I Hr. Oliver D. Kingsley, Jr, President, TVA Nuclear and Chief Nuclear Officer Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 October 17'1994

SUBJECT:

BROWNS FERRY NUCLEAR PLANT UNIT 2 SAFETY EVALUATION OF RELIEF REQUEST SPT-7 (TAC,NO. H89849)

Dear Mr. Kingsley:

14 By letter dated July 8, 1994, the Tennessee Valley Authority (TVA) requested relief from certain requirements of the 1986 Edition of the American Society of Mechanical Engineers (ASHE) Boiler and Pressure Vessel Code for the Browns Ferry Nuclear Plant (BFN) Unit 2.

The 1986 Code requires that all bolting be removed and inspected if leakage is observed at a bolted connection.

For valve 2-FCV-68-33, TVA seeks to apply the 1992 ASHE Code, which permits

.removal of a single bolt closest to the leakage area.

This valve had been the subject of an earlier one-time relief request from TVA, dated Hay 16,

1993, which was accepted by the NRC staff on Hay 21, 1993.

As documented in the enclosed safety evaluation, the staff finds that the proposed alternative inspection provides an acceptable level of quality and safety.

The NRC, staff has determined that the proposed alter native is therefore authorized, pursuant to 10 CFR 50.55a(a)(3),(i).

Please contact me at (301) 504-1470 if you have any questions regarding this topic.

Sincerely, Orsgsnal sighed by Docket No. 50-260

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DOCUMENT NAME:

G:iRR6833.LTR Frederick J.

Hebdon, Director Project Directorate II-4 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation To receive a copy of this docunent, indicate in the bax=

aC" = Copy with t attachment/enclosure

>>Ee ~ Copy Nith attachment/enclosure "N" -"No co y OFFICE PDII-4/

PD I I-4/PM OGC PDI I-4/D C

NAME BCla JWI Iliams FNebdon

~

DATE 09/

/94

~94 LO39 4/94 09/

/94 OFF ICIALIRECORD COPY 9410250093 941017 Q PDR ADOCK 05000260 P.,

.PDg'4003.9'NBC FKE IIlFÃKiIIlGFV~)i

'I

(,

V f

t J

l

~

~

~

~

Mr. Oliver D. Kingsley, Jr.

Tennessee Valley Authority CC:

Mr. Craven Crowell, Chairman Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxville, TN 37902 Mr.

W. H. Kennoy, Director Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Johnny H. Hayes, Director Tennessee Valley Authority ET 12A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. 0. J. Zeringue, Sr. Vice President Nuclear Operations Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Dr. Mark 0. Medford, Vice President Engineering 5 Technical Services Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. D.

E. Nunn, Vice President New Plant Completion Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. R.

D. Machon, Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.O.

Box 2000

Decatur, AL 35602 General Counsel Tennessee Valley Authority ET 11H 400 West Summit Hill Drive Knoxville, TN 37902 BROWNS FERRY NUCLEAR PLANT Mr. Roger W. Huston, Manager Nuclear Licensing and Regulatory Affairs Tennessee Valley Authority 4G Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. T.

D. Shriver Nuclear Assurance and Licensing Browns Ferry Nuclear Plant Tennessee Valley Authority P.O.

Box 2000

Decatur, AL 35602 Mr. Pedro Salas Site Licensing Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O.

Box 2000

Decatur, AL 35602 TVA Representative Tennessee Valley Authority 11921 Rockville Pike, Suite 402 Rockville, MD 20852 Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW., Suite 2900
Atlanta, GA 30323 Mr. Leonard D. Wert Senior Resident Inspector Browns Ferry Nuclear Plant U.S. Nuclear Regulatory Commission 10833 Shaw Road
Athens, AL 35611 Chairman Limestone County Commission 310 West Washington Street
Athens, AL 35611 State Health Officer Alabama Department of Public Health 434 Monroe Street

, Montgomery, AL 36130-1701

~t

-Docket F.i-le.

PUBLIC M. Russell/F. Miraglia R.

Zimmerman R. Spessard J.

Lieberman S. Varga 0-14-E-4 G. Lainas OGC 0-15-B-18 E. Jordan G. Hill (2 cys for each Docket No.) T-5-C-3 ACRS (10)

OPA OC/LFDCB G. Tracy 0-17-G-21 B. Boger RII T. McLellan