REGULA

. Y INFORMATION DISTRIBUTI SYSTEM (RIDS)

ACCESSION NBR: 8803010434 DOC. DATE: 88/01/31 NOTARIZED:

NO DOCKET FACIL: 50-259 Browns Ferry Nuclear Power,Stations Unit ii Tennessee 05000259 50-260 Browns Ferry Nuclear Power Stationi Unit 2i Tennessee 05000260 50-296 Browns Ferry Nuclear Power Stationi Unit 3.

Tennessee 05000296 AUTH. NAME AUTHOR AFFILIATION Tennessee Valley Authority RECIP. NAME RECIPIENT AFFILIATION

SUBJECT:

Discharge monitoring rept for Jan 1988.

DISTRlBUTION CODE:

IE48D COPIES RECEIVED: LTR ~ ENCL J SIZE:

TITLE:

50. 36a(a) (2) Semiannual Effluent Release Reports NOTES: G. Zech 3 cg.

1 cg.

ea to: Ebneteri Axelradi S. Richardson B. D. Liawi K. Barri Donohewi OI.

G. Zech 3 cg.

1 cg.

ea to: Ebneter Axelradi S.

Richardson'.

D. Liawi K. Barri Donohewi OI.

G. Zech 3 cg.

1 cg.

ea to: Ebneteri Axelradi S. Richardsoni B. D. Liawi K. Barry Donohewi OI.

05000259 05000260 05000296 RECIPIENT ID CODE/NAME JAMERSONi C MORANr D INTERNAL: AEOD/DOA ARM TECH ADV NRR/DREP/RPB10A 01 R

DRSS/EPRPB COPIES LTTR ENCL 0

1 1

1 4

1 REC IP IENT ID CODE/NAME PD STANGi J AEOD/DSP/TPAB NRR/DEST/PSBSD1 NRR/PMAS/ ILRB12 RGN2 FILE 02 COPIES LTTR ENCL EXTERNAL: BNL TICHLERiJ03 NRC PDR LPDR NOTES:

1 10 TOTAL NUMBER OF COPIES REQUIRED'TTR M

ENCL 32

K I'

k l, I

I K IK 4

rJ K,,C,

NPDES I AL0022080 ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT DISCHARGE MONITORING.REPORT Tennessee Valley Authority BRONNS FERRY NUCLEAR PLANT DSN 101 Diffuser Discharge Structure NONTH J~anuar 1988 PARAM FLON pH 6.0 mb. River em erasure 24hr Av Max downstream 24hr Av Max p.S.. RjyyrO pownstyeam Temperature Hour l Max 24hr Av Max MAX UNITS MGD 9.0

90. 0 6 Hrl Rd 4 Rd s

>6

93. 0
10. 0 FREQ.

Cont'.

1 633. 6 1/wk Continuous

48. T Continuous
48. 9 purl 0

Continuous Continuous 0.5 2

633. 6 3

633. 6 4

633. 6 5

633. 6 6

633. 6 7

633. 6 8

633. 6 633. 6 10 633. 6 11 633. 6 12 633. 6 13 633. 6 14 633. 6 15 633. 6 16 633. 6 17 633. 6 18 633. 6 19 633. 6 20 633. 6 21 633 '

22 633. 6 23 633. 6 24 633. 6 25 633. 6 26 633. 6 27 633. 6 28 633. 6 29 633. 6 30 633. 6 31 633. 6 7.7

8. 1 7.9 7.6
48. 3
47. 3
46. 6
46. 0
44. 1
42. 7
40. 3
40. 2
39. T
39. 3
40. 0
41. 1
41. 1
39. 6
40. 3 41.4
42. 4
43. 9
47. 3
47. 3
46. 6
45. T
45. 6
45. 4
44. 6
42. 6
42. 2
43. 3
44. 5
45. 6
48. 8 4T. 5
46. 5
45. 8
44. 6
43. 8
41. 6
40. 5
40. 6
40. 1
38. 1
40. 1
40. 2
39. 2
39. 8
40. 2 41.5
43. 6 48.0
48. 0
46. 6
44. 5
44. 3
44. 5
44. 0
41. 9
42. 2
42. 6
43. 7 0

