ML18038B269

From kanterella
Jump to navigation Jump to search
Forwards LER 95-003-01 Re Main Steam Safety/Relief Valves Exceeding TS Setpoint Limit During Tests
Date released: 09/27/2018 Download: ML18038B269


LER 95-003-01:on 950207,MSSV Rv Exceeded TSs Required Setpoint Limit Resulted from SRV Pilot Disc/Seat Bonding. Retested out-of-tolerance Valves & Recertified
ML18038B270
Person / Time
Site: Browns Ferry 
Issue date: 05/04/1995
From: Hsieh C
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18038B270 (10)
Forwards LER 95-003-01 Re Main Steam Safety/Relief Valves Exceeding TS Setpoint Limit During Tests
ML18038B268
Person / Time
Site: Browns Ferry 
Issue date: 05/04/1995
From: Machon R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18038B268 (6)