'CCELERATED DISTRIBUTION DEMONSTION SYSTEM "44 Y'EGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9204130101 DOC.DATE: 92/04/06 NOTARIZED: YES FACXL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee AUTH.NAME AUTHOR AFFILIATION ZERINGUE,O.J.
Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
DOCKET 05000259 05000296
SUBJECT:
Request for amend TS-308 to licenses DPR-33
& DPR-68 to change units 1
3 TS re trip setpoint for ADS timer, adding requirements for high drywell pressure bypass timer.
DISTRIBUTION CODE:
A046D COPIES RECEIVED:LTR!
ENCLj SIZE:
6 R'ITLE:
OR Submittal:
TMI Action Plan Rgmt NUREG-0737
& NUREG-0660 NOTES D
~
8 RECIPIENT ID CODE/NAME SANDERS,M.
ROSS,T.
INTERNAL: ACRS NRR/DST 8E2 OC/LF E~.
RES DSR DEPY EXTERNAL: NRC PDR COPIES LTTR ENCL 1
0 2
2 6
6 1
0 1
0 1
1 1
1 1
1 RECIPIENT ID CODE/NAME HEBDON,F WILLIAMS,J.
NRR/DREP/PEPB9 D NUDOCS-ABSTRACT OGC/HDS3 RES/DSIR/EIB NSXC COPIES LTTR ENCL 1
1 2
2 1
1 1
1 1
0 1
1 1
1 A
D D
D NOTE TO ALL"RIDS" RECIPIENTS' D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM PI-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISPS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 22 ENCL 18
0
/l
Tennessee Valley Authority, Post Office Box 2000. Decatur.'Alabama 35609 O. J. 'Ike'eringue Vice President, Browns Ferry Operations APR 0 6 1992 TVA-BFN-TS-308 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D.C.
20555 Gentlemen:
In the Matter of Tennessee Valley Authority Docket Nos.
50-259 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) TVA BFN TECHNICAL SPECIFICATION (TS)
NO. 308 AUTOMATIC DEPRESSURIZATION SYSTEM (ADS) TIMER In accordance with the provisions of 10 CFR 50.4 and 50.90, we are submitting a request for an amendment (TS-308) to licenses DPR-33 and DPR-68 to change the BFN TSs for Units 1 and 3 (Enclosure 1).
This proposed amendment for Units 1 and 3 changes the trip setpoint for the existing ADS timer and adds requirements for a high drywell pressure bypass timer.
These provisions meets the requirements of NUREG 0737, Item II.K.3.18.
These changes are required prior to restart of each affected BFN unit.
The changes for Units 1 and 3 are the same as those implemented on BFN Unit 2 prior to restart of that unit.
The Unit 2 TS change was approved as Amendments 162, dated January 30,
- 1989, and Amendment 185, dated January 9, 1991.
These amendments were based on TVA submittals dated July 29,
- 1988, and July 6, 1990.
A description and justification in support of the proposed changes is provided as Enclosure 2.
A proposed determination of no significant hazards is provided in Enclosure 3.
We request that these specifications be made effective 30 days after issuance.
.7 GO~r r~W
'sf204130101
'st20406 1
PDR ADOCK OS0002S9 P
$094 t(g
U.S. Nuclear Regulatory Commission APR 0 6 1992 If there are any questions, please telephone R. R. Baron, at (205) 729-7566.
Sincerely,
- 0. J. Zeringue Enclosure cc:
See page 3
Subscribed and sworn to before me on this &id day of~1992.
Not;ary-Publi
-'y Coimission Expires
-/"P~
gpf",'
k~
ll 7
4)
U.S. Nuclear Regulatory Commission Enclosure cc (Enclosure):
American Nuclear Insurers ATTN:
Librarian The Exchange, Suite 245 270 Farmington Avenue Farmington, Connecticut 06032 Mr. Johnny Black, Chairman Limestone County Commission 310 Washington Street
- Athens, Alabama 35611 Dr. C. E. Fox State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36194 Mr. J.
E. Jones General Electric Company 735 Broad Street Suite 1108 James Building Chattanooga, Tennessee 37402 NRC Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637
- Athens, Alabama 35611 Mr. Thierry M. Ross, Project Manager U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Mr. B. A. Wilson, Project Chief U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323
ENCLOSURE 1
PROPOSED TECHNXCAL SPECXFXCATXON CHANGE BROWNS FERRY NUCLEAR PLANT (TVA BFN TS-308)