Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Deleting Redundant Testing for ECCS & RCIC Sys During Limiting Condition for Operation.Test Requirements Will Be Served by ASME Tests & Monthly Valve Alignments.Fee Paid
ML18033A515
Person / Time
Site: Browns Ferry  
Issue date: 01/13/1989
From: Michael Ray
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML18033A516 List:
References
NUDOCS 8901190412
Download: ML18033A515 (8)


Text

REGULATORY INFORMATION DISTRIBUTXON SYSTEM (RIDS)

D v&6 s

05000259 05000260 05000296 D

ACCESSION NBR:8901190412 DOC.DATE: 89/01/13 NOTARIZED: YES DOCKET FACIL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 05000259 50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260

'50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILIATION g~

~~~/

RAY,M.J.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to Licenses DPR-33,DPR-52

& DPR-68

'eleting redundant tes ing for ECCS 6 RCXC sys.

DISTRIBUTION CODE:

D030D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: TVA Facilities Routine Correspondence NOTES:1 Copy each to: F.McCoy,J.G.Partlow, S.Richardson,S.Black, B.D.Llaw.

1 Copy each to: S.Black, J.G.Partlow, S.Richardson B.D.Liaw,F.McCoy.

1 Copy each to: S. Black, J.G.Partlow,S.Richardson B.D.Lz.aw,F.McCoy.

RECIPIENT.

ID CODE/NAME SIMMS,M GEARS,G INTERNAL: ACRS NU OCS-BSTRACT R

G ILE 01 EXTERNAL: LPDR NSIC NOTES'OPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 5

5 RECIPXENT ID CODE/NAME PD ADM/LFMB OGC/HDS2 NRC PDR COPIES LTTR ENCL 1

1 1

0 1

0 1

1 R

I S

h NOTE 'IO ALL "RXDS" RECIPIENIS:

PIZASE HELP US K) REDUCE WASTE CONIACI IHE DOCX3NEPZ Q3ÃZROL DESK F ROOM Pl-37 (EXT. 20079) K) ELDIZKQE YOUR NAME FMH DIST':BUTION LIPIS FOR DOCUMENI'S YOU DGNIT NEEDf S

TOTAL NUMBER OF COPXES REQUIRED:

LTTR 16 ENCL 14

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 5N 157B Lookout Place GAIN 18 '$89 UPS.

Nuclear Regulatory Commission ATTN:

Document Control Desk Hashington, D.C.

20555 Gentlemen:

In the Hatter of Tennessee Valley Authority Docket Nos.

50-259 50-260 50-296 BRONNS FERRY NUCLEAR PLANT (BFN). UNITS 1, 2, AND 3 TVA BFN TECHNICAL SPECIFICATION NO.

256 DELETE REDUNDANT TESTING FOR EMERGENCY CORE COOLING SYSTEM (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCIC),SYSTEM (3.5/4.5)

In accordance with the provisions of 10 CFR 50.4 and 50.90, we are submitting a request for an amendment to licenses DPR-33, DPR-52, and DPR-68 to change the BFN Technical Specifications for units 1, 2, and 3 (enclosure 1).

The proposed change modifies BFN Technical Specifications to delete additional surveillance testing of redundant yet operable ECCS and RCIC Systems (3.5/4.5) during a limiting condition for operation.

The intended function of the existing testing requirements will be served instead by performance of periodic American Society of Mechanical Engineers,Section XI tests coupled by monthly valve alignment checks.

The description, reason for change, and justification in support of the proposed amendment is enclosed (enclosure 2).

A proposed determination of no significant hazards consideration is provided in enclosure 3.

890ii904i2 050002'39

g90iis, pod gDOCK pDC P

An Equal Opportunity Employer

s

U.S. Nuclear Regulatory Commission Enclosed is a check for the

$ 150 amendment fee required by 10 CFR Part 170.12.

He request this amendment be made effective 60 days after issuance.

Subscribed and sworn to before me on this lD day ofM~ 1989.

Very truly yours, TENNESSEE VALLEY AUTHORITY M. J.

Ray, Acting Manager Technical Services Licensing N tary Public My Commission Expires Enclosures cc:

See page 3

~

k U.S. Nuclear Regulatory Commission cc (Enclosures):

Ms.

S.

C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockvi'lie Pike Rockvi lie, Maryland 20852 Mr.. Charles R. Christopher

Chairman, Limestone County Commission P.O.

Box 188

Athens, Alabama 35611 Dr. C.

E.

Fox State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36104 Mr. J.

E. Jones General Electric Company,.

No.

1 Union Square 808 Krystal Building Chattanooga, Tennessee 37402 Mr. F.

R.

McCoy, Assistant Director for Inspection Programs TVA Projects'-Division U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611 American Nuclear Insurers Attention:

Librarian The Exchange, Suite 245 270 Farmington Avenue Farmington, Connecticut 06032

e