ML18043A364

From kanterella
Jump to navigation Jump to search
Forwards LER#78-041/01T-01
Date released: 10/31/2018 Download: ML18043A364


LER #78-041/01T-01 on 781214:insufficient HPSI Flow Would Reach Core During Postulated LOCA Due to Redundant HPSI Header Being Valved Out of Svc Because of HPSI Pump NPSH Considerations. Mod Is Being Considered
ML18043A365
Person / Time
Site: Palisades 
Issue date: 12/26/1978
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
References
Download: ML18043A365 (3)
Forwards LER#78-041/01T-01
ML18043A362
Person / Time
Site: Palisades 
Issue date: 12/26/1978
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML18043A362 (1)