Docket ttfo. 60-38 /388 APPLICANT:

Pennsylvania Power and Light Company FACILITY:

Susquehanna Steam Electric Station, Units 1 and 2

SUBJECT:

SUMtNRY OF MEETING HELD ON DECEMBER 12, 1979 TO DISCUSS ASME CODE STRESS ANALYSIS OF A SAMPLE PIPING SYSTEM FOR THE PENNSYLVANIA POWER AND LIGHT COMPANY - SUSQUEHANNA PLANT On December 12, 1979, a meeting was held at the Susquehanna site to discuss the informagion required for us to perform an independent confirmatory ASME Code stress "analysis of a sample piping system.

Prior to the meeting, the NRC had been supplied with isometric drawings. of each main steam safety/

relief valve discharge line.

During the morning, representatives of Pennsylvania Power and Light Company (PPSL),

NRC, Bechtel, and Pacific Northwest Labs (PNL) toured Units 1 5 2 to view various piping systems.

During the afternoon session, we stated that we would soon be able to choose a sample piping system for which PNL would perform an independent confirmatory ASME Code stress analysis.

Bechtel described some difficulties

/'t had encountered in modelling the SRV discharge piping and suggested a

simpler piping system might be more tractable.

We stated that this would be considered in making -obr choice.

We emphasized that the purpose of this analysis was not to attempt to duplicate Bechtel's ca1culations, but to independently verify that the sample piping system meets the appropriate ASME Code stress allowables.

A format was agreed to for submitting certain piping design information.

Enclosure Attendance List cc w/enc1osure:

See next page ORgeaI Vgn88 >Y Randal M. Stephens Mechanical Engineer ing Branch Division of Systems Safety

~pg prarI..I r 5'~'I~ I r.'I< r, QpY M

B LH~BC/DP R 'gyg/LL YlÃarr.

l/ Q /80 1/ ~ /80 OFFICE P SURNAME OATE P a

NRC FORM 318 (9.76) NRCI'8 0240 AU.S. GOVERNMENT PRINTING OFFICE: 1979.289 369

t t:'

~

I I'

h P

jP/l;, q ",*~

I 0'

% ~

~

Hr. Norman W. Curtis Vice President

- Engineering and Construction Pennsylvania Power and Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 JAN

~ 1980 CC:

Hr. Earle H. fiead Project Engineering Manager Pennsyl vani a Power

& Light Company 2 North Ninth Street Allentown, Pennsylvania 18101 Jay Silberg, Esq.

Shaw, Pittman, Potts Trowbridge 1800 M Street, N.

W.

Washington, D. C.

20036 Mr. William E. Barberich, Nuclear, Licensing Group Supervisor Pennsylvania Power

& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Edward H. Nagel, Fsquire General Counsel and Secretary Pennsylvania Power

& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Bryan Snapp, Esq.

Pennsylvania Power

& Light Company 901 Hamilton Street Al 1 entown, Pennsyl vani.a 18101 Robert H. Gallo Resident Inspector P. 0.

Box 52 Shickshinny, Pennsylvania 18655 Susquehanna Environmental Advocates c/o Gerald Schultz, Esq.

500 South Piver Street Wilkes-Barre, PA 18702 John L. Anderson Oak Ridge National Laboratory Union Carbide Corporation Bldg. 3500, P. 0.

Box X

Oak Ridge, Tennessee 37830 fir. Robert J. Shovlin Project Manager Pennsylvania Power and Light Co.

2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Matias F. Travieso-Diaz, Esq.

Shaw, Pittman, Potts Trowbridge 1800 M Street, N.

W.

Washington, D. C.

20036 Dr. Judith H. Johnsrud Co-Director Environmental Coalition on Nuclear Power 433 Orlando Avenue State College, PA 16801 Hr. Thomas M. Gerusky, Director Bureau of Radiation Protection Department of Environmental Resources Commonwealth of ?ennsylvania P. 0.

Box 2063 Harrisburg, PA 17120 Ms. Colleen Harsh Box 538A, RD44 Mountain Top, PA 18707 Mrs. Irene Lemanowicz, Chairperson The Citizens Against Nuclear Dangers P. 0.

Box 377 RD41 Berwic PA 18503

MEETING ATTENDEES NRC R. Stephens M. Hartzman R. Gallo, Res)dent Inspector PNL G.

Beeman D. Alzhefmer G. Marr PP&L C. Coddfngton 1<.

Rhoades T. Oldenhaje C. Beaulieu BECHTEL L. Shlpley H. Hkntz S.

Owen OFFICE/

SURNAME DATEP.

NRC FORM 318 (9 '/6) NRCM 0240 OU.S GOVERNMENT PAINTING OFFICE: 1979.289'309

1l I

l n ol'

PLANTS UNDER OL REVIEW 2.

3.

4, 5.

6.

7.

8.

Farley 2

Byron 1/2 Braidwood 1/2

.LaSalle 1/2

.Midland 1/2

'cGuire 1/2 So.

Texas 1/2 Shoreham 50-364 50-454, 455 50-456/457 50-373, 374 50-329,330 50-,369, 370 50-498, 499 50-322 9.

Waterford 10.

11.

12.

13.

14.

Summer 1

Grand Gulf 1/2 Diablo Canyon 1/2 Susquehana 1/2 Salem 2

50-382 50-416/417 50-275, 323 50-387 388 50-31 50-395 15.

16.

17.

18.

19.

20.

21.

San Onofre 2/3 Bellefonte 1/2 Natts"Bar 1/2 Seguoyah 1/2 Comanche Peak 1/2 North Anna 2

WPPSS-2 50-361, 362 50-438, 439 50-390, 391 50-327, 328 50-445, 446 50-339 50-397 22.

Fermi 2

23.

Zimmer 1

50-341 50-358

l h