Forwards LER 97-005-00,providing Details Concerning auto- Start of Engineered Safety Features.Event Resulted from Inadequate Procedure in That Procedure for Developing Post Mod Tests Did Not Require Task Risk Review
Date released: 09/27/2018 Download: ML18038B985


LER 97-005-00:on 971012,ESF Components Were Actuated.Caused by Inadequate Procedure.Cs Pumps Were Secured & Injection Valves Were Closed & Refueling Floor Activities Were Stopped
ML18038B986
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/10/1997
From: Jay Wallace
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18038B986 (14)
Forwards LER 97-005-00,providing Details Concerning auto- Start of Engineered Safety Features.Event Resulted from Inadequate Procedure in That Procedure for Developing Post Mod Tests Did Not Require Task Risk Review
ML18038B984
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/10/1997
From: Crane C
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References