0 0

0 0

0 0

0 0

0 0

0 0

0

48. 4
46. 6
46. 3
45. 7
45. 0
43. 6
42. 4 41.6
40. 9
40. 5
40. 1
40. 7
40. 2 39'. 9
40. 1
41. 1 42 ~ 3
45. 4
48. 9
47. 7
45. 7 44, ~ 4
44. 5
44. 4
43. 3
41. 8
42. 9
43. 5 44
45. 5 0.7 0.1 0.5 1.3 1.7 0.3 1.3 0.9

-0. 9

-0. 3

-0. 2 0.0

-0. 2

-1. 0

-0. 6

-0. 1 0.7

0. T 0.0

-0. 5

-0. 3

-0. 5 0.3

-0. 5

-0. 2

-0. 5 No: IAX tw m

a. "G CllCI 633. 6 633. 6
8. 1
48. 7
43. 7 48.

9'3.4 49'. 5

43. 8 1.7 0.1 7.6 gg 1IN Bate:

gg I certify under penal t y of Iaw Chat thi s document and alI at tachments were

'prepared under the direction or supervision in accordance wi th a system

mt 0 F95 designed to assure that qualified personnel properl y gather and evaluate the g

linformation sabmi tted.

Based on my inquiry of Che person or persons who g+

'manage the system~ or those persons directly responsi ble for gathering the Iinformation, Che i nformation submitted is, to Che best of my knowledge and OIL m~ 'belief, true, accurate~

and complete.

I'm aware that there are signi ficant

+++Ipenalties for sabmi tti ng false information~ including the possibility of fine and imprisonment for knowing vi ola ions.

Signatare of Responsible 0fficial lI

(

r 1

S C ~

ALABAMA DEPARTMENT QF ENVIRONMENTAL ANAGEMENT DISCHARGE MONITORING REPORT Tenneeeee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 102 Sedimentation Pond MONTH J~anuar 1988 NPDES I AL0022080 PARAM UNITS FLOW MGD pH MIN. 6. 0 9.0 5a Ua m /I TSS.

100 m /1 COMMENTS FREQ.

1/RELEASE 1/RELEASE 1/RELEASE 2/RELEASE 10 12 13 15 16 17 18 20 21 22 24 26 28 30 31 AVG MIN TOTAL o Dischar e*

  • No Dischar e This Entire Ifonth I certify under penalty of Iaw that this document and all attachments were prepared under Che direction or supervision in accordance with a system designed to assure Chat quali fied personnel properly gather and evaluate the information submitted.

Based on my inquiry of the person or persons who manage Che system~

or those persons directly responsible for gathering the informati on~ the information submi Cted i s~ to the best of my knowledge and belief~ true~ accurate, and complete.

I am aware Chat there are signi ficant penalties for submi Cting false information, including the possi bility of fine and imprisonment for knowing vi olati ons.

Si gnat ur e of Responsible Official Date:

J. ~

  • I AkV I

~

~

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANASEMENT DIBCHARSE MONITORINS REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 103 Unit, 1,2,3 Turbine Station Bump MONTH

~Januar FLOW MAX 1988 15 20 TSS 30 100 NPDES ¹ AL0022080 COMMENTS UNITS FREQ.

MSD 1/WEEK m /1 1/WEEK m /l 1/WEEK 0.900000 5

10 13 15 16 17 0.600000 20 22 23 0.9'36000 17 25 27 28 0.527000 5

0. 9'36000 0.740750 5

23 13 I certi fy under penalty of Iaw that this document and all attachments were prepared under the direction or supervision in accordance with a systemic designed to assure that quali fied personnel properly gather and evaluate the information submitted.

