DOCKET 05000259 05000296

SUBJECT:

Application for amends to Licenses DPR-33

& DPR-68, consisting of TVA-BFN-TS-326 re ADS valves required to be operable prior to startup s revise ADS limiting conditions for operation w/inoperable valves.

acczr,za.~rzo Drs a.mVnOw DZvrowS Xrrax SvSrzrvr REGULATO INFORMATION DISTRIBUTION TEM (RIDS)

/

ACCESSION NBR:9210060469 DOC.DATE: 92/09/28 NOTARIZED: YES FACIL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee AUTH.NAME AUTHOR AFFILIATION ZERINGUE,O.J.

Tennessee Valley Authority RECXP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

DISTRIBUTION CODE:

A001D COPIES RECEXVED:LTR ENCL SIZE:

TITLE: OR Submittal: General Distribution 3 +/7 NOTES:

RECIPIENT ID CODE/NAME SANDERSgM.

'OSST.

COPIES LTTR ENCL 1

1 2

2 RECIPXENT ID CODE/NAME HEBDONiF WILLIAMSgJ.

COPIES LTTR ENCL 1

1 2

2 INTERNAL: ACRS NRR/DOEA/OTSB11 NRR/DST/SICB8H7 NUDOCS-ABSTRACT OGC/HDS3 RES/DS1R/EXB EXTERNAL: NRC PDR 6

6 1

1 1

1 1

1 1

0 1

1 1

1 NRR/DET/ESGB NRR/DST/SELB 7E NRR/DST/SRXB 8E OC L B

REG F

01 NSIC 1

1 1

1 1

1 1

0 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM PI-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 22

~

~

Tennessee Valley Authority, Post Office Box 2000, Decatur,'Alabama 35609 O. J. 'Ike.'eringue Vice President. Browns Ferry Operations SV 88 l992 TVA-BFN-TS-326 10 CFR 50.90 U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket Nos.

50-259 50-296 BROWNS FERRY NUCLEAR PLANT (BFN)

TVA BFN TECHNICAL SPECIFICATION (TS)

NO.

326 NUMBER OF AUTOMATIC DEPRESSURIZATION SYSTEM (ADS)

VALVES REQUIRED OPERABLE UNITS 1 AND 3 In accordance with the provisions of 10 CFR 50.4 and 50.90, we are submitting a request for an amendment (TS-321) to licenses DPR-33 and DPR-68 to change the BFN TS for Units 1

and 3 (Enclosure 1).

The proposed change for Units 1 and 3 will revise the number of ADS valves required to be operable prior to startup, revise the ADS limiting conditions for operation with inoperable valves, and revise the ADS bases.

These proposed changes for Units 1 and 3 are the same as those implemented on BFN Unit 2 prior to restart of Unit 2.

These previously approved changes were granted as Amendment 185 on Unit 2, dated January 9,

1991, based on a TVA submittal (TS-281) dated July 6, 1990.

92100b04b9 920928 PDR ADOCK 05000259 P

PDR

.)

U.S. Nuclear Regulatory Commission SEP 88 1992 A description and justification in support of the proposed change is provided as Enclosure 2.

A proposed determination of no significant hazards is provided in Enclosure 3.

We request that these specifications be made effective 30 days after issuance.

If there are any questions, please telephone G.

D. Pierce, Interim Site Licensing Manager, at (205) 729-7566.

Sincerely, Encosure cc:

See page 3

Subscribed and swor to before me on this Q+ day of 1992.

Notary Public My Commission Expires

$0- $0-

gy h I ~

gt C'-

P S,

U.S. Nuclear Regulatory Commission

~~~ ~8 1992 Enclosures cc (Enclosures):

American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford, Connecticut 06107-2445 Mr. Johnny Black, Chairman Limestone County Commission 310 Washington Street

Athens, Alabama 35611 Dr.

C.

E.

Fox State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36194 Mr. J.

E. Jones General Electric Company 735 Broad Street Suite 1108 James Building Chattanooga, Tennessee 37402 NRC Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611 Mr. Thierry M. Ross, Project Manager U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Mr. B. A. Wilson, Project Chief U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323