Text

ACCEL'HMTED DJ IBUTION DEMONSTR ON SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

'ACCESSION NBR:8806170012 DOC.DATE: 88/06/13 NOTARIZED: YES DOCKET FACIL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 05000259 50-260 Browns Ferry Nuclear Power Station, Unit. 2, Tennessee 05000260 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILIATION GRIDLEY,R.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to Licenses DPR-33,DPR-52

& DPR-68, consisting of Tech Spec 243 re HPCI 6 RCIC instrumentation.

DISTRIBUTION CODE:

ADOID COPIES RECEIVED: LTR l ENCL I SIZE: S~

TITLE: OR Submittal:

General Distribution NOTES:G.Zech 3 'cy.

1 cy.'a. to: Ebneter,Axelrad,"S.Richardson B.D.Liaw,K.Barr, OI.

G.Zech 3 cy.

1 cy.

ea to: Ebneter,Axelrad,S.Richardson, B.D.Liaw,K.Barr, OI; G.Zech 3 cy.

1 cy.

ea to: Ebneter,Axelrad,S.Richardson, B. D. Liaw,K.Barr,

. OI.

05000259 05000260 j 05000296 g RECIPIENT ID CODE/NAME JAMERSON,C MORAN,D'NTERNAL:

ACRS'RR/DEST/ADS 7E NRR/DEST/ESB 8D NRR/DEST/RSB 8E NRR/PMAS/ILRB12 OGC 15-B-18 RES/DE/EIB EXTERNAL: LPDR NSIC NOTES COPIES LTTR ENCL 1

0 1

1 6

6 1

1 1

1 1

1 1

1 1

0 1

1 1

1 1

1

'9 9

RECIPIENT ID CODE/NAME PD GEARS,G ARM/DAF/LFMB NRR/DEST/CEB 8H NRR/DEST/MTB 9H NRR/DOEA/TSB 11 NUDOCS-ABSTRACT G

01 NRC PDR COPIES LTTR ENCL 5

.5 1

1 1

'0 1

1 1

1 1

1 1

1 1

1 1

1 W ~c P/ro 8 $97do D

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 38 ENCL 35.

I

~

~

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 3740'I 5N 157B Lookout Place

'dUII13 mac U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket Nos

~ 50-259 50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) UNITS 1, 2, AND 3 TVA BFN TECHNICAL SPECIFICATION NO. 243 ADD IIPCI AND RCIC INSTRUMENTATION TO TABLE 3.2.B/4.2.B TAC NO. 00101,

00102, and 00103 In accordance with the provisions of 10 CFR 50.4 and 50.90, we are submitting a request for amendment to licenses DPR-33, DPR-52, and DPR-68 to change the BFN Technical Specifications for units 1, 2, and 3 (enclosure 1).

The proposed change addresses updating tables 3.2.B and 4.2.B by adding the instrumentation used to trip and isolate the High Pressure Coolant Injection and the Reactor Core Isolation Cooling Systems on either low steam supply pressure or high turbine exhaust pressure.

Description, reason for change, and justification in support of the proposed changes are enclosed (enclosure 2).

A proposed determination of no significant hazards consideration is provided in enclosure 3.

8806170012 880613 PDR ADOCK 05000259 P

DCD An Equal Opportunity Employer (geo <'II

~ $3yoe tI.go/

I p'0

U.S. Nuclear Regulatory Commission I

Enclosed is a check for the

$ 150 amendmen't fee required by 10 CFR Part 170.12.

Ne request that these specifications be made effective 60 days after issuance because of the number of procedure revisions required.

Very truly yours, TENNESSEE VA EY AUTHORITY Subscribe) qi}d sworn to before me

>'on, his ~3~'day o 198&.

R.

ridley, D

ector Nuclear Licensing and Regulatory Affairs otary Public Hy Commission Expires Enclosures I

cc:

(Enclosures)

Hr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Harietta Street, NH, Suite 2900 Atlanta, Georgia 30323 Hs.

S.

C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One Nhite Flint, North 11555 Rockvi lie Pike Rockville, Haryland 30323 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611

1 l

'u h'l I.

TENNESSEE YALLEYAUTHORITY CHATTANOOGA. TENNESSEE 3740'I 5N 157B Lookout Place

'dUNl3 tggg U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Hashington, D.C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket Nos.

50-259 50-260 50-296 BRONNS FERRY NUCLEAR PLANT (BFN) UNITS 1, 2, AND 3 TVA BFN TECHNICAL SPECIFICATION NO. 243 - ADD HPCI AND RCIC INSTRUMENTATION TO TABLE 3.2.B/4.2.B

- TAC NO. 00101,

00102, and 00103 In accordance with the.provisions of 10 CFR 50.4 and 50.90, we are submitting a request for amendment to licenses DPR-33, DPR-52, and DPR-68 to change the BFN Technical Specifications for units 1, 2, and 3 (enclosure 1).

The proposed change addresses updating tables 3.2.B and 4.2.B by adding the instrumentation used to trip and isolate the High Pressure Coolant Injection and the Reactor Core Isolation Cooling Systems on either low steam supply pressure or high turbine exhaust pressure.

Description, reason for change, and justification in support of the proposed changes are enclosed (enclosure 2).

A proposed determination of no significant hazards consideration is provided in enclosure 3.

An%qual Opporgunity Employer

U.S. Nuclear Regulatory Commission Enclosed is a check for the

$ 150 amendment fee required by 10 CFR Part 170.12.

He request that these specifications be made effective 60 days after issuance because of the number of procedure revisions required.

Very truly yours, TENNESSEE, VA EY AUTHORITY

,( f.

Su'bscribeP gad sworn to before me

>on this ~3~ "day o 1988.

R.

ridley, D

ector Nuclear Licensing and Regulatory Affairs otary Public My Commission Expires Enclosures cc:

(Enclosures)

~

Mr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NN, Suite 2900 Atlanta, Georgia 30323 Ms.

S.

C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One Nhite Flint, North 11555 Rockville Pike Rockville, Maryland 30323 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637

Athens, Alabama 35611

ENCLOSURE 1

PROPOSED TECHNICAL SPECIFICATIONS REVISIONS BRONNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 (TVA BFN TS 243)