Based on ey inquiry of the person or persons who manage the system~

or those persons di rectl y responsible for gathering the inforeati on~ the infornati on submitted i s~ to the best of ey knowledge and beli ef, true, accurate~

and complete.

I ae aware that there are significant penalties for subai tti ng false information, including the possibili ty of fine and icapri sonment for knowing violations Si gnat ure of Responsi bIe Official Bate:

r

~I, Y

t1t

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT DISCHARGE MONITORING REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 104 Liquid Radwaste MONTH J~anuar 1988 NPDES 0 AL0022080 PARAM FLOW Otic 6 "'S8 LDT/08cG LDT/TSS Copper Iron 15 20 30 100 15 20 30 100 1.0 1.0 UNITS MGD m /L m /L m /L m /L m /L m /L FREQ.

1/BATCH 1

No Di.

2 0.047950 3

0.018265 2/wk 2/wk 1/BATCH 1/BATCH 1/BATCH 1/BATCH 6

0.031061 5.

1 8

0. 030994 0.031284 10 0.021751 12
0. 0301 8

13 0.030216 14 0.031061 15 0.030421 16 0.018349 17 0.031061 18 0.025758 19 0.033069 20 0.054142 21 22 0.053882 23

0. 019095 24 0.060818 25 0.022880 26 0.031227 27 0.021752 28 0.031227 29'.022327 30
0. 019050 31 0.031284 5i 1

5 1

5-1 5

1 5

1 5

1 5

MAX 0.060818

'.031163 5

1 5

23 23 E certify under penalty of law that this document and all attachments were prepared under the di recti on or supervision in accordance with a system designed to assure that quali fied personnel properly gather and evaluate the information submitted.

Based on my inquiry of the person or persons who manage the system~ or those persons directl y responsi ble for gatheri ng the information~ the information submi tted is~ to the best of my knowledge and beli ef~ true~ accurate~

and complete.

E am aware that there are si gni ficant penalties for submitting false informati on~ including the possibility of fine and imprisonment for knowing violations.

Si gnat ure of Responsible Official Date:

~

4

4 4 4 4

~

4 4

4 4

~

I

~

)

3 ~

~

I 4

4KKK~

KRK~

%IRK~

KIRK

~5KR~

KI~

~B~

RR~

~l~

ER~

KR~

IRI~

IRI~

IRI~

m~

EKIBR~

KR~

IRI~

RK~

RK~

RR~

RK~

RK~

RR~

RR~

RR~

RR~

IK~

RK~

EH%

gppcg

~

I

~

R

~

~

4

~

4

~ ~

4 4

~ ~

~

~

4 ~

~ ~

g 8 ~ t t

f ~

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANASEMENT DISCHARSE MONITORINS REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 106 Condenser Cooling Water Station Sump MONT8 J~anuar 1988 NPDES 8 AL0022080 PARAM UNITS FREQ.

FLOW MSD 1/WEEK OSS 20 m /l 1/WEEK TSS 30 100 m /l 1/WEEK COMMENTS 7

No Dischar e

8 This Entire Week 12 13 No Dischar"e 1 5 This Entire Week 17 18 21 No Dischar e

22 This Entire 23 Week 27 28 No Disrhar e

29 This Entire 30 eek 31 MAX AVS No Dischar e*

  • DISCHARGE ROUTED TO SEDIMENTATION POND FOR ENTIRE REPORTING PERIOD.

E certify under penalty of law that this document and all attachments were prepared under the direction or supervision in accordance with a system designed to assure that quali fied personnel, properly gather and evaluate the information submitted.

Based on my inquiry of the person or persons who manage the system~

or those persons directl y responsible for gatheri ng the informati on~ the information submitted i s~ to the best of my knowledge and belief~ true~ accurate~

and complete.

E am aware that there are significant penalties for submitting false information, including the possibi lity of fine and imprisonment for knowi ng violations.

Signature of Responsible Official Bate:

r

~ I 1

l '

5

, J~

1

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT DISCHARGE MONITORING REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 107 Unit 3 Control Bldg.

