Informs of Plan to Replace Stainless Steel Piping During Spring 1985 Major Maint & Refueling Outages as Part of Solution to Igscc.Requests That NRC Confirm Acceptability of Plan,Based on Section III of 1983 Edition ASME Code
ML18029A168
Person / Time
Site: Browns Ferry 
Issue date: 10/09/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8410150197
Download: ML18029A168 (6)


Text

REGULATORY *NFORMATION DISTRIBUTION SY~ t'EM (RIDS)

ACCESSION NBR: 8410150197 DOC ~ DATE: 8(i/10/09 NOTARIZED:

YES FACIL:50-259 Browns Ferry Nuclear Power Stations Unit 1, Tennessee AUTH'AME AUTHOR AFFILIATION MILLS',M, Tennessee Yalley Authority REC IP ~ NAME RECIPIENT AFFILIATION DENTONgH,RE Office of Nuclear Reactor Regulationi Director DOCKET 05000259 sIzE:

E2t

SUBJECT:

Informs of plan to r epl ace stainless steel piping during Spr in'985 maJor maint 8 refueling autages as pait of solution to IGSCC.Requests that NRC confirm acceptability of plan<based on Section III of 1983 Edition ASME Code

~

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR ENC TITLE:

OR Submittal: Inservice Inspection/Testing NOTES:NMSS/FCAF

1cy, 1cy NMSS/FCAF/PM'L:06/26/73 05000259 RECIPIENT ID CODE/NAME NRR ORB2 BC 01 INTERNAL: ADM/LFMB NRR/DE/MEB 15 NRR/DL/TAPMG RGN2 COPIES LTTR ENCL 7

7 1

0 1

1 1

1 1

1 RECIPIENT ID CODE/NAME ELD/HDSO N

TEB 14 EG F

LE 04 COPIES LTTR ENCL 1

0 1

1 1

EXTERNAL" ACRS NRC PDR NTIS NOTES:

16 10 10 02 1

1 1

1 LPDR NSIC 03 05 1,

1 1

1 TOTAL NUMBER OF COPIES REQUIRE,D:

LTTR 30 ENCL 28

pi%:y t

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 3740t 400 Chestnut Street Tower II October 9, 1984 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Denton:

In the Matter of the

)

Tennessee Valley Authority

)

Docket No. 50-259 As part of the solution to intergr anular stress corrosion cracking, we are planning to replace stainless steel piping on the Browns Ferry Nuclear Plant unit 1 during the spring 1985 ma)or maintenance and refueling outage.

This is to inform you that the installation and inspection of the replacement piping is being designed in accordance with Section III of the 1983 Edition ASME Code, Summer 1983 Addenda.

This has been discussed with R. J. Clark of your staff.

On September 27,

1984, we were informed that the NRC staff has found the above referenced ASME Section IIIedition and addenda to be acceptable for use and plans to eventually endorse it in 10 CFR Part 50.55a.

Therefore, we will continue with our plans for the replacement piping work based on the above referenced code.

We request that you please confirm the acceptability of this code in writing to TVA.

If you have any questions, please get in touch with us through the Browns Ferry Pro)ect Manager.

Ver y truly yours,

.X Subscribe sworn to me is day of I

'ota Public My Commission Expires r

cc:

See page 2

TENNESSEE VALLEY AUTHORITY L. M. Mills, M nager Nuclear Licensing 1984.

cy7 841009 BOloiS0~970>000Z59 PDR gDOCK

@DR P

J An Equal Opportunity Employer

I 4

4 4

~I ti tl I

I 54 I

I 4

~

C tf 4 N

I E',C ri 4

V"' tf1 C'k C

4,

Mr. Harold R. Benton October 9, 1984 cc:

U.S. Nuclear Regulatory Commission Region XI ATTN:

James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr.

R. J. Clark Browns Ferry Project; Manager U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue

Bethesda, Maryland 20814

t' 1

4