UTION DEMON TION SY~M REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9001290041 DOC.DATE: 90/01/22 NOTARIZED: NO FACIL:50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee AUTH.NAME AUTHOR AFFILIATION RAY,M.L.
Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Submits info requested re control rod drive housing lateral restraint design bases.
DISTRIBUTION CODE:
D030D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: TVA Facilities Routine Correspondence NOTES:1 Copy each to: S.Black,D.M.Crutchfield,B.D.Liaw, R.Pierson,B.Wilson DOCKET I 05000260 05000260 RECIPIENT ID CODE/NAME LA GEARS,G COPIES LTTR ENCL 1
1 1
1 RECIPIENT ID CODE/NAME PD COPIES LTTR ENCL 1
1 INTERNAL: ACRS Xg~
REG FIL EXTERNAL: LPDR NSIC NOTES:
01 1
1 1
0 1
1 1
1 1
1 5
5 NUDOCS-ABSTRACT
,OGC/HDS2 NRC PDR 1'
1 0
1 1
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASIEI CONTACT THE.DOCUMENT CONTROL DESK, ROOM PI-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDt TOTAL NUMBER OF COPIES REQUIRED:
LTTR 16 ENCL 14
l
(
(.
t
~
t C
,I I V I
8 yl
~ ~
r TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 5N 1578 Lookout Place IJAN 22 1990 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Hashington, D.C.
20555 Gentlemen:
In the Matter of Tennessee Valley Authority Docket No. 50-260 BRONNS FERRY NUCLEAR PLANT -(BFN) UNIT 2 CONTROL ROD DRIVE (CRD)
HOUSING LATERAL RESTRAINT DESIGN BASES During the recent NRC audit of the engi neering design for the BFN Unit 2 CRD housing lateral restraints, TVA took the following actions:
1)
A summary list of the design criteria applicable to the different areas of restraint beam design will be submitted to the staff, thereby formally documenting the basis for this CRD lateral restraint design.
2)
General Electric design specification (D-Spec) 257HA346 was used as the source 'of the maximum CRD housing flange temperature in TVA's thermal evaluation.
NRC asked that GE/TVA compile a list of plant applicability for this D-Spec, to serve as evidence of prior NRC review and/or acceptance.
The purpose of this letter is to submit the requested information, thereby completing the actions agreed upon by TVA.
Enclosure 1 defines the criteria utilized for the design and installation of the CRD housing lateral restraints.
It is noted that these design criteria are consistent with the BFN licensing bases as defined within the Final Safety Analysis Report (FSAR) or with subsequent submittals from TVA to NRC.
Enclosure 2 documents the project applicability for General Electric design specification 257HA346.
Please refer any questions regarding this submittal for Patrick P. Carier, Manager of Site Licensing, (205) 729-3570.
Very truly yours, TENNESSEE VALLEY AUTHORITY Enclosures cc:
gee page 2
9001290041 900122 PDR ADOCK 05000260 P
PDC Manage
, Nuclear i ensing and Regulatory Affairs An Equal Opportunity Employer
~ 1 4
3 li 4
U.S. Nuclear Regulatory Commission cc (Enclosures):
Ms.
S.
C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Mr. B. A. Wilson, Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 NRC Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637
- Athens, Alabama 35609-2000
I o
ENCLOSURE 1
RESTRAINT BEAM DESIGN CRITERIA 1)
TVA Design Criteria BFN-50-C-7100, Revision 1, Design of Civil Structures, Attachment G, Detailed, Design Criteria for Miscellaneous Steel Components for Class I and II Structures.
2)
American Institute of Steel Construction (AISC) Specification for the
- Design, Fabrication and Erection of Structural Steel for Buildings, 6th
- Edition, 3)
Control Rod Drive Housing (CRDH) Lateral Restraint Clamps and Beams Legend or Description of Groups, Design Specification, Browns Ferry 2, 23A6371.,
Rev. 0, Nov.,
1989.
4)
TVA Design Criteria BFN-50-C-7102, Rev.
2, Seismic Design.
5)
TVA Std.
DS -C-1.7.1, Revision 4 General Anchorage to Concrete.
RESTRAINT CLAMP CRITERIA 1)
ASME Code Section III 1965 Edition VENTILATION DUCT DESIGN CRITERIA 1)
TVA Design Criteria BFN-50-7064B, Revision 1, Reactor Building Ventilation System Unit 2 2)
TVA Design Criteria BFN-50-C-7104, Revision 2, Design of Supports, Section 3
3)
TVA Std.
DS -C-1.7.1, Revision 4 General Anchorage to Concrete 0381k/4
Bid 19/1998 9
SITE LICENSING BFN ZNct.osvkt, tlirt IYuch ar Energy t285 '729 3111 P
~ C3 BPZ gg 1227 2i31 Date:
December 17, 1989 To:
Jim Rochelle Principal Civil Engineer Tennessee Valley Author:Lty 8.AJ.'rom:
B. H.
Ko p e, Engineer Reactor Component Design General Electric Nuclear Energy
Subject:
Project Application For Design Specification 257E3346 General Electric design specif:Lcation 257HA346 was used as the source for the 250 degree Fahrenheit control rod drive housing flange temperature used the evaluation of the Browns Ferry 2
control rod drive housing lateral restraint structure.
25"iHA346 defines the design requirements which are applicable to thai 919D260 control rod drive hous:ing.
This letter documents t.he domestic nuclear power plants;in addition to Browns Fe:."ry K'nits 1,
2, and 3 which use the 919D260 model Control Rod Dr:Lve Housing.
Brunswick 1 and 2
Cooper Duane Arnold Enrico Fermi 2
Fit2'patrick Hatch 1 and 2
Hope Creek 1
Limerick 1 and 2
Monticello Peach Bottom 2 and 3
Pilgrim Shoreham Susquehanna 1 and 2
Vermont Yankee ILt 7'-c',Fr5 APPl4YAL'erified by:
Z.
Xoakem, Senior Engineer Reactor Component Design Reviewed by:
G. A. Deaver, Manager Reactor Component Design
," ym7 -a~r: 7-it-7~~<~4 7A'Sg: &08'9
)
~