Requests NRC Review & Approval of Plant Revised Relief Request 3-ISI-1 & Provide Util Response to NRC Comments Documented in Ltr to Util
ML18039A245
Person / Time
Site: Browns Ferry 
Issue date: 02/17/1998
From: Abney T
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9802240153
Download: ML18039A245 (8)


Text

A I

T NOTES:

L CATEQORY 3

-.REGULAR

~CY INFORMATION DXSTRIBUTIOA SYSTEM (RIDS)

ACCESSION NBR 9802240153 DOC.DATE: 98/02/17 NOTARIZED: NO DOCKET FACIL:50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILXATION ABNEY,T.E.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Requests NRC review

& approval of plant revised relief request 3-ISX-1 E provide util response to NRC comments C

documented in ltr to util dtd 980708.

DISTRIBUTIQN cQDE: A047D coPIEs REUEIUED:LTR

)

ENcL I

sjzE: 5 7 TITLE: OR Submittal: Xnservice/Testing/Relief from ASME Code - GL-89-04 RECIPIENT ID CODE/NAME PD2-3 DEAGAZIO,A COPIES RECIPIENT LTTR ENCL XD CODE/NAME 1

1

~

PD2-3-PD 1

1 COPIES'TTR ENCL 1

1 G

0 INTERNAL: ACRS XGZ." CENTER 01 NUDOCS.-ABSTRACT RES/DET/EIB TERNAL: LITCO ANDERSON NRC PDR 1

1, 1

1 1

1 1

1 1

1 1

AEOD/SPD/RAB NRR/DE/EMEB OGC/HDS3 RES/DET/EMMEB NOAC 1

1 1

1 1

0 1

1 1

1 D.

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTALYNUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 13

0

Tennessee Valley Authority, Post Oftice Box 2000, Decatur. Alabama 35609 February 17, 1998 10 CFR 50.55a (a) (3) (i)

U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket No. 50-296 BROWNS FERRY NUCLEAR PLANT (BFN)

UNIT 3 REVISED RELIEF REQUEST 3-ISI-1 REGARDING REACTOR PRESSURE VESSEL (RPV)

SHELL WELDS AUGMENTED AND AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)

SECTION XI INSPECTIONS AND TVA' REPLY TO NRC '

LETTER DATED JULY 8 r 1 997 The purpose of this letter is to request NRC's review and approval of BFN's revised relief request 3-ISI-1 and provide TVA's reply to NRC's comments documented in a letter to TVA dated July 8, 1997.

TVA's letter to NRC dated January 22,

1997, contained the original relief requested 3-ISI-1.

NRC denied this relief request and documented four reasons for the denial.

TVA's revised relief request provides supplemental technical justification based on industry initiatives and information to aid NRC to reconsider granting BFN relief.

In addition, TVA's reply to NRC's comments regarding the original relief request is provided in Attachment 4 of the enclosure.

The revised relief request asks relief from the RPV examination requirements of the ASME Boiler and Pressure Vessel Code Section XI, 1989 Edition.

Specifically, in the enclosure, TVA requests relief for one operating cycle from performing the reexamination of the Unit 3 RPV circumferential shell weld flaws.

This examination is required to be performed during the Unit 3 cycle 8 refueling outage scheduled for October 1998.

tt802240 g,"0500029b 15'80247 pop AOQCK pDR 8

IIIIIIIIIIIIIIIIIIIIII IIII IIIIIIIIIIII

if'l~

ik~

U.

S. Nuclear Regulatory Commission Page 2

February 17, 1998 The BFN Unit 3 code of record is the ASME Section XI, 1989 Edition (no addenda).

The proposed relief request is in accordance to the provisions of 10 CFR 50.55a (a)

(3) (i) and consistent with information contained in NRC Information Notice (IN) 97-63, "Status of NRC Staffs review of BWR Vessel Internal Project BWRVIP-05".

Also, this relief request is consistent with the industry initiative contained in the BWRVIP-05 document, BWR Vessel and Internals, BWR Reactor Pressure Vessel Shell Weld Inspection Recommendations.

TVA performed the BFN Unit 3 RPV examination and the shell welds augmented examination during the Unit 3 extended outage (Fall 1993).

The examination results revealed that four of the RPV shell welds had flaw indications that exceeded the allowable ASME Section XI Code acceptance criteria.

TVA analyzed the indications and determined that BFN Unit 3 could safely be returned to service.

The ASME Section XI Code requires RPV shell welds with flaws that were evaluated as acceptable.

"as is" be reexamined during next three inspection periods.

To meet this requirement, TVA must reexamine the Unit 3

RPV shell welds flaws during the cycle 8 refueling

outage, unless relief is granted.

TVA includes in the enclosure the revised relief request 3-ISI-1 and supporting technical justification.

This justification supports TVA's position that successive examinations of the Unit 3 RPV flaw areas are not warranted and could be delayed for several operating cycles.

At this

time, TVA only requests to delay the RPV examinations one operating cycle in order to help expedite NRC's review.

This relief request is similar to Hope Creek's relief request submitted to NRC on August 29,

1997, and NRC approved on October 31, 1997.

TVA's reply to NRC's four denial comments regarding the original 3-ISI-1 relief request is provided in the enclosure, Attachment 4.

TVA requests NRC's review and approval of the revised relief request 3-ISI-1 by May 1, 1998.

If relief is not granted, TVA will have to perform the RPV welds examination during the Unit 3 cycle 8 refueling outage and will also have to pursue fabrication of special inspection tooling to conduct 'the examination.

~i 4i

~

~

il~

il>>

~

I il~

U.

S. Nuclear Regulatory Commission Page 3

February 17, 1998 There are no commitments contained in this letters If you have any questions regarding this matter please telephone me at (205) 729-2636.

S'erel Abn Manager of Li nsin and Indust y Affai s Enclosure cc (Enclosure):

Mr. A.

W.

De Agazio, Project Manager U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Mr. Mark S. Lesser, Branch Chief U.S. Nuclear Regulatory Commission Region II 61 Forsyth Street, S.

W.

Suite 23T85

Atlanta, Georgia 30303 NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road
Athens, Alabama 35611

II i~

~

~

il~