Text

PRIDRI EY 1

ACCELERATED Rl DS P l<OCI;SSliG)

REGULATORY INFORMAT1ON DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9505020308 DOC.DATE: 95/04/28 NOTARIZED: NO DOCKET I FACIL:50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 AUTH.NAME AUTHOR AFFILIATION MACHON,R.D.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards LER 95-004 re details concerning reactor scram that resulted from personnel error.

DISTRIBUTION CODE:

IE22T COPIES RECEIVED:LTR l ENCL

(

SIZE:

~ + 7 TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.

NOTES:

RECIPIENT ID CODE/NAME PD2-3-PD INTERNAL: ACRS AEOD/SPD/RRAB NRR/DE/ECGB NRR/DE/EMEB NRR/DOPS/OECB NRR/DRCH/HICB NRR/DSSA/SPLB NRR/DSSA/SRXB RGN2 FILE Ol EXTERNAL: L ST LOBBY WARD NOAC MURPHY,G.A NRC PDR COPIES LTTR ENCL 1

'1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME WILLIAMS,J.

A 0 B

LE CENTE NRR/DISP/PI PB NRR/DRCH/HHFB NRR/DRCH/HOLB NRR/DS SA/S PS B/B RES/DSIR/EIB LITCO BRYCE,J H

NOAC POOREIW NUDOCS FULL TXT COPIES LTTR ENCL 1

1 2

2 1

1 1

1 1

1 1

1 1

1 1

1 1

1 2

2 1

1 1

1 YO1'E TO ALL"RlDS" RECIPIENTS; PLEASE IIELP I:S TO REDUCE O',KSTE! CONTACT I'IIE DOCL'iICYTCOiTROI.

DESh, ROOXI Pl-37 (EXT. 504-20S3

) I 0 I LIXII%ATE>OL R XANILIPI<Oil DIS'I'RIBLt'I'IONLIS'I'S I'OR DOCL'ill'.i'I'SYOL')Oi"I'lI I')!

FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED:

LTTR 27 ENCL 27

4I f

Tennessee Valley Authority. Post Office Box 2000. Decatur. Alabama 35609 April 28, 1995 U.S. Nuclear Regulatory Commissi'on ATTN:

Document Control Desk Washington, D.'C.

20555

Dear Sir:

10 CFR 50.73 BROWNS FERRY NUCLEAR PLANT (BFN) - UNITS 1g 2g AND 3 - DOCKET NOS. 50-259',260'ND 296 - FACILITY OPERATING LICENSE DPR-33q 52'ND'8 - LICENSEE EVENT REPORT 50-260/95004'he enclosed report provides. details concerning a reactor scram on March 30, 1995, that resulted.from personnel error during, the performance of a surveillance instruction.

The reactor scram subsequently resulted in actuating the engineered safety feature system due to a sensed low reactor water level condition.

This report is submitted in accordance with 10 CFR 50.73 (a)(2)(iv) as a condition that resulted in the automatic actuation of any engineered safety feature.

Sincerely, Y

R.

D. Machon Si'te Vice President Enclosure cc:

See page 2

9'505020308 950428 PDR ADQCK 05000260 8

PDR

Il Cl it U

U.S. Nuclear Regulatory Commission Page

.2 April 28, 1995 Enclosure cc (Enclosure):

INPO Records Center 700 Gall'eria Parkway Atlanta, Georgia 30339 Paul Krippner American Nuclear Insurers Town Center, Suite 300S 29 South Main 'Street West Hartford, Connecticut 06107 NRC Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611 Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr,. J.

F. Williams, Project Manager U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 E. V. Imbro, NRR/RSIB U. S. Nuclear Regulatory Commission One White Flint, North 11555 Rockvi;lie Pike Rockville, Maryland 20852 E. J.

Leeds,.

NRR/DRPW U. S. Nuclear Regulatory Commission One White Flint,. North 11555 Rockville Pike Rockville, Maryland 20852