ML18033A237

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Changing Operability Requirements for Standby Gas Treatment & Control Room Emergency Ventilation Sys in Order to Proceed W/Fuel Insp & Reconstitution Program.Fee Paid
ML18033A237
Person / Time
Site: Browns Ferry  
Issue date: 06/01/1988
From: Gridley R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML18033A238 List:
References
TAC-R00348, TAC-R00349, TAC-R00350, TAC-R348, TAC-R349, TAC-R350, NUDOCS 8806070119
Download: ML18033A237 (6)


Text

(

I U'

ACCELERATED DISTRIBUTION DEMONS~ON REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8806070119 DOC.DATE: 88/06/01 NOTARIZED: YES DOCKET I FACIL:50-259 Browns Ferry Nuclear Power Station, Unit 1, Tennessee 05000259 50-260 Browns Ferry Nuclear Power Station, Unit 2, Tennessee 05000260 50-296 Browns Ferry Nuclear Power Station, Unit 3, Tennessee 05000296 AUTH.NAME AUTHOR AFFILIATION GRIDLEY,R.

Tennessee Valley Authority RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to Licenses DPR-33,DPR-52

& DPR-68, changing operability requirements for standby gas treatment.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR I ENCL i SIZE: +

TITLE: OR Submittal:

General Distribution l

R I

I D

NOTES".G.;Zech 3 'cy.

1 cy.

ea

'.D.Liaw,K.Barr, OI.

G.Zech 3 cy.

1 cy.

ea B.D.Liaw,K.Barr, OI.

G.Zech 3 cy.

1 cy.

ea B.D.Liaw,K.Barr, OI.

ito:

to:

Ebneter',Axe'lrad,S.Richardson Ebneter,Axelrad,S.Richardson, to: Ebneter,Axelrad,S.Richardson,

,05000259 8 05000260j 05000296A RECIPIENT ID CODE/NAME JAMERSON,C MORAN,D INTERNAL: ACRS NRR/DEST/ADS 7E NRR/DEST/ESB SD

,'NRR/DEST/RSB SE NRR/PMAS/ILRB12 OGC'15-.B-18 RES/DE/EIB EXTERNAL: LPDR NSIC NOTES:

COPIES LTTR ENCL 1

0 1

1 6

6 1

1 1

1 1

1 1

1 1

0 1

1 1'

1 1

1 9

9 NRC 'PDR 4

II RECIPIENT ID CODE/NAME PD GEARS,G ARM/DAF/LFMB NRR/DEST/CEB 8H NRR/DEST/MTB 9H NRR/DOEA/TSB 11 NUDOCS-ABSTRACT RE~i~i 01 COPIES LTTR ENCL 5

5 1

1 1

0 1

1 1

1 1

1 1

1 1

1 1

1, R

g OAeSP 4/5>

+ p5z6M

'A TOTAL NUMBER OF COPIES REQUIRED:

LTTR 38 ENCL 35

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 5N 157B Lookout Place TVA-BFN-TS-245-T

'JUN 0 i 1988 10 CFR 50.90 U.S.

Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Gentlemen:

In the Matter of Tennessee Valley Authority Docket Nos.. 50-259 50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) TVA BFN TECHNICAL SPECIFICATION NO. 245-T

.,Reference 1;

Letter from'VA to'RC dated March 23,

1988, "Browns Ferry Nuclear Plant (BFN) Fuel Inspection -and Reconstitution" 2.

Letter from TVA to NRC dated May 20,

1988, "Browns Ferry Nuclear Plant (BFN) Fuel Inspection and Reconstitution" In accordance with the provisions of 10 CFR 50.4 and 50,90, we are submitting a request for an amendment to licenses DPR-33, DPR-52, and DPR-68 to change the BFN Technical Specifications for units 1, 2, and 3 (enclosure 1).

Reference 1 provided NRC with a description of the BFN fuel inspection and reconstitution program which was updated by reference 2.

TVA requests temporary changes to the operability requirements for the Standby Gas Treatment System and Control Room Emergency Ventilation System.

Relaxation of these requirements will allow system modifications and maintenance needed for restart to proceed in parallel with the fuel inspection and reconstitution program.

This relaxation can be accomplished without reducing the margin of safety.

These temporary changes will be in effect until just before the start of'uel load.

The description, reason for change, and justification in support of the proposed temporary changes are enclosed (enclosure 2).

A proposed determination of no significant hazards consideration is provided (enclosure 3).

gee t 8806070ii9 38060i PDR ADOCK 05000259 p

DCD An Equal Opportunity Employer Jck~

'<<w, j)

I

U. S. Nuclear Regulatory Commission JUNO'geg We request your expedient review and approval of the enclosed temporary changes.

We request that these specifications be made effective upon receipt of these changes.

Enclosed is a check for $ 150 amendment fee required by 10 CFR Part 170.12.

Very truly yours, TENNESSEE VAL EY AUTHORITY

~

~

~

R. Gridley, D'rector Nuclear Licensing and Regulatory Affairs Subs'c'ribedynd sworn o before me ohi s ~ ~~day of 1988.

r Notary Public 1

My Commission Expires

'I Enclosures cc:

See page 3

~A I

y

/

I

U.S. Nuclear Regulatory Commission cc (Enclosures):

Mr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission-Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. G.

G. Zech, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Browns Ferry Resident Inspector Browns-Ferry Nuc'lear 'Plant

'Route 12, Box='637

Athens, Alabama 35611 Mr. Charles

'R. Christopher

Chairman, Limestone County Commission P.O.

Box 188

Athens, Alabama 35611 Dr.

C.

E.

Fox State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36104 Mr. J.

E. Jones General Electric Company No.

1 Union Square 808 Krystal Building Chattanooga, Tennessee 37402