Qgrg PP-I'-

',.,t! FII$ MP~

Docket Nos. 50>>3 7 388 f

FROf4!

DISTRIBUTION:

DEC 04 >98O Docket File 50-387

~Mocket File 50-388 ETSB Reading File ETSB Docket Files WEKreger/CSPaul l1EY10RANOUN FOR!

Edward S. Christenbury, Director and Chief Counsel Hearing Division, OELD Hill)am E. Kreger, Assistant Director for Radiation Protection,

OSI, NRR SUBJECT<

SUSQUEHANNA STEAN ELECTRIC STATION, CONTENTION l6 (COOLING TOWER DISCHARGE)

Enclosed is a statement of qualifications and the Affidavit of Charles L. Hillep.

regarding Contention 16.

4 OriginBl Bigoed bg'illiam Z. Kreger, William E. Kreger, Assistant Director for Radiation Protection Division of Systems Integration Office of Nuclear Reactor Regulation

Enclosures:

As stated cc:

M. P. Gati)l, DSI R. L. Tedesco, OL B. D. Youngblood, DL R. H. Stark, DL J.

H. Lavertg, OELD R. L. Bangart, DSI C. A. Hi'ilis, DSI C. L. fliller, DSI gig j /R02 ZS

......DS.l:.RP....

.....DS I.:.RP.;.EISB..

......HPBdim8.1.1...

12/ 0 /80 oFFrcc c

.05l: P..':SB

...M '.: ISH..

.....RL angar t....

.....1.u.93rro....

..~do....

.l<EKreger..

....1.2J..200 SuRNAMF-1 DATE c 12(g4J34g NRC Form 318B l4 79) NRCM 0240

  • U,C, COVCRNMCNT I'RINTINC ORNICCI 1444 44> 44

AFFIDAVIT OF CHARLES LEE MILLER I, Charles Lee Miller, being duly sworn, dispose and state:

Q:

By whom are you employed, and describe the work you performs A:

I am employed by the Effluent Treatment Systems Branch, Division of Systems Integration, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission.

A copy of my professional qualifications is attached to this affidavit.

Have you read "Applicants'otion for Summary Disposition of Contention 16 (Cooling Tower Discharge)", filed October 27, 1980, and thedocuments attached

thereto, including the affidavit of Walter J. Rhoadesl A:

Yes.

Q:

Would you describe the scope of the subject matter addressed in your affidavit2 A:

I have been asked to determine if cooling.towers at nuclear power plants normally constitute a radioactive release pathway to the environment.

I have also been asked to denote any devices or methods that may be used to determine the presence of radioactivity in the cooling tower water.

Is the cooling tower evaporate considered a source of radioactive release in your determination of plant radioactive effluent source terms'

A:

No, because cooling tower water at this facility under normal operation is not radioactive (Affidavit of Howard B. Holz at 2).

Additionally, the NRC Staff has not found the cooling tower evaporate to be radioactive in operating plants under normal conditions and thus it has not been identified as an effluent release pathway in BWRs.

The NRC Staff uses the BWR-GALE (Boiling Water Reactor - Gaseous and Liquid Effluent (NUREG-0016, Revision I)) computer code to calculate plant radio-active effluent source terms.

"Source terms" are the radionuclide species and their quantities that comprise the liquid 'arid gaseous effluents.from the plant during ~ormal: operations 'including anticipated'-'oper'ational

'o'ccurr'ences.

The computer code identifies the effluent waste streams in boiling water reactors and calculates the estimate of the quantities of radioactive efflu-ents that will be released.

The water systems that supply the cooling towers are not identified as effluent streams in the code.

What is the basis of the BMR-GALE computer codex':

The BMR-GALE computer code is used by the NRC Staff to help determine con-formance to 10 CFR Part 50, Appendix I. It is a mathematical model that calculates the release of radioactive mat'erials in gaseous and liquid A

effluents and is based on the best available data.

This data is generated from operating reactors, field tests, laboratory tests, and plant specific design considerations incorporated to reduce quantities of radioactive materials released to the environment.

The liquid effluent waste streams identified by the GALE code are consistent with those identified in ANSI N197-1976, "American National Standard BWR Liquid Radioactive Waste Process System."

The source terms calculated in tho GALE code are based on:

(a) standardized coolant activities derived from the ANS 18.1 Working Group; (b) release and transport mechanisms that result in radioactive materials appearing in liquid and gaseous waste streams; (c) plant specific design features to reduce radioactive materials released; and (d) information received from operating plants on radio'active waste stream characteristics and Haste treatment equipment'performan'ce.

Are there any ways to detect if radioactive material is in the cooling tower water2 Yes.

Although no radioactivity is expected in the service water system, a service water monitor is located in the downstream side of the fuel pool heat exchangers prior to discharge to the cooling tower as a pro-tection device.

The monitor is'a scintillation detector with a range from 10 to 10 counts per second.

An alarm is sounded if the radiation level is above background.

The objective of the monitor is

/

to detect radioactive material leakage to tPe service water from any source.

In addition, the cooling tower blowdown will be sampled periodically for r adioactivity.

Based on the above-mentioned considerations, I conclude that:-the cooling towers at 'Susquehanna will not'rovide a pathway for radioactivity. releases to the environment.

I hereby certify that the above statements are true and correct to the best of my knowledge and belief.

ar es Lee Mi er

CHARLES LEE MILLER Professional ualifications Division of S stems Inte ration Of sce o

Nuc ear Reactor Re u ation R

C My name is Charles Lee Miller.

I am currently employed by the U.S. Nuclear Regulatory Commission as a Nuclear Engineer, Effluent Treatment Systems

Branch, Division of Systems Integration, Office of Nuclear Reactor Regulation.

As such, my duties include participation in safety and environmental r eviews associated with licensing actions involving the design and operation of radioactive waste treatment systems of nuclear reactor power plants.

I received a

PhD in Chemical Engineering from the University of Maryland in August of 1974 and a Masters Degree in Chemical Engineering from the University of Maryland in August of 1971.

In May of 1968, I received a B.S. in Engineering from Widener College.

I am a Registered Professional Engineer (District. of Columbia).

In 1974, I joined Bechtel Power Corporation in the Gaithersburg, Maryland Office as a chemical engineer in their nuclear staff.

I was involved in the review,

design, evaluation and selection of systems and components used for treatment of radioactive wastes.

I also was responsible for performing Thermal-Hydraulic analysis for Loss of Coolant Accidents.

In 1976, I joined Science Applications, Inc., located in McLean, Virginia, as a senior engineer.

My responsibilities included evaluation of Nuclear Waste Disposal Alternatives, Nuclear Facility Safeguards, and Alternative Reprocessing Schemes for Nuclear Fuel.

I have held my position with the Commission since April 1980.

C

.s ~'4 Ab'C PS igloo rr