ML18038B111

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to LER 94-013 Re Unit 2 Scram That Occurred as Result of Failure Due to Setpoint Drift in Stator Cooling Water Temp Switch.Rev Reflects Addl Actions Being Taken to Evaluate Other Balance of Plant Devices
Date released: 09/27/2018 Download: ML18038B111


LER 94-013-01:on 941202,Unit 2 Received Full Automatic Scram from 54% Reactor Power.Caused by Mechanical Degradation of Stator Cooling Water Temp Switch.Affected Systems Restored to Operable Status & Temp Switch Replaced Before Restart
ML18038B112
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 01/19/1995
From: Austin S
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18038B112 (12)
Forwards Rev 1 to LER 94-013 Re Unit 2 Scram That Occurred as Result of Failure Due to Setpoint Drift in Stator Cooling Water Temp Switch.Rev Reflects Addl Actions Being Taken to Evaluate Other Balance of Plant Devices
ML18038B110
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 01/19/1995
From: Machon R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18038B110 (8)