Drain MONTH J~anuar 1988 NPDES I AL0022080 PARAM MAX UNITS FREQ.

FLOW MGD 1/WEEK 15 20 m /l 1/WEEK TSS 30 100 m /l 1/WEEK COMMENTS 0.001330 5

10 12 13 14 15 16 17 18 19 20 21 22 0.001200 0.000912 5

36 12 26 27 28 29 30 0.001900 5

0 Sc G RESAMPLE ( 5 MAX 0.001900 0.001336 12 I certify under penalty of law that this document and all attachments were prepared under the direction "or supervision in accordance wi th a system designed to assure that qualified personnel properl y gather and evaluate the information submitted.

Based on my inquiry of the person or persons who manage the system~

or those persons directly responsible for gathering the information~ the i nformati on submitted is~ to the best of my knowledge and belief~ true~ accurate~

and complete.

I am aware that there are significant penalties for submitting false i nformati on~ including the possi bi lity of fine and imprisonment for knowing violati ons.

- Si gnature of Responsi ble Official Bate:

e

~

lp n.

IL

~I 0 I

4

~

~

~

)

Rial

~RNR~

~R~~

RSKIR~

IRIRR~

~R~

Rl~

m~

~8~

RR~

KRHRR~

IRI~

IRI~

IRI~

m gggRR~

IRI~

IRI~

ml~

RR~

QgIRI~

SR~

gg gg

~i Qg RXX%

RK'R

~ ~

i ~ l

~

~

~

~ ~

~ w ~

~

~

~ r

c

')

4i 4>>I

I I g

~

ALABAMA D ARTMENT OF ENVIRONMENTAL M AGEMENT DISCHARGE MONITORING REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR. PLANT DSN 109 Diesel Bldg.

Sump Unit 3

MONTH J~anuar 1988 NPDES 0 AL0022080 PARAM AVG UNITS FREQ.

FLOW MGD 1/WEEK 08(G 20 m /1 1/WEEK TSS 30 100 m /1 1/WEEK COMMENTS 6

7 No Discharge 8 This Entire 9 Week 10 12 13 14.

No Discharge 15 This Entire 16 Week 17 18 20 21 No Discharge 22 This Entire 23 Week 25 27 28 No Dischar e

29 This-Entire-30 Week 31 MAX AVG No Dischar e *

  • No Discharge T xs hntxre. 1ont I certi fy under penalty of lax that this document and all attachments were prepared under the direction or supervision in accordance with a system designed to assure that quali fied personnel properly gather and evaluate Che information submitted.

Based on my inquiry of the person or persons wtho manage the system~ or Chose persons directly responsible for gathering Che information, the information submitted is, to the best of my knowledge and beli ef, true~ accurate, and complete.

I am aware Chat Chere are significant penalties for submitting false information, including Che possibility of fine and imprisonment for knowing violations.

Si gnature of Responsible Official Bate:

t II t

I Cf ~

I3 y

~

~

~

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT DISCHARGE MONITORING REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN 110 Unit 1

Sc 2 Ok%ice Bldg. Drain MONTH J~anuar 1988 NPDES 0 AL0022080 PARAM AVG MAX UNITS FREQ.

FLOW MGD 1/WEEK 15 20 m /l 1/WEEK TSS 30 100 m /l 1/WEEK 43 COMMENTS 37 0.000500 26 35 10 12 13 14 0.000254 22 14 TSS RESAMPLES 122 8c 34 16 44 18 22 20 21 22 23 25 26 27 28 29 30 MAX 0.000289 0.004830 0.004830 0'01468 13 13 32 104 39 134 347 183 30 66 378 70 TSS RESAMPLES 378 5 111 E certify ander penalty of law that thi s docament and all attachments were prepared ander the direction or supervision in accordance with a system designed to assure that qaali fied personnel properly gather and evaluate the information submitted.

Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information~ the information submitted is~ to the best of my knowledge and beli ef, trae,

accarate, and complete.

