ML18039A894

From kanterella
Jump to navigation Jump to search
Forwards LER 99-008-00,concerning HPCI Sys Being Declared Inoperable,Iaw 10CFR50.73(a)(2)(v).There Are No Commitments Contained in Ltr
Date released: 09/27/2018 Download: ML18039A894


LER 99-008-00:on 990905,HPCI Was Inoperable Due to Failed Flow Controller.Caused by Premature Failure of Capacitor 2C3.Replaced Controller & HPCI Sys Was Run IAW Sys Operating Instructions
ML18039A895
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 10/08/1999
From: Moody G
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18039A895 (10)
Forwards LER 99-008-00,concerning HPCI Sys Being Declared Inoperable,Iaw 10CFR50.73(a)(2)(v).There Are No Commitments Contained in Ltr
ML18039A893
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 10/08/1999
From: Herron J
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18039A893 (6)