Q ~ Lola REQULA INFORMATION DISTR IBUTI'0
'YSTEM (R IDS)
,ACCESSION NBR:8605160048 DOC. DATE: 86/05/05 NQTARIZED:
NQ DOCNET 0 FACIL:50-271 Vermont Yankee Nuclear Power Stationi Uermont Yankee 05000271 AUTH. NAME AUTHOR AFFILIATION MURPHY'. P Uermont Yankee Nuclear Potuer Corp.
REC IP. NAME RECIPIENT AFFILIATION RQQNEYi V. L.
BMR Prospect Directorate 2
SUBJECT:
Responds to Qeneric Ltr 86M4I "Policy Statement on Engineeering Expertise on Shift. "No specific eqvivalencg criteria established for shift engineer.
No changes to shift technical advisor program anticipated at present.
DISTRIBUTION CODE:
NCOSD COPIES RECEIVED: LTR L ENCL Q SIZE:
TITLE: Operator Requalification Program NOTES:
REC IP IENT ID CODE/NAME BNR PD2 PD COPIES REC IPlENT LTTR ENCL GODET ME 1
COPIES LTTR ENCL INTERNAL. NRR/DHFT/HFIB REC FILE 04 EXTERNAL: 24X NRC PDR NRR/DHFT/MTB RQN1 LPDR NSIC 03 05 TOTAL NUMBER OF COPIES REQUIRED'TTR 10 ENCL 48
r ERMONT YANKEE NUCLEAR POWER CORPORATION v)r RD 5, Box 169, Ferry Road, Brattleboro, VT05301 FVY 86-39 REPLY TO:
ENGINEERING OFFICE 1671 WORCESTER ROAD FRAMINGHAM,MASSACHUSETTS 01701 TELEPHONE 817-872-8100 Hay 5, 1986 U.S. Nu'clear.Regulatory Commission Washington, D.C.
20555 Attn:
Office of Nuclear Reacto r Regulation Yern L. Rooney, Sr. Project Manager BWR Project Directorate No.
2 Division of BWR Licensing
References:
a) b)
License No.
OPR-28 (Docket No. 50-271)
- Letter, USNRC to All Power Reactor Licensees and Applicants for Power Reactor Licenses, NVY 86-39, dated 2/13/86, Generic Letter 86-04
Dear Sir:
Subject:
Policy Statement on Engineering Expertise On Shift (Generic Letter 86-04)
Generic Letter 86-04, dated February 13, 1986 [Reference b)] provided a
copy of the Federal
~Re inter notice of the Policy Statement on Engineering Expertise on Shift and requested that Licensees respond with information con-cerning their present status and future plans regarding the options addressed in the Policy Statement.
In response to the three specific information requests contained in the Generic Letter, Vermont Yankee herein provides the following:
1.
"Your current program for providing engineering expertise on shift"
RESPONSE
Vermont Yankee assigns one Shift Engineer (SE) to each operating crew who then rotates with that crew.
The Shift Engineer reports to the Shift Supervisor (SS) while on duty and to the Senior Operations Engineer when not performing shift duties.
Currently, each Shift Engineer has a Bachelor's Degree in an engineering discipline and has received at least 12 weeks of initial plant training at Vermont Yankee before becoming qualified.
The training program, as specified in VY Procedure AP 0713, Shift Engineer Training, consists of Sb05160048 860505 PDR ADOCK 05000271 PDR
+05
]8
VERMONTYANKEENUCL AR POWER CORPORATION U.S. Nuclear Regulatory Commission May 5, 1986 Page 2
training in Reactor Theory, Chemistry, Nuclear Materials, Thermal Sciences, Instrumentation, FireProtection, Health Physics, Process
- Computer, Emer-gency Plan, Plant Systems, Transient and Accident Analysis, and Recognition
,and Mitigation of core'amage.
Fire brigade and fire fighting training is also included for each Shift Engineer since the SE is assigned as the Fire Brigade Commander.
Once qualified, each SE participates in an annual requalification training program which includes transient and accident analysis as well as simulator training.
2.
"If your current STA program utilizes 'equivalency'riteria to an engi-neering degree, provide a description of the criteria used"
RESPONSE
Vermont Yankee's "STA" has been given the title "Shift Engineer" (SE).
In accordance with Technical Specifications, Vermont Yankee SE's qualitica-tions are specified as "a bachelor's degree or equivalent in a scientific or "engineering discipline with specific training in plant design, and response and analysis of the plant for transients and accidents."
Vermont Yankee has not established specific equivalency criteria.
Any situation involving equivalency would be evaluated on a case-by-case basis.
3.
"A description of any modifications you intend to propose to your current program in, order to take advantage of the options identified in the Commission's Policy Statement"
RESPONSE
We anticipate no changes in our current program at this time.
We trust that the information provided above is responsive;
- however, should you have any questions or r equire additional information, please contact us.
/dm cc:
Mr. F.
Rowsome Oivision of Human Factors Technology U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Very truly yours, VERMONT YANKEE NUCLEAR POWER CORPORATION Afc~~ +wag Vice President and Manager of Operations
I
~
f