consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201
- Area Code 517 788-0550 February 28, 1979 Mr James G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
ANNUAL REPORT COVERING OCCUPATIONAL EXPOSURE DURING 1978 Attached is the annual report covering occupational exposure during 1978, as required.by Technical Specification 6.9.1.b.
David P Hoffman (Signed)
David P Hoffman Assistant Nuclear Licensing Administrator CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement 790305 o~c;,
1978 APPENDIX A STANDARD FORMAT FOR REPORTING NUMBER OF PERSONNEL AND MAN-REM BY WORK AND JOB FUNCTION Number of Personnel (> 100 mrem)
Total Man-Rem Contract Contract Station Utility Workers Station Utility Workers Work & Job Function Emplo;y:ees Emnlo;zees and Others EmJ2lo;zees Emplo;zees and Others Reactor 012erations & Surveillance Maintenance Personnel
.515
.926
.132 Operating Personnel 27 2
16.256
.099
.623 Health Physics Personnel 8
16 12.199
.307 12.333 Supervisory Personnel 6
2.424
.328
.261 Engineering Personnel 5
2.654
.422
.061 Routine Maintenance Maintenance Personnel 36 90 12 96.565 173-563 11.164 Operating Personnel 4
2.141
.234
.119 Health Physics Personnel 6
1.574
.155 Supervisory Personnel 12 8
28.255 5.498
.140 Engineering Personnel 3
4.160 2.433 3.436 Inservice Insnection Maintenance Personnel 3
10 15 1.672 7,984 23.917 Operating Personnel
.257
.210 Health Physics Personnel
.285
.014
. 325 Supervisory Personnel
.151
.025
.041 Engineering Personnel 3
4 4
2.237 2.615 6.944 Special Maintenance Maintenance Personnel 4
94 43 4.003 143.105 90.676 Operating Personnel 1.286
.018
.090 Health Physics Personnel 10 18 1.209
.026 6.327 Supervisory Personnel 9
4
- 1. 793 1.888 1.028 Engineering Personnel 7
5.364 4.426 6.039 Waste Processing Maintenance Personnel
- 1. 362 1.162
.024 Operating Personnel 7
2.425 Health Physics Personnel 3
.442 Supervisory Personnel
.098 Engineering Personnel
.212 Refueling Maintenance Personnel 5
5 3
6.291 6.102 1.090 Operating Personnel 20 13.133 Health Physics Personnel 6
.812
.378 Supervisory Personnel 7
2.331
.187 Engineering Personnel 1
2.922
.144
.613 TOTAL Maintenance Personnel 48 199 73 110.408 332.842 127.003 Operating Personnel 58 2
35.498
,351 1.042 Health Physics Personnel 33 34 16.521
.347 19-518 Supervisory Personnel 34 8
4 35.052 7.926 1.470 Engineering Personnel 19 4
4 11.549 10.040 17.093 GRAJ'ID TOTAL 192 211 117 215.028 351.506 166.126 1.16-7