Supplemental Deficiency Rept Re Anchor Darling Valve Yokes. Condition Continues to Be Tracked Under Mcar 1-59.Final Rept Will Be Forwarded by Jan 1981,after Completion of Manufacturer Testing
ML18030A443
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 10/02/1980
From: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
PLA-551, NUDOCS 8010100337
Download: ML18030A443 (2)


Text

REGULA Y INFORMATION DISTRIBUTIO YSTEH (RIDS)

ACCESSION NBR:8010100337 DOC ~ DATE: 80/10/02 NOTARIZED: NO DOCKET ¹ FACIL:50 387 Susquehanna Steam Electric Station~ Unit iF Pennsylva 0500 50-388 Susquehanna Steam Electric Station> Jnit 2R Pennsylva 00 88 AUTH ~ NAHE AUTHOR AFFILIATION CURTISF N ~ n ~ Pennsylvania Power 8 Lignt Co.

REC IP ~ NAIVE RECIPIENT AFFILIATION GRIER p B ~ H ~ Region 1< Philadelohia< Office of the Director

SUBJECT:

Supplemental deficiency rept re Anchor Darling Valve Yokes.

Condition continues to. be tracked under VICAR 1 59 'inal rept will be forwarded by Jan 1981iafter completion of manufacturer testing, DISTRIBUTION CODE: B019S COPIKS RECEIVED:LTR g ENCL 4 SIZE:~

TITLE: Construction Deficiency Report (10CFRSO ~ 55E)

NOTES:Send ICE 3 copies FSAR 8 all amends'5000387 OS000388 RECIPIENT COPIES RECIPIENT COP IKS

'8 ID CODE/NAME, LTTR ENCL IO CODE/NA~E LTTR ENCL ACTION: A/0 LICENSNG 04 YOUNGBLOODRB 05 RUSHBROOK HE 06 STARKERS 07 INTERNAL: AD/RC I/IE 17 AEOD ASLBP/J,HARD D/DIR HUi4l FAC15 EDO 8 STAFF 19 EQUIP QUAL BR 11, HVO/GEO BR 22 ILE 09 LIC QUAL BR 12 MPA 20 NRC PDR 02 OKLD 21 P ST REV 13 QA BR R G F IL 01 RUTHERFORDgA ~ IE DEV 21 EXTKRNAL: ACRS ib 16 1 LPDR 03 NSIC 08 1 CT g 4 tg~~

0 TOTAL NUNSER OF COPIES REQUIRED: LTTR I//Q ENCL /4

0 TWO NORTH NINTH STREET, ALLENTOWN, PA. 18101 PHONEi (215) 821-5151 NORMAN 'W. CURTIS Vice Presiceni- Engineering 8, Ccnsiructicn. Nuclear 82 I-538 I October 2, 1980 Mr. Boyce H. Grier Director, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION STATUS UPDATE OF DEFICIENCY ON ANCHOR DARLING VALVE YOKES ERs 1004)0/100508 FILE 840-4/900-10 PLA-551

Reference:

PLA-511 dated July 21, 1980 PLA-505 dated July 7, 1980

Dear Mr. Grier:

This letter serves to supplement the above referenced correspondence which advised the Commission of the deficiency involving cracked valve yokes. The condition continues to be tracked under Bechtel's MCAR 1-59.

PP&L has been advised that the final report on the condition will be delayed pending comT3letion of Anchor Darling's NDE testing of suspect valve yokes.

Thus we expect to provide our final report under the provisions of 10CFR50.55(e) by January, 1981.

Very truly yours>

N. W. Curtis Vice President-Engineering 6 Construction-Nuclear FLW:mcb cc: Mr. Victor Stella (15)

Director-Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. G. McDonald, Director Office of Management Information U. S. Nuclear Regulatory Commission a Program Control Pdlf Hash'rgton, D.C.

Mr. Robert M. Gallo 20555 SrO U. S. Nuclear Regulatory Commission P.O. Box 52 Shickshinny, PA 18655 PENNSYLVANIA POWER 8 LIGHT COMPANY ao 3.oooo>37