open at the end of the shift.
This valve a.l.l.c;wed water to flow to* the neutralizer tan.~. The tank overflowed and its contents at pH of.2.5 were released to the mixing basin at about 150 g_'O!!l for approxi~.ately 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
- 5. If not immediately corrected, the a.o.ticipated ti:ne the condition is e.."qlected to contim:.e:
NA
- 6.
CorrectiYe Action - the following corrective action was te-lten or will be taken to reduce, eliminate a.zld prevent recurrence:
- 7.
- 8.
After shi~ change, upon discovery of condition, the release was terminated.
Procedures for system operation will be reviewed with persons involved.
Additional. Corr.:uents:
NA
'19042802
~o Signed:
RI.Fobes
-?"...,
/ ~ r-
/A I
./
./ ta~-d',.(_ r~