OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION January 29, 2018 Mr. B. Joel Burch Vice President and General Manager BWXT Nuclear Operations Group, Inc.

P. O. Box 785 Lynchburg, VA 24505-0785

SUBJECT:

BWXT NUCLEAR OPERATIONS GROUP - NUCLEAR REGULATORY COMMISSION SECURITY INSPECTION REPORT 70-27/2017-005

Dear Mr. Burch:

This letter refers to an inspection conducted from October 1 through December 31, 2017, at the BWXT Nuclear Operations Group, Inc. (NOG) facility in Lynchburg, VA. The purpose of this inspection was to determine whether activities authorized under the license were conducted safely and in accordance with U.S. Nuclear Regulatory Commission (NRC) requirements. The enclosed report presents the results of this inspection.

The inspection examined activities conducted under the license as they relate to the common defense and security, and to confirm compliance with the Commissions rules and regulations, and with the conditions of the license. Areas examined during the inspection are identified in the enclosed report. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations of activities, and interviews with personnel.

There were no violations of more than minor significance identified during the inspection.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding, of the NRC's "Agency Rules of Practice and Procedure," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

The enclosure contains Sensitive Unclassified Non Safeguards Information (Security-Related Information). Upon separation, this cover letter is DECONTROLLED.

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION B. Burch 2

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION However, the material enclosed herewith contains Security-Related Information in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's Agencywide Documents Access and Management System (ADAMS).

If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.

Sincerely,

/RA/

Eric C. Michel, Chief Projects Branch 2 Division of Fuel Facility Inspection Docket No. 70-27 License No. SNM-42

Enclosure:

NRC Inspection Report No. 70-27/2017-005 w/

Attachment:

Supplemental Information cc:

Christopher T. Terry, Manager Licensing and Safety Analysis BWXT Nuclear Operations Group, Inc.

P.O. Box 785 Lynchburg, VA 24505-0785 Steve Harrison, Director Division of Radiological Health Department of Health 109 Governor Street, Room 730 Richmond, VA 23219

ML18031A367 SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DFFI SIGNATURE

/RA/

NAME EMichel DATE 1/29/2018 1/ /2018 1/ /2018 1/ /2018 1/ /2018 1/ /2018 1/ /2018 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO