Interim Deficiency Rept Re Use of Stress Isometrics to Locate Supports.Condition Which Involves Use of Uncontrolled Sketches for Performing Const Activities Constitutes Breakdown in QA Program
ML18030A104
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 05/20/1980
From: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
To:
References
840-4-900-10, NUDOCS 8005280584
Download: ML18030A104 (3)


Text

P >li REGULATORY INFORMATION DISTRIBUTION SYSTEH (RIOS)

ACCESSION NBR:8005280584 OOC ~ DATE: 80/05/20 NOTARIZED: NO DOCKET ¹ FAC ' usauehanna Steam Electric Stationi Unit 1E Pennsylva 05000387 50 38 usauehanna Steam Electric StationE Unit 2E Pennsylva 05000388 A T ~ AUTHOR AFFILIATION CURTIS,>>.", Pennsylvania Power 8 light Co, REC IP ~ NAT'lE REC IP IENT AFFILIATION

SUBJECT:

Interim deficiency rept re use of stress isometr ics to locate supports'ondition which involves use of uncontrolled sketches for oerformance constr activities constitutes breakdown in QA program, DISTRIBUTION CODE: BOI90 COPIES RECEIVED:LTR ENCL + SIZE:~

TITlE: Construction Deficiency Report (10CFRSO ~ SSE)

NOT ES: ~~~> W <<X 4 &C~ M+8Z ~BC. CR&a2X~

REC I P IEN T COP I ES RECIPIENT COP IES IO CODE/NA'~Z LTTR ENCL IO CODE/NAME LTTR ENC 4CTIO>>: 14 PM Wf++4 1 15 BC C.MW +3 1 1 20 LA LCcPR 4B 1 21'O LWQ 1 1 INTERNAL: 0 1 02 NRC POR 1 1 05 I 8"E 2 07 EDO 8 STAFF 1 1 08 ~PA 09 DEPY OIR OPM 10 QAB 13F IFLD COOR/ IE 1

1 1

ll 16 STANOROS AO FOR OEV ENGR 1

1 1

1 1

1 17 AD PLANT SYS 1 17 AD REAC SFTY 1 ~

1 22 OIR DPI~ 1 23 GELD 1 1 AO/RCI/IE 1 AD/SI TE TECH 1 1 AEOO 1 DIRECTOR OSE 1 GEOSC IENCES 8R 1 HANAUERES ~ 1 l IKC SYS BR 1 ISA TL EIVG 8R 1

>BEECH EVG BR 1 POWER SYS SR 1 STRUCT ENG 8R 1

<EXTERNAL: 03 LPOR 1 04 NSIC 24 ACRS 16 1 h1AY 29 1980 TOT AL>>UT'>HER OF CUP IES REQUIRED: L TTR 48 ENCL

TWO NORTH NINTH STREET, ALLENTOWN, PA. 18101 PHONE: (215) 821-5151 NORMAN W. CURTIS Vice President. Engineering IL Construction 82 I-5381 May 20, 1980 Mr. Boyce H. Grier Director, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION NOTIFICATION OF A REPORTABLE DEFICIENCY REGARDING THE USE OF STRESS ISOMETRICS TO LOCATE SUPPORTS ERs 100450/100508 FILE 840-4/900-10 PLA-486

Dear Mr. Grier:

This letter serves to confirm information provided by telephone to NRC Inspector Mr. R. Gallo by Mr. A. R. Sabol of PPaL on January 25, 1980.

During that conversation, Mr. Gallo was advised that the sub)ect condition was under evaluation for reportability under the provisions of 10CFR50.55(e).

The deficiency involves the use of stress isometric sketches to locate pipe supports and has been documented in Bechtel MCAR 1-44. PP&L has determined that the condition which involves the use of uncontrolled sketches for perform-ing construction related activities constitutes a breakdown in Bechtel's cpxality assurance program.

Bechtel has agreed to clarify their Engineering Procedures Manual as PPGL advised the NRC in'our PLA-460 of March 17, 1980 which was in response to an Infraction transmitted by NRC Inspection Report No. 50-387/79<<41 and 50-388/79-22.

The inspection report identified the use of uncontrolled stress isometrics in the final inspections of pipe supports.

PPiilL and Bechtel are continuing to pursue an acceptable corrective action plan and will provide same when it becomes available.

Since the details of this report provide information relevant to the reporting requirements of 10CFR21, this correspondence is considered to also discharge any formal responsibility PP&L may have for reporting in compliance thereto.

S"~, 0 5 0052 80 6 II PENNSYLVANIA POWER IL LIGHT COMPANY

Mr. Boyce H. Grier May 20'980 We expect to issue a final report on this deficiency by August, 1980.

Very truly yours, N. W. Curtis Vice President-Engineering a Construction ARS:mcb cc: Mr. Victor Stello (15)

DirectorWffice of Inspection a Enforcement U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. G. McDonald, Director Office of Management information & Progxam Control U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr.. Robert M. Gallo U. S. Nuclear Regulatory Commission P 0 Box 52 Shickshinny, Pennsylvania 18655