ACCESSION NBR:9710150169 DOC.DATE: 97/10/14 NOTARIZED: NO DOCKET FAGIL:50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 50-296"Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILIATION AUSTIN,S.
Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Forwards Encl 7 which was issued w/proposed TS Change 384 re power uprate.Encl commitments made by util.
DISTRIEUTION CODE:
AOOID COPIES RECEIVED:LTR l
ENCL I
SIZE:
TITLE: OR Submittal: General Distribution NOTES:
RECIPIENT ID CODE/NAME PD2-3 WILLIAMS,J.
COPIES LTTR ENCL 1
1 1
1 RECIPIENT ID CODE/NAME PD2-3-PD COPIES LTTR ENCL 1
1 E
0 INTERNAL: ACRS NRR/DE/ECGB/A NRR/DRCH/HIPB NRR/DSSA/SRXB OGC/HDS3 EXTERNAL: NOAC 1
1 1
1 1
1 1
1 1
0 1
1 E CE 1
NRR/DE/EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR 1
1 1
1 1
1 1
1 1
1 D
U NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)
ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:
LTTR 14 ENCL 13
Xnformal ioPiy/p To:
Document Control Desk US NRC am sending you Enclosure 7 to TS Change
- 384, Power Uprate that was issued from Browns Ferry Nuclear Plant on Dockets 50-260 and 296.
Please add this page to your package Steve Austin 97iOi50i69 9710i4 PDR ADQCK 05000260 P
e
ENCLOSURE 7
TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 2 AND 3 PROPOSED TECHNICAL SPECIFICATION (TS)
CHANGE TS-384 LIST OF COMMITMENTS Commitments 1 through 3 will be completed for Units 2 and Unit 3 prior to implementation of the power uprate on that unit.
- 1. Evaluations will be conducted to insure that the safety related electrical equipment required per 10CFR50.49 is properly qualified for the normal, abnormal and accident conditions postulated at uprated conditions.
- 2. NPSH evaluations for uprate will reflect the conditions present at the time uprate is implemented.
The final conclusions regarding ECCS NPSH will be formulated in accordance with the methodology and schedule for NRC Bulletin 96-03 and anticipated NRC guidance.
- 3. Motor operated valves which experience new conditions as a
result of uprated power will be evaluated in accordance with Generic Letter 89-10.
- 4. TVA will issue a
TS change detailing equipment and setpoint changes made as a result of utilizing the GOTHIC computer program for EQ modeling.
TVA expects to issue a
TS change to NRC detailing these changes by first quarter of 1998.
- 5. Startup/Surveillance testing will be conducted to demonstrate the ability of plant systems to perform their designed functions under uprated conditions as defined by the start-up test program.