E am aware that there are significant penalties for sabmi tting false information~ including the possibility of fine and imprisonment for knowi ng violations.

Signature of Responsible Official Date:

ai LI

'hh

'f f4~

I

ALABAMA D RTMENT OF ENVIRONMENTAL M AGEMENT DISCHARGE MONITORING REPORT Tennessee Valley Authority BROWNS FERRY NUCLEAR PLANT DSN iii Sewage Treatment Lagoon MONTH J~anuar 1988 NPDES 5 AL0022080 PARAM MAX UNITS FREQ.

FLOW MGD 5/WEEK 0.031248 TSS 90 m /l 2/MONTH BOD5 30 m /l 2/MONTH COMMENTS 0.049248 0.049248 0.049248 0.039600 0.049248 22 10 12 13 15 0.031248 0.031248 0.031248 0.039600 0.039600 29 17 18 21 0.031248 0.039600 0.039600 0.039600 0.039600 19 21 26 27 28 29 0.039600 0.039600 0.039600

. 0; 049248 0.049248 20 31 AVG 0.049248 0.040368 29 21 22 E certi fy under penalty of Iaw Chat this document and all attachments were prepared under the direction or supervisi on in accordance wi th a system designed Co assure that quali fied personnel properly gather and evaluate Che information submi Cted.

Based on my inquiry of the person or persons who manage Che system~

or Chose persons directl y responsi ble for gatheri ng the information, the informati on submitted i s~

Co the best of my knowledge and beli ef, true, accurate, and complete.

I am aware Chat there are si gni ficant penalti es for submitting false informati on~ including the possi biIity of fine and imprisonment for knowi ng violati ons.

Signature of Responsi bIe Official Bate:

t

Descr'i tion of Dischar e

DSN 107 Unit 3 Control Building Drain The oil and grease content exceeded the daily maximum of 20 mg/1.

The oil and grease content of the discharge was 36 mg/1 on January 20, 1988.

Cause and Period of Noncom liance The cause of this noncompliance was not determined because communication of the occurrence was not prompt.

Two samples taken on January 25, 1988 contained 5 mg/1 oil and grease.

The maximum period of noncompliance was thirteen days.

Ste s Taken to Reduce Eliminate and Prevent Recurrence of Noncom 1 in

~Dischar e

Laboratory personnel were reminded of the need to immediately notify the Environmental Engineering Section of all noncompliances to allow investigations of their cause.

In addition, procedure revisions are being made to require prompt data review by the laboratory shift supervisor and to specify the permit limit on the data sheet.

I4 F

Oescr'i "tion of Oischar e

DSN 110 Unit 1

8 2 Office Building Drain The total suspended solids (TSS) content exceeded the daily maximum of 100 mg/1 and the daily average of 30 mg/1.

The table below contains the dates and values of the noncompliances.

Cause and Period of Noncom liance One possible cause was iron oxide laden

,water drained from the hot water generator'n the control bay chiller room to the floor drain.

This was discussed in the. December OMR.

This system was drained in December so a maintenance request could be performed on a hot water recirculation pump.

Two flushes of this line were done on January 11 and January 24-25, 1988.

Another possible cause was identified as a sink in'the control bay used to wash cooking and eating utensils.

Food, soap, and grease from this sink may be resulting in the high and fluctuating total suspended solids content.

The following table lists the maximum periods of noncompliance.

DATE January ll January 21 January 24-25 January 27 VALUE 122 104 MAXIMUM PERIOD OF NONCOMPLIANCE 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, 15 minutes (Flush) 2 days, 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, 42 minutes 183 1 day, 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br />, 25 minutes

134, 347,
378, 111

, 2 days, 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, 42 minutes (Flush)

Ste s Taken to Reduce Eliminate and Prevent Recurrence of Noncom 1 in Oischa~cie We are investigating ways to route the sink drain to the sanitary wastewater system.

If this cannot be done, the sink will be removed from service.

0919m